BME103:T130 Group 7 l2: Difference between revisions
Line 124: | Line 124: | ||
'''PCR Protocol''' | '''PCR Protocol''' | ||
Polymerase Chain Reaction | |||
To amplify samples of DNA, the OpenPCR machine was used to perform a Polymerase Chain Reaction (PCR). This technique worked by cycling a mixture of DNA Template, Primers, Taq Polymerase, Magnesium Chloride, and dNTP's through three specific temperatures to create more copies of the desired sequence. After assembling the PCR mixture, the PCR machine was programmed to perform three stages. In the first stage, the samples went through one cycle at 95⁰C for 3 minutes. The purpose of this stage was to initially denature the DNA and allow the primers to act on the DNA. The second stage put the samples through 35 cycles of 95⁰C, 57⁰C, and 72⁰C each for 30 seconds. The purpose of the first part of the second stage is to break apart the hydrogen bonds between the base pairs, denaturing the DNA sequence into two separate strands. The purpose of the low temperature is to allow primers to bind. The purpose of the middle temperature is to create an environment for Taq Polymerase to assemble a new strand that is the desired product of the entire polymerase chain reaction. The last stage, stage three, puts the samples through one cycle of 72⁰C for 3 minutes. There is a final hold of 4⁰C that preserves the DNA. The samples were then taken out of the PCR machine. The target sequence had been amplified a million times and could now be analyzed with less sensitive equipment! To analyze the sequence, see the Fluorimeter section. | <br> | ||
To amplify samples of DNA, the OpenPCR machine was used to perform a Polymerase Chain Reaction (PCR). This technique worked by cycling a mixture of DNA Template, Primers, Taq Polymerase, Magnesium Chloride, and dNTP's through three specific temperatures to create more copies of the desired sequence. After assembling the PCR mixture, the PCR machine was programmed to perform three stages. In the first stage, the samples went through one cycle at 95⁰C for 3 minutes. The purpose of this stage was to initially denature the DNA and allow the primers to act on the DNA. The second stage put the samples through 35 cycles of 95⁰C, 57⁰C, and 72⁰C each for 30 seconds. The purpose of the first part of the second stage is to break apart the hydrogen bonds between the base pairs, denaturing the DNA sequence into two separate strands. The purpose of the low temperature is to allow primers to bind. The purpose of the middle temperature is to create an environment for Taq Polymerase to assemble a new strand that is the desired product of the entire polymerase chain reaction. The last stage, stage three, puts the samples through one cycle of 72⁰C for 3 minutes. There is a final hold of 4⁰C that preserves the DNA. The samples were then taken out of the PCR machine. The target sequence had been amplified a million times and could now be analyzed with less sensitive equipment! To analyze the sequence, see the Fluorimeter section. | |||
Revision as of 15:18, 28 November 2012
BME 103 Fall 2012 | Home People Lab Write-Up 1 Lab Write-Up 2 Lab Write-Up 3 Course Logistics For Instructors Photos Wiki Editing Help | ||||||
OUR TEAMLAB 2 WRITE-UPThermal Cycler EngineeringOur re-design is based upon the Open PCR system originally designed by Josh Perfetto and Tito Jankowski.
ProtocolsMaterials
Thermal Cycler for PCR reaction
Supplied by User Sterile gloves PCR Protocol Polymerase Chain Reaction
DNA Measurement Protocol Research and DevelopmentBackground on Disease Markers
Primer Design
Illustration
|