Difference between revisions of "User:Keyun Wang/Notebook/Experimental Biological Chemistry I/2013/03/26"

From OpenWetWare
Jump to: navigation, search
(Autocreate 2013/03/26 Entry for User:Keyun_Wang/Notebook/Experimental_Biological_Chemistry_I)
 
 
Line 1: Line 1:
 
{|{{table}} width="800"
 
{|{{table}} width="800"
 
|-
 
|-
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span>
+
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Experimental Biological Chemistry II</span>
 
|style="background-color: #F2F2F2" align="center"|<html><img src="/images/9/94/Report.png" border="0" /></html> [[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>[[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]]<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>}}
 
|style="background-color: #F2F2F2" align="center"|<html><img src="/images/9/94/Report.png" border="0" /></html> [[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>[[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]]<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>}}
 
|-
 
|-
 
| colspan="2"|
 
| colspan="2"|
 
<!-- ##### DO NOT edit above this line unless you know what you are doing. ##### -->
 
<!-- ##### DO NOT edit above this line unless you know what you are doing. ##### -->
==Entry title==
+
==Purpose==
* Insert content here...
+
* Determine the amount of silver particle that leaks out of film throughout time via silver electrode conducting experiment
  
 +
==Procedure==
 +
* From 100Ag-LMT film made on [[User:Melissa Novy/Notebook/CHEM-572/2013/03/05|2013/03/05]], three of 0.5g of film in round form were cut out.
 +
* 50mL of pure water were poured into a polypropylene beaker as control. In three separate polypropylene beakers, one film was placed in each beaker, respectively.
 +
* Conductivity measurements in mV were measured for every 30 minutes for a total of 2 hours.
 +
* The conductivity were recorded and plotted.
 +
 +
==Results==
 +
* The conductivity measurements were recorded below.
 +
{| {{table}}
 +
| align="center" style="background:#f0f0f0;"|'''Initial [Ag<sup>+</sup>] [M]'''
 +
| align="center" style="background:#f0f0f0;"|'''Final [Ag<sup>+</sup>] [M]'''
 +
| align="center" style="background:#f0f0f0;"|'''log [Ag<sup>+</sup>] []'''
 +
| align="center" style="background:#f0f0f0;"|'''Conductivity [mV]'''
 +
| align="center" style="background:#f0f0f0;"|''''''
 +
| align="center" style="background:#f0f0f0;"|''''''
 +
| align="center" style="background:#f0f0f0;"|'''Average Conductivity [mV]'''
 +
| align="center" style="background:#f0f0f0;"|'''Standard Deviation [mV]'''
 +
| align="center" style="background:#f0f0f0;"|'''Corrected Conductivity [mV]'''
 +
|-
 +
| ||||||Trial 1||Trial 2||Trial 3||||||
 +
|-
 +
| 0||0||---||341.9||340.2||335.6||339.2333333||3.259345538||0
 +
|-
 +
| 0.000001||9.80392E-07||-6.008600172||328.3||329.6||331||329.6333333||1.350308607||-9.6
 +
|-
 +
| 0.00001||9.80392E-06||-5.008600172||328.5||330.6||329.4||329.5||1.053565375||-9.733333333
 +
|-
 +
| 0.0001||9.80392E-05||-4.008600172||357.2||359.2||359.5||358.6333333||1.250333289||19.4
 +
|-
 +
| 0.001||0.000980392||-3.008600172||417.6||417.1||416.6||417.1||0.5||77.86666667
 +
|-
 +
| 0.01||0.009803922||-2.008600172||472.8||473.3||473.6||473.2333333||0.404145188||134
 +
|-
 +
| 0.1||0.098039216||-1.008600172||527.2||527.5||528||527.5666667||0.404145188||188.3333333
 +
|}
 +
 +
[[Image:Ag%2B_Calibration_Curve_3-26-2013.jpg]]
  
 
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->
 
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->

Latest revision as of 19:51, 31 March 2013

Owwnotebook icon.png Experimental Biological Chemistry II <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html>      </html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>

Purpose

  • Determine the amount of silver particle that leaks out of film throughout time via silver electrode conducting experiment

Procedure

  • From 100Ag-LMT film made on 2013/03/05, three of 0.5g of film in round form were cut out.
  • 50mL of pure water were poured into a polypropylene beaker as control. In three separate polypropylene beakers, one film was placed in each beaker, respectively.
  • Conductivity measurements in mV were measured for every 30 minutes for a total of 2 hours.
  • The conductivity were recorded and plotted.

Results

  • The conductivity measurements were recorded below.
Initial [Ag+] [M] Final [Ag+] [M] log [Ag+] [] Conductivity [mV] ' ' Average Conductivity [mV] Standard Deviation [mV] Corrected Conductivity [mV]
Trial 1 Trial 2 Trial 3
0 0 --- 341.9 340.2 335.6 339.2333333 3.259345538 0
0.000001 9.80392E-07 -6.008600172 328.3 329.6 331 329.6333333 1.350308607 -9.6
0.00001 9.80392E-06 -5.008600172 328.5 330.6 329.4 329.5 1.053565375 -9.733333333
0.0001 9.80392E-05 -4.008600172 357.2 359.2 359.5 358.6333333 1.250333289 19.4
0.001 0.000980392 -3.008600172 417.6 417.1 416.6 417.1 0.5 77.86666667
0.01 0.009803922 -2.008600172 472.8 473.3 473.6 473.2333333 0.404145188 134
0.1 0.098039216 -1.008600172 527.2 527.5 528 527.5666667 0.404145188 188.3333333

Ag+ Calibration Curve 3-26-2013.jpg