#Lately, I've been carrying out this procedure using a multichannel pipettor to speed steps up. I use a P50 multichannel pipettor to add 20μL water to the appropriate number of wells in a 96 well plate/ Picking colonies is essentially the same except that I inoculate the colony into a 96 well plate rather than a tube. The PCR is carried out in 8 tube strips rather than individual tubes. After adding 9.5μL of the primer + PCR supermix master mix to each PCR tube, I transfer 1μL of colony-water mixture to the reaction tube using a P10 multichannel pipettor. (I transfer 1 μL rather than 0.5μL because it is easier to pipette.) I then touch spin the PCR tube strips in a rack using a swinging bucket rotor in order to collect the contents of the tube to the bottom. The PCR conditions are the same. --[[Reshma Shetty | RS]] |