* An attempt was made to use the UV-Vis equipment for chemiluminescence by blocking the source lamp (D-2). The measuring mode was set on energy setting. The widest slid width available was 5.0 nm.
* An attempt was made to use the UV-Vis equipment for chemiluminescence by blocking the source lamp (D-2). The measuring mode was set on energy setting. The widest slid width available was 5.0 nm.
* Data collection was not possible. No signal was collected.
* Data collection was not possible. No signal was collected.
==Preparation of Lysozyme stock==





Revision as of 10:19, 27 October 2012

Project name <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>

Electrophoresis of the mutated DNA plasmids

  • Transferred 5 μL of the mutated plasmid into a new sterilized tube; leaving out one tube containing 45 μL.
  • Simultaneously, added 1 μL of the gel loading dye 6x blue into the 5 μL plasmid and added 1 μL of DpnI into the 45 μL plasmid.
  • The sample containing the DpnI was placed in a VWR analog heatblock at 37°C.
  • The agarose gel was prepared by dissolving 1.23 g of agarose in 35 mL of TAE buffer. The agarose was heated in a microwave for 35s.
  • When the solution is clear, the agarose was poured into the gel electrophoresis tray with the comb in place.
  • A wait period of 30 min. was allotted for the gel to solidify. Upon observing the gel is already in its solidified state, the comb was gently removed to avoid breakage.
  • The chamber containing the gel tray was filled with TAE buffer to the point where the gel is completely submerged of the buffer.
  • The plasmid with the loading dye were inserted to the wells 3 and 4 using an automatic delivery pipet.
  • The Horton 5B Electrophoresis system (chamber containing the tray) was connected to the BioRad power supply powerpac 200 at 85V.