<!-- sibboleth --><div id="lncal1" style="border:0px;"><div style="display:none;" id="id">lncal1</div><div style="display:none;" id="dtext"></div><div style="display:none;" id="page">User:Melissa Novy/Notebook/CHEM-571/2012/11/27</div><div style="display:none;" id="fmt">yyyy/MM/dd</div><div style="display:none;" id="css">OWWNB</div><div style="display:none;" id="month"></div><div style="display:none;" id="year"></div><div style="display:none;" id="readonly">Y</div></div>

BDLlogo 300.png <sitesearch>title=Search this Project</sitesearch>

Customize your entry pages <html><img src="/images/a/aa/Help.png" border="0" /></html>

Objectives

  • Analyze solutions of AuHRP and AuADA, both made on 2012/11/14 with UV-vis.
  • Make solutions of AuADA with dialyzed ADA.
    • ADA dialysis began on 2012/11/14 and ended on 2012/11/27.
    • Please refer to Keyun Wang's entry for the procedure used to remove the ADA from the dialysis tubing and prepare it for use in AuADA solutions.

UV-Vis on AuHRP and AuADA

  • Exactly 3 mL of each solution was pipetted into a quartz cuvette for analysis using an automated pipetter (Pipetman).
  • Please refer to Dhea Patel's entry for photographs of the solutions.
  • Observations:
    • Small pellets of fibers were visible in all AuHRP solutions except 60 AuHRP. The 60 AuHRP solution did not contain a fiber pellet. All AuHRP solutions were purple in color.
    • AuADA solutions were colorless and contained no aggregates.

UV-Vis Spectra of AuADA 11142012.JPG

  • The spectra for all solutions displayed a peak at around 520 nm, which indicates the presence of GNPs. The general trend was that the absorbance of these peaks increased as the mole ratio of Au:HRP increases. This implies that the amount of GNPs in solution increased in accordance with the amount of gold initially added to each solution.
  • However, the peak absorbances for the 130 and 140 AuHRP solutions were almost identical. This is likely because the 130 AuHRP solution contained 1 mL less of H2O due to an error during preparation of the solution.

UV-Vis Spectra of AuADA.JPG

Synthesizing AuADA Solutions

  • Please refer to the protocol on 2012/11/14. There were no deviations from the protocol and the same stock solution of HAuCl4 was used. However, dialyzed ADA was used instead of ADA in FPLC elution buffer.
  • Please refer to Keyun Wang's entry for observations made during the procedure.