Line 45: | Line 45: | ||
| 3500 Gly/Coll Bag||2.82038835||0.155 | | 3500 Gly/Coll Bag||2.82038835||0.155 | ||
|} | |} | ||
[[Image:Bradford_Dialysis_Analysis.png|500px]] | |||
'''NOTE''': Negative concentrations of protein in the soak solutions may be a result of protein precipitation. | |||
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### --> | <!-- ##### DO NOT edit below this line unless you know what you are doing. ##### --> |
Revision as of 10:36, 28 September 2014
Project name | <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page <html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html> </html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html> | ||||||||||||||||||||||||||||||
September 24, 2014Bradford Analysis of DialysisA Bradford analysis was done on the dialysis samples prepared and dialyzed last week.
50 mM NaCl stock solution with 3500 g/mol MWCO tubing 50 mM Glycine stock solution with 3500 g/mol MWCO tubing Pure water with 3500 g/mol MWCO tubing 50 mM Glycine stock solution with 25k g/mol MWCO tubing 50 mM Glycine stock solution with 3500 g/mol MWCO tubing
NOTE: As mentioned previously, the contents of the tube in the fourth system (50 mM glycine solution with 25K g/mol MWCO tubing) were lost during transfer; thus, only four tubing samples are included in the results.
NOTE: Negative concentrations of protein in the soak solutions may be a result of protein precipitation. |