BISC209/F13: Lab3: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
Line 144: Line 144:
<BR>
<BR>


1. Use sterile serological pipets to make 12 mls of a 10-3 dilution of your soil extract.  You will need 12 ml (10 ml for the plate and 2 ml extra) of this working solution for each BIOLOG™ECO plate in order to inoculate all the wells. Our goal is to end up with about 10<sup>5</sup> cfu in each well. Pipet 10.8 mL of 10mM phosphate buffer into a large sterile tube and add 1.2 mL from the serial dilution that gave you 10<sup>3</sup>CFUs/ ml. <BR><BR>
1. Use sterile serological pipets to make 12 mls of a 10<sup>-3</sup> dilution of your soil extract.  You will need 12 ml (10 ml for the plate and 2 ml extra) of this working solution for each BIOLOG™ECO plate in order to inoculate all the wells. Our goal is to end up with about 10<sup>5</sup> cfu in each well. Pipet 10.8 mL of 10mM phosphate buffer into a large sterile tube and add 1.2 mL from the serial dilution that gave you 10<sup>3</sup>CFUs/ ml. <BR><BR>
2. If you will be using a multichannel micropipet to inoculate your BIolog plate, pour this 12ml of diluted soil extract into a sterile reservoir (a  petri dish or a v-shaped plastic reservoir). If the multichannel pipet is unavailable, forget pouring the soil extract dilution into a reservoir. You can use your P200 to dispense 100μL individual aliquots directly into each well of the BioLog plate as described in the next step.<BR><BR>
2. If you will be using a multichannel micropipet to inoculate your BIolog plate, pour this 12ml of diluted soil extract into a sterile reservoir (a  petri dish or a v-shaped plastic reservoir). If the multichannel pipet is unavailable, forget pouring the soil extract dilution into a reservoir. You can use your P200 to dispense 100μL individual aliquots directly into each well of the BioLog plate as described in the next step.<BR><BR>
3. Be careful to preserve the BIOLOG Eco™ plate's and its cover's sterility (eg. don't place it face down on your bench). Remove the cover and transfer 100µl of the soil extract dilution into each each well of the 96 well BIOLOG plate or use a multichannel pipet with new tips set to 100μL.  If you are using the multichannel pipet,  check visually the consistency of the amount of diluted extract in each of the micropipet tips after you have drawn up your aliquots to determine that you have no bubbles and that the quantity to be dispensed is the same. If the pipet tips appear unevenly filled or you have bubbles, do not dispense the inoculum into the wells! Expel the fluid back into the reservoir and start over. If you are unfamiliar with the use of multichannel pipets, ask your instructor to observe your technique. <BR><BR>
3. Be careful to preserve the BIOLOG Eco™ plate's and its cover's sterility (eg. don't place it face down on your bench). Remove the cover and transfer 100µl of the soil extract dilution into each each well of the 96 well BIOLOG plate or use a multichannel pipet with new tips set to 100μL.  If you are using the multichannel pipet,  check visually the consistency of the amount of diluted extract in each of the micropipet tips after you have drawn up your aliquots to determine that you have no bubbles and that the quantity to be dispensed is the same. If the pipet tips appear unevenly filled or you have bubbles, do not dispense the inoculum into the wells! Expel the fluid back into the reservoir and start over. If you are unfamiliar with the use of multichannel pipets, ask your instructor to observe your technique. <BR><BR>