*Used to determine reaction completion (based on the change in the peaks)
 
*Used to determine reaction completion (based on the change in the peaks)
 
[[Image:2012 1009 ZnPPPIX abs.PNG]]
 
[[Image:2012 1009 ZnPPPIX abs.PNG]]
 +
No visible change in peaks between 'ZnPPIX#2 100x' (dark blue line- the second sample of refluxing ZnPPIX taken) and 'ZnPPIX after' (light blue line- the final sample taken when reflux was stopped), used to determine that the reaction was complete.<br.>
 
Peaks consistent with the literature: largest peak at ~500nm, next largest at ~600nm, smallest peak at ~550nm.
 
Peaks consistent with the literature: largest peak at ~500nm, next largest at ~600nm, smallest peak at ~550nm.
  

Revision as of 07:31, 16 October 2013

Owwnotebook icon.png ZnPPIX Synthesis <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>

October 9, 2013

Procedures

  • Synthesize new ZnPPIX with Dr Hartings
  • Procedure adapted from "On the preparation of metalloporphyrins"
    • 0.5g tetraphenylporphyrin refluxed in 50mL DMF
    • 0.403g (stiochiometric amount) zinc acetate added, solution refluxed until reaction complete
      • completion determination by unchanged peaks in UV-vis measurements
    • 50mL distilled water added, solution chilled and then filtered
      • the filtrate was filtered over again and added to main filtered sample

Data

Absorbance Measurements

  • Used to determine reaction completion (based on the change in the peaks)

2012 1009 ZnPPPIX abs.PNG No visible change in peaks between 'ZnPPIX#2 100x' (dark blue line- the second sample of refluxing ZnPPIX taken) and 'ZnPPIX after' (light blue line- the final sample taken when reflux was stopped), used to determine that the reaction was complete.<br.> Peaks consistent with the literature: largest peak at ~500nm, next largest at ~600nm, smallest peak at ~550nm.

Notes

Next time:

  • Dissolve filtered ZnPPIX in DMF