User talk:Rebeca Rodriguez/Notebook/581/2014/10/01: Difference between revisions
(→Data) |
(→Data) |
||
Line 53: | Line 53: | ||
==Data== | ==Data== | ||
===Fluorescents=== | |||
0.0120g of R6G in 10mL needed to make a 2500uM stock solution. | 0.0120g of R6G in 10mL needed to make a 2500uM stock solution. | ||
Line 68: | Line 71: | ||
|- | |- | ||
| 2||0.004 | | 2||0.004 | ||
|} | |||
{| {{table}} | |||
| align="center" style="background:#f0f0f0;"|'''Exitation Wavelength''' | |||
| align="center" style="background:#f0f0f0;"|'''500 nm''' | |||
|- | |||
| Range||515nm -700nm | |||
|- | |||
| Slit Width||10nm | |||
|- | |||
| Scan Speed||200 nm/min | |||
|} | |} | ||
Revision as of 06:26, 1 October 2014
Biomaterials Design Lab | <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page | ||||||||||||||||||||
ObjectiveTwo groups will be working on determining fluorophore concentration. (Alicia/Madeleine and Becky/Eleni/Melvin) The other two groups will be working on diffusion. (Jake/James/Mary and Andrew/Michael/Tami). NOTE: The groups working on fluorophores will need to space to the groups working on diffusion as their research is very time sensitive. DescriptionFluorescence
Diffusion
DataFluorescents0.0120g of R6G in 10mL needed to make a 2500uM stock solution.
NotesThis area is for any observations or conclusions that you would like to note.
|