User:Monika Gasiorek/Notebook/CHEM-571 2014F/2014/09/09

From OpenWetWare
Jump to navigationJump to search
Project name <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>

September 9, 2014

Fluorescence Spectrum of Phenylalanine

A fluorescence spectrum of a 200 µM phenylalanine solution was obtained, in comparison to that of a water control sample.

Kinetics of AuNP Formation - Take 2

  • A 150 mL beaker containing approximately 100 mL of water was heated to 70°C.
  • 5 culture tubes were prepared each containing 0.5 mL of 2.512 mM HAuCl4, 0.167 mL of 2.512 x 10-4 M lysozyme, and 4.333 mL of H2O, giving a [Au]:[protein] of 30:1. The test tubes were covered with foil and placed in the beaker of 70°C water.
  • 2.5 mL of one sample was placed in a plastic cuvette at time point 0 hr, pre-heating, to set a baseline UV-Vis spectrum from 800 nm to 360 nm.
  • Another 2.5 mL aliquot of the samples was taken every 20 min. and a respective UV-Vis was recorded from 800 nm to 360 nm until no more sample solution remained.