User:Jacob Esenther/Notebook/581/2014/10/03

From OpenWetWare
< User:Jacob Esenther‎ | Notebook‎ | 581‎ | 2014‎ | 10
Jump to: navigation, search
BDLlogo notext lr.png Biomaterials Design Lab Report.pngMain project page
Resultset previous.pngPrevious entry      Next entryResultset next.png



Objective

  • Began new PVA and PVA-Clay films (an extra PVA-Clay film is being produced)
  • Began new ion-exchanged clays


Description

  1. New Standard Films
    1. Protocol may be viewed here.
  2. Began new ion-exchanged clays
    1. Exchange following Dr. Harting's procedure. The ion we are using is tributylhexadecylphosphonium bromide.

Data

  • New Standard Films
    • 0.11151g clay + 1.00047g PVA
    • 0.11463g clay + 1.00168g PVA
    • 1.00733g PVA
  • Diffusion Results
    • 0.54118g MG+Film

Notes

Don't attempt to vacuum filter foam out of clay, it destroys it