User:Michael F. Nagle/Notebook/Tattnauer Brinkman 3545M/2012/12/07: Difference between revisions
From OpenWetWare
(Autocreate 2012/12/07 Entry for User:Michael_F._Nagle/Notebook/Tattnauer_Brinkman_3545M) |
(fix raw html notebook nav) |
||
(5 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
{|{{table}} width="800" | {|{{table}} width="800" | ||
|- | |- | ||
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> | |style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Tattnauer Brinkman 3545M Autoclave</span> | ||
|style="background-color: #F2F2F2" align="center"| | |style="background-color: #F2F2F2" align="center"|[[File:Report.png|frameless|link={{#sub:{{FULLPAGENAME}}|0|-11}}]][[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|[[File:Resultset_previous.png|frameless|link={{#lnpreventry:{{FULLPAGENAME}}}}]][[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]] }}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]][[File:Resultset_next.png|frameless|link={{#lnnextentry:{{FULLPAGENAME}}}}]]}} | ||
|- | |- | ||
| colspan="2"| | | colspan="2"| | ||
<!-- ##### DO NOT edit above this line unless you know what you are doing. ##### --> | <!-- ##### DO NOT edit above this line unless you know what you are doing. ##### --> | ||
== | |||
* Insert | ==Description== | ||
[[Image:Au_to_clave.png]] | |||
*Tattnauer Brinkman 3545M | |||
*Tabletop autoclave | |||
==Purpose of Use== | |||
*Completely sterilize material with high temperature and pressure | |||
==Use== | |||
*Twist dial on bottom right corner to "Fill" and wait for water to fill up to the metal ridge near the door. | |||
*Insert the material that needs to be autoclaved. | |||
*Close the door and twist the door handle shut. | |||
*Set temperature and time | |||
*Turn knob to "sterilize" | |||
*Wait 30 minutes after sterilization is complete for pressure to reach 0psi, before openning autoclave. | |||
==Safety== | |||
*After autoclaving, wait until pressure dial is at 0psi before opening the autoclave. This takes about 30 minutes. | |||
==Specifications== | |||
*12.2" wide, 18.5" deep | |||
*3.25L refillable water reservoir | |||
*corrosion resistant chamber | |||
*exhaust options | |||
==Location== | |||
* Beeghly 314 | |||
==Contact== | |||
*contact with questions or to schedule access via email | |||
**[[User:Matt_Hartings|Dr. Matt Hartings]] | |||
**[[User:Abigail_E._Miller|Dr. Abigail Miller]] | |||