==Description==
'''Microwave Assisted Acid Base Hydrolysis'''
'''Microwave Assisted Acid Base Hydrolysis'''
*40 µL of 1 mg/ml BSA in water with 2 µL of 450 mM DTT
*100µL of AuNP and 50µL of the 6M HCl, swirl around. Use the mixer goes faster until colorless. takes apart the nano particle
*Add 40 µL of 2 M NaOH in a 1.5 ml polypropylene vial
*100µL of 4 M NaOH  
*Capped and placed in microwave 1000 W Power
* take 100µL of aunt naoh and hcl in tubing
*With excess energy being absorbed by 100 ml of water in loosely covered container beside
* add 2µL Dtt
*Microwave sample for 30-30 s and UV-Vis was measured
* cap it and stick it where it will stand up right stick in microwave with flask of water for 2 min
* should be hydrolyzed and take uv spectrum with a reference of NaOH and Hcl
 
 


'''AUNP+BSA+DYE  and  BSA + DYE remake both and uv-vis, as well as fluorescence'''
'''AUNP+BSA+DYE  and  BSA + DYE remake both and uv-vis, as well as fluorescence'''

Revision as of 10:21, 11 April 2012

Biomaterials Design Lab <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>


Objective

- redo two dye attachments - and the microwave reaction

Description

Microwave Assisted Acid Base Hydrolysis

  • 100µL of AuNP and 50µL of the 6M HCl, swirl around. Use the mixer goes faster until colorless. takes apart the nano particle
  • 100µL of 4 M NaOH
  • take 100µL of aunt naoh and hcl in tubing
  • add 2µL Dtt
  • cap it and stick it where it will stand up right stick in microwave with flask of water for 2 min
  • should be hydrolyzed and take uv spectrum with a reference of NaOH and Hcl


AUNP+BSA+DYE and BSA + DYE remake both and uv-vis, as well as fluorescence

Data

  • redid bsa+dye, didn't do bsa+AUNP+dye because we lost the sample and only have enough AUNPs for one reaction will attempt to redo tom followed procedure on march 6 and feb 14
  • no microwave reaction because technique is being tested by another group to make sure it works, no point in attempting if it doesnt work and wasting material

Notes

This area is for any observations or conclusions that you would like to note.


Use categories like tags. Change the "Course" category to the one corresponding to your course. The "Miscellaneous" tag can be used for particular experiments, as instructed by your professor. Please be sure to change or delete this tag as required so that the categories remain well organized.