* Extract Dialyzed 30:1 Colloid Solutions against CaCl<sub>2</sub> that were dialyzed on [http://openwetware.org/wiki/User:Khyra_A._Neal/Notebook/Chem_571/2014/10/21 October 21,2014] | |||
Bradford Analysis of Extracted Colloid Solutions | |||
* 100 μL sample | * 100 μL sample | ||
* 200 μL Bradford Reagent diluted (1:3) | * 200 μL Bradford Reagent diluted (1:3) | ||
Line 18: | Line 17: | ||
* Run UV-Vis between 400 nm and 800 nm | * Run UV-Vis between 400 nm and 800 nm | ||
3. UV-Vis and Fluorescence | |||
There are no peaks at 280 nm for the dialyzed colloid solutions because phenylalanine, tryptophan, and tyrosine are reducing agents to gold. There is no free protein remaining in solution after dialysis. | |||
The diagrams below confirm the above statement. | |||
*Insert Diagram here* | |||
4. Prepare dialysis of 0.6 g/L Lysozyme vs KI | |||
* Use 3500 MWCO tubing | |||
* Add 1 mL 0.6 g/L Lysozyme solution to 5 cells on one side of chamber | |||
* Add 1 mL 2 mM, 5 mM, 10 mM, 25 mM, and 50 mM KI to the opposite side of the chamber (one concentration per cell) | |||
* Secure wells by screwing them to prevent any evaporation | |||
* Place on low speed shaker for one week | |||
** Our lysozyme stock solution precipitated out so we are using 0.6 g/ L Lysozyme that was prepared by Monika today. O | |||
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### --> | |||
|} | |} | ||
__NOTOC__ | __NOTOC__ |
Revision as of 11:54, 22 October 2014
Project name | <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page <html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html> </html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html> |
Ocotober 22, 2014Tasklist
Bradford Analysis of Extracted Colloid Solutions
3. UV-Vis and Fluorescence There are no peaks at 280 nm for the dialyzed colloid solutions because phenylalanine, tryptophan, and tyrosine are reducing agents to gold. There is no free protein remaining in solution after dialysis. The diagrams below confirm the above statement.
|