User:Michael S. Bible/Notebook/581/2014/10/17: Difference between revisions
(→Data) |
(fix raw html notebook nav) |
||
(2 intermediate revisions by one other user not shown) | |||
Line 2: | Line 2: | ||
|- | |- | ||
|style="background-color: #EEE"|[[Image:BDLlogo_notext_lr.png|128px]]<span style="font-size:22px;"> Biomaterials Design Lab</span> | |style="background-color: #EEE"|[[Image:BDLlogo_notext_lr.png|128px]]<span style="font-size:22px;"> Biomaterials Design Lab</span> | ||
|style="background-color: #F2F2F2" align="center"| | |style="background-color: #F2F2F2" align="center"|[[File:Report.png|frameless|link={{#sub:{{FULLPAGENAME}}|0|-11}}]][[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|[[File:Resultset_previous.png|frameless|link={{#lnpreventry:{{FULLPAGENAME}}}}]][[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]] }}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]][[File:Resultset_next.png|frameless|link={{#lnnextentry:{{FULLPAGENAME}}}}]]}} | ||
|- | |- | ||
| colspan="2"| | | colspan="2"| | ||
Line 19: | Line 19: | ||
==Description== | ==Description== | ||
To determine the concentration of the R6G solutions from the fluorescence spectra, Riemann sums were used to integrate the peaks. These peak integration values were then plugged into the equation of the fluorescence calibration curve for R6G that was created on [[User:Michael_S._Bible/Notebook/581/2014/10/08|10/08]] and the concentration was determined. To determine the original concentration before dilution, the concentration value given by the equation was then multiplied by the dilution factor. | |||
==Data== | ==Data== | ||
[[Image:Fluorescence_of_R6G-film_sample_solutions.png]] | [[Image:Fluorescence_of_R6G-film_sample_solutions.png]] | ||
[[Image:R6G_absorption_by_films..png]] | |||
==Notes== | ==Notes== |
Latest revision as of 00:26, 27 September 2017
Biomaterials Design Lab | Main project page Previous entry Next entry |
Analysis of R6G Experimental SolutionsIt was determined that the R6G stock solution that was used to create all of the solutions used in the experiment was mislabeled. It was originally believed to be 159 μM but |Madeleine and Alicia determined that the true concentration of the stock solution was 1.9 mM. Using the same calculation technique described on 9/24 the concentration of the three starting solutions were determined.
DescriptionTo determine the concentration of the R6G solutions from the fluorescence spectra, Riemann sums were used to integrate the peaks. These peak integration values were then plugged into the equation of the fluorescence calibration curve for R6G that was created on 10/08 and the concentration was determined. To determine the original concentration before dilution, the concentration value given by the equation was then multiplied by the dilution factor. DataNotesAdd notes here.
|