User:Karmella Haynes/Notebook/PcTF Genomics/2013/07/04

From OpenWetWare

(Difference between revisions)
Jump to: navigation, search
(Autocreate 2013/07/04 Entry for User:Karmella_Haynes/Notebook/PcTF_Genomics)
(mm/dd/yy)
Line 13: Line 13:
----
----
-
'''Line item 1'''<br>
+
'''Luciferase activity assay - time point: 4 days'''<br>
-
> Samples
+
 
 +
 
 +
<u>Cell prep</u>
 +
* Harvested cells (induced on 6/30/13)
 +
** Seeded new 2 new plates with non-induced cells from 6/30/13
 +
** Pelleted all of the dox+ cells, resuspended in 2 mL FACS buffer
 +
 
 +
 
 +
<u>Assay reagents</u>
 +
* Used the Biotium Steady-Luc Firefly HTS Assay Kit (same as 6/18/13)
 +
 
 +
 
 +
<u>Luc assay</u>
 +
* Filtered '''700 μL cells''' through strainer caps
 +
* Other steps same as 6/18/13
 +
 
 +
 
 +
<u>Cell counts</u>
 +
* Wang lab's Accuri flow cytometer.
 +
* Set machine to read 20 uL of cells
 +
* Be sure to "clean" with water-run in between samples
 +
 
{| class="wikitable" border="0" cellspacing="3" <!-- Rxn. table -->
{| class="wikitable" border="0" cellspacing="3" <!-- Rxn. table -->
|-valign="top"
|-valign="top"
-
| <u>Reagent</u> || <u>Volume</u>  
+
| <u>Sample ID</u> || <u>Gated count/ 20 μL</u> || &nbsp; || <u>Cells/ 100 μL</u>
|-
|-
-
| reagent 1 || # μL
+
| sample 1 || 10,880 || x5 = || 54,400
|-
|-
-
| reagent 2 || #
+
| sample 2 || 10,430 || x5 = || 52,150
|-
|-
-
| reagent 3 || #
+
| sample 3 || 11,897 || x5 = || 59,485
|-
|-
-
| reagent 4 || #
+
| sample 4 || 10,316 || x5 = || 51,580
|-
|-
-
| dH<sub>2</sub>O || #
+
| sample 5 || 9,784 || x5 = || 48,920
|-
|-
-
| &nbsp; || # μL
+
| sample 6 || 11,549 || x5 = || 57,745
|}
|}
-
 
-
--> Reaction conditions
 

Revision as of 22:41, 4 July 2013

Pc-TF Genomics Main project page
Previous entry      Next entry


mm/dd/yy

  • Line item 1

Luciferase activity assay - time point: 4 days


Cell prep

  • Harvested cells (induced on 6/30/13)
    • Seeded new 2 new plates with non-induced cells from 6/30/13
    • Pelleted all of the dox+ cells, resuspended in 2 mL FACS buffer


Assay reagents

  • Used the Biotium Steady-Luc Firefly HTS Assay Kit (same as 6/18/13)


Luc assay

  • Filtered 700 μL cells through strainer caps
  • Other steps same as 6/18/13


Cell counts

  • Wang lab's Accuri flow cytometer.
  • Set machine to read 20 uL of cells
  • Be sure to "clean" with water-run in between samples


Sample ID Gated count/ 20 μL   Cells/ 100 μL
sample 1 10,880 x5 = 54,400
sample 2 10,430 x5 = 52,150
sample 3 11,897 x5 = 59,485
sample 4 10,316 x5 = 51,580
sample 5 9,784 x5 = 48,920
sample 6 11,549 x5 = 57,745



Personal tools