User:Paul Rothenberg/Notebook/CHEM 571 Fall 2014/2014/10/28: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
(fix raw html notebook nav)
 
Line 2: Line 2:
|-
|-
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span>
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span>
|style="background-color: #F2F2F2" align="center"|<html><img src="/images/9/94/Report.png" border="0" /></html> [[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>[[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]]<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>}}
|style="background-color: #F2F2F2" align="center"|[[File:Report.png|frameless|link={{#sub:{{FULLPAGENAME}}|0|-11}}]][[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|[[File:Resultset_previous.png|frameless|link={{#lnpreventry:{{FULLPAGENAME}}}}]][[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]][[File:Resultset_next.png|frameless|link={{#lnnextentry:{{FULLPAGENAME}}}}]]}}
|-
|-
| colspan="2"|
| colspan="2"|

Latest revision as of 00:28, 27 September 2017

Project name Main project page
Previous entry      Next entry

Continuation of Lysozyme vs KI Dialysis

I used the I- ISE probe to rerun concentration of I- in the dialysis solutions.

Results

Sample Potential (mV) ln[KI] [KI] (mM)
L-50 mM KI -253.7 3.014259251 20.37399334
L-25 mM KI -237.7 2.324990307 10.22658096
L-10 mM KI -215.8 1.38155344 3.981081197
L-5 mM KI -199.9 0.696592427 2.006902376
L-2 mM KI -177.4 -0.272692026 0.761327221
25 mM KI -240.1 2.428380649 11.34050295
10 mM KI -210.8 1.166156895 3.209633945
5 mM KI -196.2 0.537198983 1.711207024
2 mM KI -173.7 -0.432085469 0.649153892

Analysis of Lysozyme vs CaCl2 Dialysis

Monika and I reran this dialysis because the lysozyme crashed out. We ran Bradford, UV, Fluorescence, and Ca2+ ISE.

Results


Fluorescence:

Bradford:

UV-VIS:

NB - I had to rerun the 5 µM sample because the wavelength range was not correct on the first run on Wednesday. I also reran a stock and blank for comparison.