User:Michael S. Bible/Notebook/571/2014/10/15: Difference between revisions

From OpenWetWare
< User:Michael S. Bible‎ | Notebook‎ | 571‎ | 2014‎ | 10
Jump to navigationJump to search
(fix raw html notebook nav)
 
(3 intermediate revisions by one other user not shown)
Line 2: Line 2:
|-
|-
|style="background-color: #EEE"|[[Image:BDLlogo_notext_lr.png|128px]]<span style="font-size:22px;"> Biomaterials Design Lab</span>
|style="background-color: #EEE"|[[Image:BDLlogo_notext_lr.png|128px]]<span style="font-size:22px;"> Biomaterials Design Lab</span>
|style="background-color: #F2F2F2" align="center"|<html><img src="/images/9/94/Report.png" border="0" /></html> [[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>[[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]]<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>}}
|style="background-color: #F2F2F2" align="center"|[[File:Report.png|frameless|link={{#sub:{{FULLPAGENAME}}|0|-11}}]][[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|[[File:Resultset_previous.png|frameless|link={{#lnpreventry:{{FULLPAGENAME}}}}]][[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]][[File:Resultset_next.png|frameless|link={{#lnnextentry:{{FULLPAGENAME}}}}]]}}
|-
|-
| colspan="2"|
| colspan="2"|
Line 17: Line 17:
*Spectra data were integrated using Riemann sums of base 0.5 nm.
*Spectra data were integrated using Riemann sums of base 0.5 nm.


====Fluorescence of CaCl<sub>2</sub> Data====
====Fluorescence of CaCl<sub>2</sub>-Dialyzed Protein Data====


[[Image:Fluorescence_Responses_of_Calcium_binded_proteins.png]]
[[Image:Fluorescence_Responses_of_Calcium_binded_proteins.png]]
Line 23: Line 23:
In the image above, there is a clear and highly linear relationship between the peak integration and log[CaCl<sub>2</sub>] between 50 μM and 5 mM concentrations of CaCl<sub>2</sub>.  Additional tests should be done to determine if this is indeed the case and to see if the trend extends further in either direction.
In the image above, there is a clear and highly linear relationship between the peak integration and log[CaCl<sub>2</sub>] between 50 μM and 5 mM concentrations of CaCl<sub>2</sub>.  Additional tests should be done to determine if this is indeed the case and to see if the trend extends further in either direction.


==Description==
==Fluorescence Analysis of HCl-Dialyzed Lysozyme==
# Add experimental record here. Include what, how, and why...
 
*The Fluorescence Spectrometer was used to analyze the dialyzed Lysozyme and the solutions against which Lysozyme was dialyzed. 
*The instrument was set to an excitation wavelength of '''λ = 280 nm'''.
*Emission spectra were collected in the range of '''λ = 300-550 nm'''.
*Spectra data were integrated using Riemann sums of base 0.5 nm.
 
====Fluorescence of HCl-Dialyzed Protein Data====
 
[[Image:Concentration_of_HCl_versus_peak_integration_of_post-dialysis_HCl_soaks.png]]
 
In the image above, there is no clear relationship between the concentration of the HCl soak initially and its post-dialysis peak integration. 
 
[[Image:Concentration_of_HCl_versus_peak_integration_of_post-dialysis_protein_solutions.png]]
 
There appears to be a highly linear relationship between the peak integration values at HCl concentration of 250 μM, 125 μM, and 30 μM. More tests are necessary to see if this is indeed the case.


==Data==
==Data==

Latest revision as of 00:27, 27 September 2017

Biomaterials Design Lab Main project page
Previous entry      Next entry



Fluorescence Analysis of CaCl2-Dialyzed Lysozyme

  • The Fluorescence Spectrometer was used to analyze the dialyzed Lysozyme.
  • The instrument was set to an excitation wavelength of λ = 280 nm.
  • Emission spectra were collected in the range of λ = 300-550 nm.
  • Spectra data were integrated using Riemann sums of base 0.5 nm.

Fluorescence of CaCl2-Dialyzed Protein Data

In the image above, there is a clear and highly linear relationship between the peak integration and log[CaCl2] between 50 μM and 5 mM concentrations of CaCl2. Additional tests should be done to determine if this is indeed the case and to see if the trend extends further in either direction.

Fluorescence Analysis of HCl-Dialyzed Lysozyme

  • The Fluorescence Spectrometer was used to analyze the dialyzed Lysozyme and the solutions against which Lysozyme was dialyzed.
  • The instrument was set to an excitation wavelength of λ = 280 nm.
  • Emission spectra were collected in the range of λ = 300-550 nm.
  • Spectra data were integrated using Riemann sums of base 0.5 nm.

Fluorescence of HCl-Dialyzed Protein Data

In the image above, there is no clear relationship between the concentration of the HCl soak initially and its post-dialysis peak integration.

There appears to be a highly linear relationship between the peak integration values at HCl concentration of 250 μM, 125 μM, and 30 μM. More tests are necessary to see if this is indeed the case.

Data

  • Add data and results here...

Notes

This area is for any observations or conclusions that you would like to note.


Use categories like tags. Change the "Course" category to the one corresponding to your course. The "Miscellaneous" tag can be used for particular experiments, as instructed by your professor. Please be sure to change or delete this tag as required so that the categories remain well organized.