User:Paul Rothenberg/Notebook/Pauls Notebook/2013/06/19: Difference between revisions
From OpenWetWare
(fix raw html notebook nav) |
|||
(3 intermediate revisions by 2 users not shown) | |||
Line 2: | Line 2: | ||
|- | |- | ||
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span> | |style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span> | ||
|style="background-color: #F2F2F2" align="center"| | |style="background-color: #F2F2F2" align="center"|[[File:Report.png|frameless|link={{#sub:{{FULLPAGENAME}}|0|-11}}]][[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|[[File:Resultset_previous.png|frameless|link={{#lnpreventry:{{FULLPAGENAME}}}}]][[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]] }}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]][[File:Resultset_next.png|frameless|link={{#lnnextentry:{{FULLPAGENAME}}}}]]}} | ||
|- | |- | ||
| colspan="2"| | | colspan="2"| | ||
Line 12: | Line 12: | ||
<b>Data:</b> | <b>Data:</b> | ||
[[Image:Mb_Acetate_OPD_H2O2_Acetone_WORKUP_Trial2_GRAPH.bmp]] | [[Image:Mb_Acetate_OPD_H2O2_Acetone_WORKUP_Trial2_GRAPH.bmp|750px]] | ||
[[Image: | [[Image:Mb_Acetate_OPD_H2O2_Acetone_GRAPH_Trial3.png|750px]] | ||
[[Image:Mb_Phosphate_OPD_H2O2_Acetone_WORKUP_Trial2_GRAPH.bmp|750px]] | |||
[[Image:Mb_Phosphate_OPD_H2O2_Acetone_WORKUP_Trial3_GRAPH.bmp|750px]] | |||
The data we've been collecting has not been consistent. But, I think there could be a reason for this: when the protein solutions are removed from the sonicator, everything collects at the bottom nearly immediately. To counteract this, it can be shaken and then immediately added, but even then, the amount of protein being added to the reaction has not been consistent, most likely. Compare any of the trials, and there may not have been the exact same concentration of protein in the reactions. | The data we've been collecting has not been consistent. But, I think there could be a reason for this: when the protein solutions are removed from the sonicator, everything collects at the bottom nearly immediately. To counteract this, it can be shaken and then immediately added, but even then, the amount of protein being added to the reaction has not been consistent, most likely. Compare any of the trials, and there may not have been the exact same concentration of protein in the reactions. |
Latest revision as of 22:46, 26 September 2017
Project name | Main project page Previous entry Next entry |
Reaction of OPD+H2O2 with Mb Phosphate and Acetate Catalysts in Acetone SuspensionDhea and I are continuing the trials of the suspension reactions. We are going to continue Acetone and finish up the trials tomorrow. Data: The data we've been collecting has not been consistent. But, I think there could be a reason for this: when the protein solutions are removed from the sonicator, everything collects at the bottom nearly immediately. To counteract this, it can be shaken and then immediately added, but even then, the amount of protein being added to the reaction has not been consistent, most likely. Compare any of the trials, and there may not have been the exact same concentration of protein in the reactions.
|