User:Paul Rothenberg/Notebook/CHEM 571 Fall 2014/2014/08/27: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
(fix raw html notebook nav)
 
(5 intermediate revisions by one other user not shown)
Line 2: Line 2:
|-
|-
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span>
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span>
|style="background-color: #F2F2F2" align="center"|<html><img src="/images/9/94/Report.png" border="0" /></html> [[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>[[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]]<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>}}
|style="background-color: #F2F2F2" align="center"|[[File:Report.png|frameless|link={{#sub:{{FULLPAGENAME}}|0|-11}}]][[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|[[File:Resultset_previous.png|frameless|link={{#lnpreventry:{{FULLPAGENAME}}}}]][[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]][[File:Resultset_next.png|frameless|link={{#lnnextentry:{{FULLPAGENAME}}}}]]}}
|-
|-
| colspan="2"|
| colspan="2"|
Line 19: Line 19:
Next, solutions were made with gold:protein ratios of 10:1 to 60:1. (See the table). The test tubes were placed in at 80°C for three hours, starting at 13:00.
Next, solutions were made with gold:protein ratios of 10:1 to 60:1. (See the table). The test tubes were placed in at 80°C for three hours, starting at 13:00.


==Kinetics==
{| class="wikitable"
0.5 mL of HAuCl<sub>4</sub> stock and 0.166 mL of Lysozyme stock were added to three test tubes for a 30:1 gold to protein ratio. 4.33 mL of 80°C water was added. Kinetics runs were done every 30 minutes with 2.5 mL of sample in plastic cuvette from 800-360 nm. Started at 13:35.
|-
 
! Au
==<font color=#0f1028></font>==
! Lysozyme
{|style="width:700px"
! H<sub>2</sub>O
|<u>Au</u>
|-
|<u>Lysozyme</u>
| 2.5 mL
|<u>H<sub>2</sub>O</u>
| 2.5 mL
| 0 mL
|-
|-
|2.5 mL
| 2.5 mL
|2.5 mL
| 1.25 mL
|0 mL
| 1.25 mL
|-
|2.5 mL
|1.25 mL
|1.25 mL
|-
|-
|2.5 mL
| 2.5 mL
|0.835 mL
| 0.835 mL
|1.665 mL
| 1.635 mL
|-
|-
|2.5 mL
| 2.5 mL
|0.625 mL
| 0.625 mL
|1.875 mL
| 1.875 mL
|-
|-
|2.5 mL
| 2.5 mL
|0.5 mL
| 0.5 mL
|2 mL
| 2 mL
|-
|-
|2.5 mL
| 2.5 mL
|0.415 mL
| 0.415 mL
|2.08 mL
| 2.08 mL
|-
|-
|}


<br>
==Kinetics==
0.5 mL of HAuCl<sub>4</sub> stock and 0.166 mL of Lysozyme stock were added to three test tubes for a 30:1 gold to protein ratio. 4.33 mL of 80°C water was added. Kinetics runs were done every 30 minutes with 2.5 mL of sample in plastic cuvette from 800-360 nm. Started at 13:35.


This was rerun. See [http://openwetware.org/wiki/User:Paul_Rothenberg/Notebook/CHEM_571_Fall_2014/2014/09/09 here] for the results.





Latest revision as of 00:12, 27 September 2017

Project name Main project page
Previous entry      Next entry

Making HAuCl4 and Lysozyme Stocks

  • Final [H+] wanted: 0.25 mM
  • Actual amount of HAuCl4: 0.04550 g
    • (slightly more water added to the volumetric flask)
  • Final [Lysozyme] wanted: 250 μM
  • Actual amount of Lysozyme:
  • 50 mL of 0.25 mM HCl was made as a control

Next, solutions were made with gold:protein ratios of 10:1 to 60:1. (See the table). The test tubes were placed in at 80°C for three hours, starting at 13:00.

Au Lysozyme H2O
2.5 mL 2.5 mL 0 mL
2.5 mL 1.25 mL 1.25 mL
2.5 mL 0.835 mL 1.635 mL
2.5 mL 0.625 mL 1.875 mL
2.5 mL 0.5 mL 2 mL
2.5 mL 0.415 mL 2.08 mL

Kinetics

0.5 mL of HAuCl4 stock and 0.166 mL of Lysozyme stock were added to three test tubes for a 30:1 gold to protein ratio. 4.33 mL of 80°C water was added. Kinetics runs were done every 30 minutes with 2.5 mL of sample in plastic cuvette from 800-360 nm. Started at 13:35.

This was rerun. See here for the results.