Tasks
- Prepare 500 mL stock solution of 50 mM NaCl
- 1 L stock buffer solution of 50 mM glycine
- Prepare a 25 mL solution of 1 g/L lysozyme
- set up 5 lysozyme dyalisis experiments:
- 4.0 mL of the prepared lysozyme solution beaker filled with a 50 mM NaCl stock solution. Using a 3500 g/mol MWCO tubing
- 4.0 mL of the prepared lysozyme solution in beaker filled with a 50 mM glycine stock solution. Using a 3500 g/mol MWCO tubing
- 4.0 mL of the prepared lysozyme solution in beaker filled with 50 mM glycine stock solution. Using a 25k g/mol MWCO tubing
- 4.0 mL of the 35.6:1 [Au]:[lys] solution in beaker filled with 50 mM glycine stock solution. Using a 3500 g/mol MWCO tubing
- 4.0 mL of the prepared lysozyme solution in a beaker filled with H2O. Using a 3500 g/mol MWCO tubing
- 4.0 mL of the prepared lysozyme solution in a 50 mM glycine solution. Using a 15k g/mol MWCO tubing
|