User:Karlena L. Brown/Notebook/PVOH Research/2012/10/19: Difference between revisions
From OpenWetWare
(fix raw html notebook nav) |
|||
(2 intermediate revisions by one other user not shown) | |||
Line 2: | Line 2: | ||
|- | |- | ||
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> PVOH Research</span> | |style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> PVOH Research</span> | ||
|style="background-color: #F2F2F2" align="center"| | |style="background-color: #F2F2F2" align="center"|[[File:Report.png|frameless|link={{#sub:{{FULLPAGENAME}}|0|-11}}]][[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|[[File:Resultset_previous.png|frameless|link={{#lnpreventry:{{FULLPAGENAME}}}}]][[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]] }}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]][[File:Resultset_next.png|frameless|link={{#lnnextentry:{{FULLPAGENAME}}}}]]}} | ||
|- | |- | ||
| colspan="2"| | | colspan="2"| | ||
Line 38: | Line 38: | ||
==Atomic Absorption NaMT-CuSO4 Exchanged Filtrate Solutions== | ==Atomic Absorption NaMT-CuSO4 Exchanged Filtrate Solutions== | ||
'''RECALL ATOMIC ABSORPTION PROCEDURAL PROTOCOL 10/02/12''' | |||
'''Atomic Absorption Data and Calibration Curve Data from AA wizard:''' | |||
{| {{table}} | {| {{table}} | ||
| align="center" style="background:#f0f0f0;"|'''''' | | align="center" style="background:#f0f0f0;"|'''''' | ||
Line 104: | Line 108: | ||
==Crosslinking Porphyrin Films== | ==Crosslinking Porphyrin Films== | ||
RECALL PROTOCOL REGARDING CROSSLINKING GLUTALDEHYDE FILMS 9/21/12; however, pay attention to the two PVOH films that will not be placed in the fixant solution during the crosslinking procedure. | '''RECALL PROTOCOL REGARDING CROSSLINKING GLUTALDEHYDE FILMS 9/21/12'''; however, pay attention to the two PVOH films that will not be placed in the fixant solution during the crosslinking procedure. | ||
{| {{table}} | {| {{table}} |
Latest revision as of 22:17, 26 September 2017
PVOH Research | Main project page Previous entry Next entry | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
OBJECTIVES
New CuSO4 Dilution Standards for Atomic Absorption
(20 ppm CuSO4)V1 = (0.1 ppm CuSO4)(12mL) V1 = 0.6mL of 20 ppm CuSO4
(20 ppm CuSO4)V1 = (0.5 ppm CuSO4)(12mL) V1 = 1.2mL of 20 ppm CuSO4
(20 ppm CuSO4)V1 = (1 ppm CuSO4)(12mL) V1 = 3mL of 20 ppm CuSO4
(20 ppm CuSO4)V1 = (2 ppm CuSO4)(12mL) V1 = 6mL of 20 ppm CuSO4
(20 ppm CuSO4)V1 = (3 ppm CuSO4)(12mL) V1 = 9mL of 20 ppm CuSO4 Using the following concentrations(shown above), a calibration curve was prepared.
Atomic Absorption NaMT-CuSO4 Exchanged Filtrate SolutionsRECALL ATOMIC ABSORPTION PROCEDURAL PROTOCOL 10/02/12 Atomic Absorption Data and Calibration Curve Data from AA wizard:
Fixant Solution Preparation
(Actual Na2SO4 Mass: 199.9953g)
Crosslinking Porphyrin FilmsRECALL PROTOCOL REGARDING CROSSLINKING GLUTALDEHYDE FILMS 9/21/12; however, pay attention to the two PVOH films that will not be placed in the fixant solution during the crosslinking procedure.