User:Melissa Novy/Notebook/CHEM-572/2013/02/12
From OpenWetWare
(Difference between revisions)
(Autocreate 2013/02/12 Entry for User:Melissa_Novy/Notebook/CHEM-572) |
(→Entry title) |
||
| Line 15: | Line 15: | ||
<!-- ##### DO NOT edit above this line unless you know what you are doing. ##### --> | <!-- ##### DO NOT edit above this line unless you know what you are doing. ##### --> | ||
| - | == | + | ==Objectives== |
| - | * | + | * Filter 100Ag-LMT (1 week), made on [[User:Melissa_Novy/Notebook/CHEM-572/2013/02/05|2013/02/05]]. |
| + | * Create a calibration curve for the determination of Ag<sup>+<sup> with a silver ion-selective electrode. Solutions of AgNO<sub>3</sub> and KNO<sub>3</sub> made on [[User:Melissa_Novy/Notebook/CHEM-572/2013/02/05|2013/02/05]] were used. | ||
| + | * Test [[User:Melissa_Novy/Notebook/CHEM-572/2013/01/30|reserved filtrate solution]] from 95Ag-LMT (24 h). | ||
| + | * Cells. | ||
| + | ==100Ag-LMT== | ||
| + | * Observations | ||
| + | ** During the week that the solution was stirring, the Laponite formed a thick, medium gray gel with the consistency of Neosporin. Half of the gel was reserved for further testing, and the other half was resuspended in (50:50) H<sub>2</sub>O/EtOH and filtered with 42 Whatman paper. The sample was covered with aluminum foil at all times to prevent photodamage to the silver. | ||
| + | |||
| + | ==Ag<sup>+</sup> Calibration Curve== | ||
| + | * Protocol | ||
| + | *# Beginning with the lowest concentration solution first, place 5 mL in a clean, dry small glass test tube. | ||
| + | *# Add 100 μL of 5 M KNO<sub>3</sub> as an ionic strength adjustor. | ||
| + | *# Stir the solution well, then place the electrode in the solution and measure the mV. | ||
| + | *# Repeat the measurement twice more. | ||
| + | *# Remove the electrode, rinse it well with deionized water, and blot it dry with Kimwipes. | ||
| + | *# Repeat steps 1-5 for all solutions | ||
| + | |||
| + | * Notes | ||
| + | ** The calibration solutions were at the following concentrations of Ag<sup>+</sup>: 0.0001 M, 0.0010 M, and 0.0105 M. The electrode was stored in 0.0105 M AgNO<sup>3</sup> until next needed. | ||
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### --> | <!-- ##### DO NOT edit below this line unless you know what you are doing. ##### --> | ||
| - | + | ||
__NOTOC__ | __NOTOC__ | ||
Revision as of 15:48, 12 February 2013
Customize your entry pages
| |
Objectives
100Ag-LMT
Ag+ Calibration Curve
|
|