User:Matt Hartings/Notebook/AU Biomaterials Design Lab/2016/09/29: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
Line 15: Line 15:
# Lysozyme, pH 5, 80C
# Lysozyme, pH 5, 80C


==Description==
==BSA AuNP Fluorescence==
# Add experimental record here. Include what, how, and why...
<u>3 mL Sample</u>
# 0.25 mM AuCl3
## Stock concentration 4.27 mM
## Volume Added: 176 μL
# 3.125 μM BSA
## Stock Concentration 52.6 μM
## Volume Added: 178 μL
# pH 6
## Stock Concentration 1 mM HCl
## Volume Added: 3 μL
# Volume water added: 2643 μL
 
<u>UV-Vis of sample</u>
 
[[Image:20160929 mrh BSA AuNP UVVis.png]]
 
<u>Fluorescence scans</u>
 
# Acquisition information
## Excitation: 290 nm, 10 nm slit width
## Emission: 310-540 nm, 10 nm slit width
## 100 nm/minute
## 61 measurements, 180 second delay between measurements
 
[[Image:20190929 mrh BSAAuNP IntegratedI.png]]
 
[[Image:20190929 mrh BSAAuNP EmissionMax.png]]
 
[[Image:20190929 mrh BSAAuNP scans1.png]]
 
[[Image:20190929 mrh BSAAuNP scans2.png]]
 
[[Image:20190929 mrh BSAAuNP scans3.png]]
 
 
==Lysozyme Fluorescence==
<u>3 mL Sample</u>
# 0.5 μM Lysozyme
## Stock Concentration 210 μM
## Volume Added: 7.1 μL
# pH 5
## Stock Concentration 1 mM HCl
## Volume Added: 30 μL
# Volume Water Added: 2963 μL
 
<u>UV-Vis of sample</u>
 
[[Image:20160929 mrh Lysozyme pH5 UVVis.png]]
 
<u>Fluorescence scans</u>
 
# Acquisition information
## Excitation: 290 nm, 10 nm slit width
## Emission: 310-540 nm, 10 nm slit width
## 100 nm/minute
## 61 measurements, 180 second delay between measurements
 
[[Image:20160929 mrh LysozymepH5 IntegratedI.png]]
 
[[Image:20160929 mrh LysozymepH5 EmissionMax.png]]
 
[[Image:20160929 mrh LysozymepH5 SelectedScans.png]]


==Data==
==Data==

Revision as of 18:58, 29 September 2016

Biomaterials Design Lab <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>



Objective

Run fluorescence scans for

  1. BSA, AuNP, pH 6, 80C
  2. Lysozyme, pH 5, 80C

BSA AuNP Fluorescence

3 mL Sample

  1. 0.25 mM AuCl3
    1. Stock concentration 4.27 mM
    2. Volume Added: 176 μL
  2. 3.125 μM BSA
    1. Stock Concentration 52.6 μM
    2. Volume Added: 178 μL
  3. pH 6
    1. Stock Concentration 1 mM HCl
    2. Volume Added: 3 μL
  4. Volume water added: 2643 μL

UV-Vis of sample

Fluorescence scans

  1. Acquisition information
    1. Excitation: 290 nm, 10 nm slit width
    2. Emission: 310-540 nm, 10 nm slit width
    3. 100 nm/minute
    4. 61 measurements, 180 second delay between measurements


Lysozyme Fluorescence

3 mL Sample

  1. 0.5 μM Lysozyme
    1. Stock Concentration 210 μM
    2. Volume Added: 7.1 μL
  2. pH 5
    1. Stock Concentration 1 mM HCl
    2. Volume Added: 30 μL
  3. Volume Water Added: 2963 μL

UV-Vis of sample

Fluorescence scans

  1. Acquisition information
    1. Excitation: 290 nm, 10 nm slit width
    2. Emission: 310-540 nm, 10 nm slit width
    3. 100 nm/minute
    4. 61 measurements, 180 second delay between measurements

Data

  • Add data and results here...

Notes