User:Bohao Liu/Notebook/Research/2014/04/30: Difference between revisions

From OpenWetWare
< User:Bohao Liu‎ | Notebook‎ | Research‎ | 2014‎ | 04
Jump to navigationJump to search
(3 intermediate revisions by the same user not shown)
Line 6: Line 6:
| colspan="2"|
| colspan="2"|
<!-- ##### DO NOT edit above this line unless you know what you are doing. ##### -->
<!-- ##### DO NOT edit above this line unless you know what you are doing. ##### -->
==HOG Experiments : wild - type controls==
==HOG Experiments : wild - type controls and Image Analysis Parameters==




Line 22: Line 22:
====Settings====
====Settings====
*30 second half-period
*30 second half-period
*5 second imaging = 6 images per cycle
*6 second imaging = 6 images per cycle
*5 minute total time = 5 complete periods
*5 minute total time = 5 complete periods
*30 minutes in between for a total of 5 sets
*1 hour rest after this set of 5
*30 second half-period
*6 second imaging = 6 images per cycle
*20 minute total time = 20 complete periods


*ND=2
*ND=2
Line 30: Line 37:
*DIC
*DIC


====Image Analysisp====
*for windows sorting :
**<code>for /l %x in (1,1,5) do MD well%x</code>
**<code>for /l %x in (1,1,5) do MOVE col*t*xy%xc*.tif well%x</code>





Revision as of 11:30, 30 April 2014

Project name <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>

HOG Experiments : wild - type controls and Image Analysis Parameters

Objective

  • Make sure I can do HOG experiments again
  • Confirm Wild-type values and also expand the frequencies tested
  • Confirm the protocol: specifically that waiting 30 minutes between each set of oscillations is enough to ensure that the cells return to normal
  • See if the cells are growing

Experiment

  • Cells OD @ 10 = .453
  • Started flow at 10:45 am
  • Started experiment at 11:15 am

Settings

  • 30 second half-period
  • 6 second imaging = 6 images per cycle
  • 5 minute total time = 5 complete periods
  • 30 minutes in between for a total of 5 sets
  • 1 hour rest after this set of 5
  • 30 second half-period
  • 6 second imaging = 6 images per cycle
  • 20 minute total time = 20 complete periods
  • ND=2
  • mCherry = 200 mS exposure
  • GFP = 200 mS exposure
  • DIC


Image Analysisp

  • for windows sorting :
    • for /l %x in (1,1,5) do MD well%x
    • for /l %x in (1,1,5) do MOVE col*t*xy%xc*.tif well%x