|style="background-color: #F2F2F2" align="center"| | |style="background-color: #F2F2F2" align="center"|[[File:Report.png|frameless|link={{#sub:{{FULLPAGENAME}}|0|-11}}]][[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|[[File:Resultset_previous.png|frameless|link={{#lnpreventry:{{FULLPAGENAME}}}}]][[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]] }}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]][[File:Resultset_next.png|frameless|link={{#lnnextentry:{{FULLPAGENAME}}}}]]}} | ||
|- | |- | ||
| colspan="2"| | | colspan="2"| | ||
Line 14: | Line 14: | ||
** the solution is certified by ICP (ion couple plasma spectroscopy) to NIST SRM 3121 | ** the solution is certified by ICP (ion couple plasma spectroscopy) to NIST SRM 3121 | ||
For the AAS (atomic absorption Spectrometer), the published detection limit for gold is 0.2 ppm ( a 1% absorbance)for this instrument. recent | For the AAS (atomic absorption Spectrometer), the published detection limit for gold is 0.2 ppm ( a 1% absorbance) for this instrument. recent experiments put the detection limit closer to 2 ppm for gold, and since 20 ppm is roughly 0.1 mM Au, therefore I created standards ranging from 5 to 40 ppm. | ||
For reference the molecular weight of gold is 197 g/mol. | |||
* created 50 mL of each standard: 5, 8, 10, 15, 20, 25, 30, 40 ppm Au | * created 50 mL of each standard: 5, 8, 10, 15, 20, 25, 30, 40 ppm Au |
Latest revision as of 22:06, 26 September 2017
CHEM571 | Main project page Previous entry Next entry | |||||||||||||||||||
Objective
Bench Work
For the AAS (atomic absorption Spectrometer), the published detection limit for gold is 0.2 ppm ( a 1% absorbance) for this instrument. recent experiments put the detection limit closer to 2 ppm for gold, and since 20 ppm is roughly 0.1 mM Au, therefore I created standards ranging from 5 to 40 ppm. For reference the molecular weight of gold is 197 g/mol.
Data/Spectra
Notes
|