[[Image:Mb_Phosphate_Isopropanol_Suspension_GRAPH.png]] | [[Image:Mb_Phosphate_Isopropanol_Suspension_GRAPH.png|750px]] | ||
The absorbances are not consistently increasing, like they were last week. Even after centrifuging, the results are not consistent. The peaks are all over, and the reference peak is much higher. That, however, is probably due to the reference not being centrifuged. Otherwise, the centrifuged times were not consistently increasing or decreasing. | The absorbances are not consistently increasing, like they were last week. Even after centrifuging, the results are not consistent. The peaks are all over, and the reference peak is much higher. That, however, is probably due to the reference not being centrifuged. Otherwise, the centrifuged times were not consistently increasing or decreasing. | ||
Line 20: | Line 20: | ||
Same procedure and reaction,but with Mb/Acetate and 20 minute intervals, not 15 minutes. | Same procedure and reaction,but with Mb/Acetate and 20 minute intervals, not 15 minutes. | ||
<b>1:50</b> The reaction was started. The reaction was run for two hours, looking at the Mb/Phosphate results. 120 Minutes had the highest absorbance out of any time. | <b>1:50</b> The reaction was started. The reaction was run for two hours, looking at the Mb/Phosphate results. 120 Minutes had the highest absorbance out of any time in the previous reaction. | ||
<b>Data</b> | |||
[[Image:Mb_Acetate_OPD_H2O2_Isopropanol_WORKUP_GRAPH.png|750px]] | |||
Again, the data is not consistently increasing in absorbance. The reference is again the highest absorbance, likely because it wasn't centrifuged. The absorbances were also more broad, compared to Friday's absorbances. | |||
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### --> | <!-- ##### DO NOT edit below this line unless you know what you are doing. ##### --> |
Revision as of 09:31, 8 July 2013
Project name | <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page <html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html> </html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html> |
Reaction of OPD+H2O2 with Mb/Phosphate Catalyst Suspended in Isopropanol
9:41: Reaction was started, will place in centrifuge and run for 10 minutes in 5 minutes. Continued 9 times (1 mL increments) up to 135 minutes Data: The absorbances are not consistently increasing, like they were last week. Even after centrifuging, the results are not consistent. The peaks are all over, and the reference peak is much higher. That, however, is probably due to the reference not being centrifuged. Otherwise, the centrifuged times were not consistently increasing or decreasing. Reaction of OPD+H2O2 with Mb/Acetate Catalyst Suspended in IsopropanolSame procedure and reaction,but with Mb/Acetate and 20 minute intervals, not 15 minutes. 1:50 The reaction was started. The reaction was run for two hours, looking at the Mb/Phosphate results. 120 Minutes had the highest absorbance out of any time in the previous reaction. Data Again, the data is not consistently increasing in absorbance. The reference is again the highest absorbance, likely because it wasn't centrifuged. The absorbances were also more broad, compared to Friday's absorbances. |