User:Lymperopoulos Loukas/Notebook/Experimental Chemistry/2016/09/28: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
No edit summary
(fix raw html notebook nav)
 
Line 2: Line 2:
|-
|-
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span>
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span>
|style="background-color: #F2F2F2" align="center"|<html><img src="/images/9/94/Report.png" border="0" /></html> [[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>[[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]]<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>}}
|style="background-color: #F2F2F2" align="center"|[[File:Report.png|frameless|link={{#sub:{{FULLPAGENAME}}|0|-11}}]][[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|[[File:Resultset_previous.png|frameless|link={{#lnpreventry:{{FULLPAGENAME}}}}]][[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]][[File:Resultset_next.png|frameless|link={{#lnnextentry:{{FULLPAGENAME}}}}]]}}
|-
|-
| colspan="2"|
| colspan="2"|

Latest revision as of 02:06, 27 September 2017

Project name Main project page
Previous entry      Next entry

Objectives

The objective for today includes the following:

  1. Test the 20% Bentonite beads and 30% dry Bentonite beads
  2. Collect and analyze UV Vis data for the 10% bentonite and 10% AC beads


Protocol

Testing the new bentonite beads
The 20% Bentonite beads and the 30% powder Bentonite beads were tested using the same procedure that was used on the 10% Bentonite beads.

UV Vis of the 10% Bentonite and 10% Activated Carbon beads
3 mL samples of the MG load and water rinse fractions from the 10% Bentonite and 10% Activated Carbon columns were analyzed using UV VIS. Using the calibration curves made from MG standards, we were able to calculate how much MG was both absorbed and desorbed from the beads. These results are shown below.

Observations

20% Bentonite beads:

  • 17 MG rinses, 3 DI water rinses
  • 13 drops per minute

The test results for the 20% Bentonite beads make sense, as this column should exhibit higher absorption (and thus more MG rinses) than the 10% Bentonite beads column.

30% powder Bentonite beads:

  • 7 MG rinses, 4 DI water rinses
  • 39 drops per minute

The test results for the 30% Bentonite powder beads do not make sense. This column exhibited the lowest adsorption out of all the Bentonite columns, when it should have exhibited the highest. It also had the fastest flow rate. We hypothesized that these test results may be the result of our use of dry Bentonite in the synthesis of the 30% Bentonite beads, as opposed to Bentonite in solution. In order to test our hypothesis, we planned to synthesize and test 30% Bentonite beads made from a Bentonite solution.

Data

Table 1: Adsorption/desorption results of the 10% AC beads


Table 2: Adsorption/desorption results of the 10% Bentonite beads


As shown by the results above, the 10% AC beads were much less effective not only in adsorption, but about 30% of what was absorbed by the AC beads were desorped when pure water was eluted through.