User:Matthew R Skorski/Notebook/471 - Exp BioChem/2015/11/17: Difference between revisions
From OpenWetWare
(Autocreate 2015/11/17 Entry for User:Matthew_R_Skorski/Notebook/471_-_Exp_BioChem) |
(fix raw html notebook nav) |
||
(One intermediate revision by one other user not shown) | |||
Line 2: | Line 2: | ||
|- | |- | ||
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span> | |style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span> | ||
|style="background-color: #F2F2F2" align="center"| | |style="background-color: #F2F2F2" align="center"|[[File:Report.png|frameless|link={{#sub:{{FULLPAGENAME}}|0|-11}}]][[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|[[File:Resultset_previous.png|frameless|link={{#lnpreventry:{{FULLPAGENAME}}}}]][[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]] }}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]][[File:Resultset_next.png|frameless|link={{#lnnextentry:{{FULLPAGENAME}}}}]]}} | ||
|- | |- | ||
| colspan="2"| | | colspan="2"| | ||
<!-- ##### DO NOT edit above this line unless you know what you are doing. ##### --> | <!-- ##### DO NOT edit above this line unless you know what you are doing. ##### --> | ||
== | ==Objective== | ||
To go over the data collected so far and look for inconsistencies. For the 1 μM fluorescence sample the 30 minute and 120 minute samples both had very high values for their blanks, which could explain why those values went negative. Also, 60 minutes was off as it was much lower than expected. For 100 nM it doesn't look like any samples would need to be rerun as the samples make a rough linear trend. It would be advised to extend out the time beyond 2 hours. For 10 nM 135 minutes would need to be rerun as it is much higher than expected. For 1 nM all the samples should be rerun as most of points are negative. | |||
Latest revision as of 01:21, 27 September 2017
Project name | Main project page Previous entry Next entry |
ObjectiveTo go over the data collected so far and look for inconsistencies. For the 1 μM fluorescence sample the 30 minute and 120 minute samples both had very high values for their blanks, which could explain why those values went negative. Also, 60 minutes was off as it was much lower than expected. For 100 nM it doesn't look like any samples would need to be rerun as the samples make a rough linear trend. It would be advised to extend out the time beyond 2 hours. For 10 nM 135 minutes would need to be rerun as it is much higher than expected. For 1 nM all the samples should be rerun as most of points are negative.
|