==Entry title==
+
==gel electrophoresis==
-
* Insert content here...
+
* The aim of this lab is to determine the sex of the rainbow lorikeets through agar gel electrophoresis. Gel is 2% agar and stained with GelGreen that has been sitting on my desk room temperature since last test (which was successful). I will run a ladder as well to make sure that the gel is still showing luminescence.
 +
If the PCR failed, I expect the DNA not to migrate. I am loading 5ul DNA sample with 1ul x 6x DNA running buffer (glycerol + bromophenol blue).
 +
 +
Samples were loaded as follows:
 +
*1SWWBD
 +
*2SWWBD
 +
*R5#9
 +
*Ladder (300-10KB)
 +
*R5#51
 +
*R5#52
 +
*R5#100
 +
*Pink Gold
 +
 +
Gel ran at 100V (intially started at 300V for a few seconds and then pansied out) and 60mA. Immediate illumination could be seen in the well with the ladder. Gel is running and I can see the ladder but nothing else. Fuck. Looks like I am going back to PCR. After 300bp had reached centre, still no light from samples. Maybe run a single lorikeet sample through PCR and then check on a gel.
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->

Current revision

Project name Main project page
Previous entry      Next entry

gel electrophoresis

  • The aim of this lab is to determine the sex of the rainbow lorikeets through agar gel electrophoresis. Gel is 2% agar and stained with GelGreen that has been sitting on my desk room temperature since last test (which was successful). I will run a ladder as well to make sure that the gel is still showing luminescence.

If the PCR failed, I expect the DNA not to migrate. I am loading 5ul DNA sample with 1ul x 6x DNA running buffer (glycerol + bromophenol blue).

Samples were loaded as follows:

  • 1SWWBD
  • 2SWWBD
  • R5#9
  • Ladder (300-10KB)
  • R5#51
  • R5#52
  • R5#100
  • Pink Gold

Gel ran at 100V (intially started at 300V for a few seconds and then pansied out) and 60mA. Immediate illumination could be seen in the well with the ladder. Gel is running and I can see the ladder but nothing else. Fuck. Looks like I am going back to PCR. After 300bp had reached centre, still no light from samples. Maybe run a single lorikeet sample through PCR and then check on a gel.