User:Monika Gasiorek/Notebook/CHEM-571 2014F/2014/10/15: Difference between revisions
From OpenWetWare
(Autocreate 2014/10/15 Entry for User:Monika_Gasiorek/Notebook/CHEM-571_2014F) |
|||
Line 6: | Line 6: | ||
| colspan="2"| | | colspan="2"| | ||
<!-- ##### DO NOT edit above this line unless you know what you are doing. ##### --> | <!-- ##### DO NOT edit above this line unless you know what you are doing. ##### --> | ||
== | ==October 15, 2014== | ||
=='''Tornado Warning'''== | |||
Disruptive... | |||
=='''Primary Experiment Dialysis #2 Work-up'''== | |||
'''30:1 colloid solution vs CaCl2 using MWCO 3500''' | |||
==<font color=#0f1028></font>== | |||
{|style="width:700px" | |||
|<u>'''Well 1'''</u> | |||
|<u>'''Well 2'''</u> | |||
|<u>'''Well 3'''</u> | |||
|<u>'''Well 4'''</u> | |||
|<u>'''Well 5'''</u> | |||
|- | |||
|30:1 colloid | |||
|30:1 colloid | |||
|30:1 colloid | |||
|30:1 colloid | |||
|30:1 colloid | |||
|- | |||
|50 mM CaCl<sub>2</sub> | |||
|5 mM CaCl<sub>2</sub> | |||
|0.5 mM CaCl<sub>2</sub> | |||
|50 μM CaCl<sub>2</sub> | |||
|5 μM CaCl<sub>2</sub> | |||
|- | |||
|} | |||
'''Necessary Analyses:''' | |||
*Bradford - completed, results need to be uploaded | |||
**5 colloid samples, 30:1 colloid reference, and Bradford blank | |||
**20 μL sample, 200 μL 1:4 Bradford, 780 μL 50 mM Tris/50 mM NaCl | |||
'''NOTE''': There was a bit of a struggle getting a reliable spectrum for the blank. Was run 3 times in order to average/verify. We also made the executive decision to run samples of 50 μL from now on (diluted with 200 μL Bradford and 750 μL Tris/NaCl) in order to increase the precision/accuracy of the results. | |||
*Fluorescence - not completed | |||
**5 colloid samples, 30:1 colloid reference | |||
**10 μL of sample in 990 μL of DI water | |||
*UV-Vis - not completed | |||
**5 colloid samples, 30:1 colloid reference | |||
**10 μL of sample in 990 μL of DI water | |||
*CaCl<sub>2</sub> ISE - not completed | |||
**All 10 samples | |||
=='''Primary Experiment Dialysis #3 Set-Up'''== | |||
'''0.6 g/L Lysozyme vs CaCl2 using MWCO 3500''' | |||
==<font color=#0f1028></font>== | |||
{|style="width:700px" | |||
|<u>'''Well 1'''</u> | |||
|<u>'''Well 2'''</u> | |||
|<u>'''Well 3'''</u> | |||
|<u>'''Well 4'''</u> | |||
|<u>'''Well 5'''</u> | |||
|- | |||
|0.6 g/L lysozyme | |||
|0.6 g/L lysozyme | |||
|0.6 g/L lysozyme | |||
|0.6 g/L lysozyme | |||
|0.6 g/L lysozome | |||
|- | |||
|50 mM CaCl<sub>2</sub> | |||
|5 mM CaCl<sub>2</sub> | |||
|0.5 mM CaCl<sub>2</sub> | |||
|50 μM CaCl<sub>2</sub> | |||
|5 μM CaCl<sub>2</sub> | |||
|- | |||
|} | |||
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### --> | <!-- ##### DO NOT edit below this line unless you know what you are doing. ##### --> | ||
|} | |} | ||
__NOTOC__ | __NOTOC__ |
Revision as of 20:16, 15 October 2014
Project name | <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page <html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html> </html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html> | ||||||||||||||||||||||||||||||
October 15, 2014Tornado WarningDisruptive... Primary Experiment Dialysis #2 Work-up30:1 colloid solution vs CaCl2 using MWCO 3500
Necessary Analyses:
NOTE: There was a bit of a struggle getting a reliable spectrum for the blank. Was run 3 times in order to average/verify. We also made the executive decision to run samples of 50 μL from now on (diluted with 200 μL Bradford and 750 μL Tris/NaCl) in order to increase the precision/accuracy of the results.
Primary Experiment Dialysis #3 Set-Up0.6 g/L Lysozyme vs CaCl2 using MWCO 3500
|