ObjectiveMeasure lysozyme unfolding at pH 4 and 80 °C with no gold present. This is a complimentary measurement for here and here. Descriptionmeasurement solution
(second sample)
(third sample)
DataThe first two samples were too concentrated and saturated the detector. I meant to take data every 5 minutes by took a sample at 3 minutes by mistake. It is labeled lysozyme_ph4_80C_05. The actual 5 minute sample is labeled as lysozyme_ph4_80C_05b. From then, I keep the 1 sample every 5 min pace. So I have samples for: 0, 3, 5, 10, 15, 20, etc.
NotesThis area is for any observations or conclusions that you would like to note.
|