* Flow cytometry of PcTF+ U2OS cells
----
----
-
'''Line item 1'''<br>
+
'''Flow cytometry at Biodesign'''<br>
-
> Samples
+
 
 +
Samples:
 +
# 2.0 μg plasmid/ 1x10<sup>6</sup> cells
 +
# 1.0 μg
 +
# 0.5 μg
 +
# 0.2 μg
 +
# 0.1 μg
 +
# blank (no transfection)
 +
 
 +
Harvesting:
 +
* Detached cells w/ 0.5 mL trypsin medium
 +
* Pelleted in ab-free medium
 +
* Washed once with 1xPBS buffer. Resuspended in 0.5 mL 1xPBS
 +
 
 +
Flow cytometry:
 +
* Took cells over the BDI on ice. Strained cells once through cell strainer caps (purchased 10 from  Tong Xu); forced cells through cap with pipette (did not centrifuge)
 +
* Ran samples 6 (blank), 1, 2, and 3 and recorded SS, FS, and mCherry
 +
* Very modest mCh over background (blank). Tong noted that the mCherry laser was not optimal for this fluorophore.
 +
 
 +
----
 +
'''Flow cytometry - Wang Lab's Accuri C6'''<br>
 +
* Diluted samples 3x to get reads per sec. down to 240
 +
* Signal over background looked pretty good for mCherry
 +
* Drawback is that voltage/ sensitivity cannot be adjusted, so blank signal is in the 10<sup>3</sup> range.
 +
* Do further tests to see if Accuri GFP settings can detect CFP (AmCyan).
 +
 
 +
 
{| class="wikitable" border="0" cellspacing="3" <!-- Rxn. table -->
{| class="wikitable" border="0" cellspacing="3" <!-- Rxn. table -->

Revision as of 18:47, 11 June 2013

Pc-TF Genomics Main project page
Previous entry      Next entry


06/03/13

  • Flow cytometry of PcTF+ U2OS cells

Flow cytometry at Biodesign

Samples:

  1. 2.0 μg plasmid/ 1x106 cells
  2. 1.0 μg
  3. 0.5 μg
  4. 0.2 μg
  5. 0.1 μg
  6. blank (no transfection)

Harvesting:

  • Detached cells w/ 0.5 mL trypsin medium
  • Pelleted in ab-free medium
  • Washed once with 1xPBS buffer. Resuspended in 0.5 mL 1xPBS

Flow cytometry:

  • Took cells over the BDI on ice. Strained cells once through cell strainer caps (purchased 10 from Tong Xu); forced cells through cap with pipette (did not centrifuge)
  • Ran samples 6 (blank), 1, 2, and 3 and recorded SS, FS, and mCherry
  • Very modest mCh over background (blank). Tong noted that the mCherry laser was not optimal for this fluorophore.

Flow cytometry - Wang Lab's Accuri C6

  • Diluted samples 3x to get reads per sec. down to 240
  • Signal over background looked pretty good for mCherry
  • Drawback is that voltage/ sensitivity cannot be adjusted, so blank signal is in the 103 range.
  • Do further tests to see if Accuri GFP settings can detect CFP (AmCyan).