==UV-Vis Limit of Detection For Salts== | ==UV-Vis Limit of Detection For Salts== | ||
'''To find the limit of detection for the 10mM salts(Fe<sub>2</sub>(SO<sub>4</sub>)<sub>3</sub>, Al<sub>3</sub>(SO<sub>4</sub>)<sub>3</sub>, FeSO<sub>4</sub>, & Na<sub>2</sub>SO<sub>4</sub>) originally prepared 10/26/12, UV-Vis was run for each salt at various volumes added to a prepared porphyrin solution. A total of 16 solutions were prepared.''' | |||
Solution of 1.89 μM porphyrin | |||
(94.45 μM)(V<sub>1</sub>)=(1.89 μM)(10mL) | |||
V<sub>1</sub> = 0.2mL of 94.45 μM porphyrin | |||
{| {{table}} | |||
| align="center" style="background:#f0f0f0;"|'''Porphyrine''' | |||
| align="center" style="background:#f0f0f0;"|'''Al<sub>2</sub>(SO<sub>4</sub>)<sub>3</sub> concentration''' | |||
| align="center" style="background:#f0f0f0;"|'''Fe<sub>2</sub>(SO<sub>4</sub>)<sub>3</sub> concentration''' | |||
| align="center" style="background:#f0f0f0;"|'''FeSO<sub>4</sub> concentration''' | |||
| align="center" style="background:#f0f0f0;"|'''Na<sub>2</sub>SO<sub>4</sub> concentration''' | |||
| align="center" style="background:#f0f0f0;"|'''Volume of Water Added [mL]''' | |||
|- | |||
| 1.89 µM||1 mM||1 mM||1 mM||1 mM||9.9 | |||
|- | |||
| 1.89 µM||2 mM||2 mM||2 mM||2 mM||9.8 | |||
|- | |||
| 1.89 µM||5 mM||5 mM||5 mM||5 mM||9.5 | |||
|- | |||
| 1.89 µM||10 mM||10 mM||10 mM||10 mM||9 | |||
|} | |||
==UV-Vis Spectrums: 1.89μM Porphyrin Solution w/ Varied Salts & Salt Concentrations== | ==UV-Vis Spectrums: 1.89μM Porphyrin Solution w/ Varied Salts & Salt Concentrations== |
Revision as of 11:29, 30 November 2012
PVOH Research | <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page <html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html> </html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html> | ||||||||||||||||||||||||||||||
OBJECTIVES
UV-Vis Limit of Detection For SaltsTo find the limit of detection for the 10mM salts(Fe2(SO4)3, Al3(SO4)3, FeSO4, & Na2SO4) originally prepared 10/26/12, UV-Vis was run for each salt at various volumes added to a prepared porphyrin solution. A total of 16 solutions were prepared. Solution of 1.89 μM porphyrin (94.45 μM)(V1)=(1.89 μM)(10mL) V1 = 0.2mL of 94.45 μM porphyrin