User:Moira M. Esson/Notebook/CHEM-581/2012/11/16

From OpenWetWare

(Difference between revisions)
Jump to: navigation, search
(Entry title)
(UV-vis porhyrin films)
Line 11: Line 11:
#Test swelling on all crosslinked glutaraldehyde films
#Test swelling on all crosslinked glutaraldehyde films
==UV-vis porhyrin films==
==UV-vis porhyrin films==
-
 
+
General protocol for UV-vis on porphyrin films:
-
 
+
#Remove crosslinked porphyrin films from deionized H<sub>2</sub>O and pat dry using a paper towel
 +
#Using a quartz cuvette as a guide, cut a strip of paper the same width as the quartz cuvette.
 +
#Using the strip of paper as a guide and scissors(or a similar sharp instrument) carefully cut the porphyrin film the same width as the paper reference. When cutting the film, try and use a smooth portion of film.
 +
#Measure the thickness of the film. This will be used as the pathlength.
 +
#Using forceps, carefully place the cut strip of film in a clean quartz cuvette.
 +
#Using a spatula, gently press the film against the cuvette.
 +
#Carefully place the cuvette into the UV-vis.
 +
#Measure following the general protocol for   
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->

Revision as of 17:55, 26 November 2012

Project name Main project page
Previous entry      Next entry

Objectives

  1. Standardize sodium bicarbonate solution
  2. Run UV-vis on porphyrin films
  3. Test swelling on all crosslinked glutaraldehyde films

UV-vis porhyrin films

General protocol for UV-vis on porphyrin films:

  1. Remove crosslinked porphyrin films from deionized H2O and pat dry using a paper towel
  2. Using a quartz cuvette as a guide, cut a strip of paper the same width as the quartz cuvette.
  3. Using the strip of paper as a guide and scissors(or a similar sharp instrument) carefully cut the porphyrin film the same width as the paper reference. When cutting the film, try and use a smooth portion of film.
  4. Measure the thickness of the film. This will be used as the pathlength.
  5. Using forceps, carefully place the cut strip of film in a clean quartz cuvette.
  6. Using a spatula, gently press the film against the cuvette.
  7. Carefully place the cuvette into the UV-vis.
  8. Measure following the general protocol for