| ==Purpose==
| |
| * ADA protein were transferred from dialysis tubing into 15mL falcon tubes
| |
| * Make Au/ADA samples with the following mole ratios: 60 - 70 - 80 - 90 - 100 - 110 - 120 - 130 - 140 - 150, with ADA fraction 2 after dialysis.
| |
| * Un-dialyzed Au/ADA samples and Au/HRP made on [[User:Keyun Wang/Notebook/Experimental Biological Chemistry I/2012/11/14|2012/11/14]] were run on UV-vis spectrometer and Atomic Absorption Spectrometer in order to compare spectra results for Au/ADA, Au/HRP, Au/Lysozyme, and Au/BSA.
| |
| * Resuspend Au/HRP samples in different concentration and pH of Tris buffer to test ionic strength.
| |
|
| |
| ==Procedure for Dialysis==
| |
| * Dialysis beaker containing dialysis tubing enclosed with ADA protein fractions were taken from the 4°C cold room into room temperature lab room.
| |
| * The dialysis clips were taken off from dialysis tubing. ADA protein fractions were poured into a sterile 15mL falcon tubes.
| |
| * This process was repeated for all three protein fractions: ADA fraction 1&3 made on [[User:Keyun Wang/Notebook/Experimental Biological Chemistry I/2012/11/06|2012/11/06]], ADA fraction 2 made on [[User:Keyun Wang/Notebook/Experimental Biological Chemistry I/2012/11/06|2012/11/06]], and ADA fraction purified on [[User:Keyun Wang/Notebook/Experimental Biological Chemistry I/2012/10/03|2012/10/03]].
| |
| * ADA fractions in 15mL falcon tubes were stored in 4°C refrigerator.
| |
|
| |
| ==Procedure for making dialyzed Au/ADA samples==
| |
| * Au/ADA samples were made with the following mole ratios:
| |
| 60 - 70 - 80 - 90 - 100 - 110 - 120 - 130 - 140 - 150
| |
| * Stock solution of HAuCl<sub>4</sub> was made on [[User:Keyun Wang/Notebook/Experimental Biological Chemistry I/2012/09/05|2012/09/05]] with a concentration of 10.5uM.
| |
| * Stock solution for ADA was the ADA protein fraction made in [[User:Keyun Wang/Notebook/Experimental Biological Chemistry I/2012/10/03|2012/10/03]] after dialysis. The ADA stock solution has a concentration of 58.36μM.
| |
| * Volume of ADA protein was set at 137.1uL and a range of HAuCl<sub>4</sub> was used from 45.71μL to 114.3μL. Water was added to the sample to increase the volume of sample to 8mL. Volumes of each reactants are shown in table below:
| |
| {| {{table}}
| |
| | align="center" style="background:#f0f0f0;"|'''Au/ADA ratio'''
| |
| | align="center" style="background:#f0f0f0;"|'''ADA added[uL]'''
| |
| | align="center" style="background:#f0f0f0;"|'''HAuCl4 Added [uL]'''
| |
| | align="center" style="background:#f0f0f0;"|'''Water Added[uL]'''
| |
| | align="center" style="background:#f0f0f0;"|'''[ADA]final[uM]'''
| |
| | align="center" style="background:#f0f0f0;"|'''[HAuCl4]final[uM]'''
| |
| |-
| |
| | 60||137.1||45.71||7817.2||1||60
| |
| |-
| |
| | 70||137.1||53.3||7809.6||1||70
| |
| |-
| |
| | 80||137.1||60.9||7802||1||80
| |
| |-
| |
| | 90||137.1||68.6||7794.4||1||90
| |
| |-
| |
| | 100||137.1||76.2||7786.8||1||100
| |
| |-
| |
| | 110||137.1||83.8||7779.1||1||110
| |
| |-
| |
| | 120||137.1||91.4||7771.5||1||120
| |
| |-
| |
| | 130||137.1||99||7763.9||1||130
| |
| |-
| |
| | 140||137.1||106.7||7756.3||1||140
| |
| |-
| |
| | 150||137.1||114.3||7748.7||1||150
| |
| |-
| |
| |
| |
| |}
| |
|
| |
| * The samples were made in 15mL non-sterile falcon tubes. After all reactants were added, samples are capped and wrapped around with aluminum foil.
| |
| * Samples were placed in incubator at 85°C for 4 hours then cooled down to room temperature.
| |
|
| |
| ==Procedure for Running UV-vis Spectrometer on Au/ADA and Au/HRP samples==
| |
| * UV-vis spectrometer were run in spectrum method. A range of 200nm to 800nm were ran on all Au/ADA and Au/HRP samples made on [[User:Keyun Wang/Notebook/Experimental Biological Chemistry I/2012/11/14|2012/11/14]].
| |
| * 3mL of distilled water was placed in quartz cuvette with 1cm pathlength and set as base line solution. 3mL taken from supernatant of Au/ADA and Au/HRP samples were placed in an identical quartz cuvette with 1cm pathlength for spectra measurement.
| |
|
| |
| ==Results for Running UV-vis Spectrometer on Au/ADA and Au/HRP samples==
| |
|
| |
|
| | Nothing was done. |
|
| |
|