User:Linh N Le/Notebook/2009/06/19

From OpenWetWare
Jump to navigationJump to search
Project name <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>

To Do

  • Autoclave more tips
  • Work on Kinesin if Brigette comes in
  • Organize the wiki

Autoclave

  • Round 1
    • 1 bottle of small centrifuge tubes
    • 1 bottle of large centrifuge tubes
    • 2 boxes 1000μL tips
    • 1 box 100ul tips
    • 1 box 10ul tips
  • Round 2
    • We have no-sterilized tips for the 2.5ul pipetteman
    • 6 boxes of 2.5ul (labeled 10ul) tips
    • They are in the new eppindorf boxes with a black background

Hiring

  • I finally got hired!
  • I just need to head down to HR on Lomas and University to fill out paperwork
  • I'm doing a timesheet right now
    • I believe Koch and I came to an agreement that the month of May was a "work for free" period with a pay increase the rest of the summer to make up for it.
      • As such, i will only "report" time from Jun1-now

Kinesin

  • I polymerized a batch of the RMTs while Brigette made some kinesin
  • She aliquoted ~6 tubes of kinesin (1ul ea), flash froze and stored in the -80c
  • She is making the motillity assay we made last time, with the same casein (the BGB koch made).
  • The first go with the kinesin was a bust
    • It was different this time, as there were alot more tubes stuck to the glass than last time
  • We decided to try a few things at the same time differently
    • first, i made a new BGB using the old powder and even older brb80 that koch made 5 yrs ago
      • We used that to coat the glass
    • Second, Brigette was afraid that there wasnt enough ATP so she tripled the concentration
  • We did 2 samples, one with same kinesin + super atp
  • old kinesin + super atp + more BRBCT
    • The thinking here was that Brigette made a too high on kinesin concentration and so we diluted it some more
  • Suffice it to say, there was not very much change in what the samples looked at from earlier.
  • I did take a video of tubes bleaching and exploding!

What could have went wrong

  • Besides the obvious "we messed it up"
  • The BGB could be bad
    • doubtful because Koch has made assays with BGB before
  • Brigette mentions that Koch's recipe for kinesin was off the top of his head, so maybe koch was wrong? (Koch wrong?! Blasphemous!!!)
  • The kinesin could be terribly slow and not see-a-ble
    • on that note: Brigette used the "leftovers" of the vial, so that could also be an issue