* Continue fluorescence detection through pressure testing analysis of hydrogel samples (new modifications & better results)
* Continue fluorescence detection through pressure testing analysis of hydrogel samples (new modifications & better results)


==Hydrogel Pressure Samples Tested 3==
==Straight Pippette: Hydrogel Pressure Samples Tested 3==
'''RECALL HYDROGEL PRESSURE TESTING PROTOCOL ON 2/20/13 & FLUORESCENCE ANALYSIS PROCEDURES ON 2/13/13'''  
'''RECALL HYDROGEL PRESSURE TESTING PROTOCOL ON 2/20/13 & FLUORESCENCE ANALYSIS PROCEDURES ON 2/13/13'''  


Line 17: Line 17:
| align="center" style="background:#f0f0f0;"|'''PVOH Type'''
| align="center" style="background:#f0f0f0;"|'''PVOH Type'''
| align="center" style="background:#f0f0f0;"|'''Clay Selection'''
| align="center" style="background:#f0f0f0;"|'''Clay Selection'''
| align="center" style="background:#f0f0f0;"|'''Amount of Hydrogel Used (Straight Pipette)(g)'''
| align="center" style="background:#f0f0f0;"|'''Amount of Hydrogel Used (g)'''
|-
|-
| 1||50:50||130K||110% CEC NaMT w/ DMHXLBR||0.1006
| 1||50:50||130K||110% CEC NaMT w/ DMHXLBR||0.1006

Revision as of 16:15, 14 April 2013

PVOH Research <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>

OBJECTIVES

  • Continue fluorescence detection through pressure testing analysis of hydrogel samples (new modifications & better results)

Straight Pippette: Hydrogel Pressure Samples Tested 3

RECALL HYDROGEL PRESSURE TESTING PROTOCOL ON 2/20/13 & FLUORESCENCE ANALYSIS PROCEDURES ON 2/13/13

Sample Order PVOH vs. Clay Ratio PVOH Type Clay Selection Amount of Hydrogel Used (g)
1 50:50 130K 110% CEC NaMT w/ DMHXLBR 0.1006
2 50:50 130K 110% CEC NaMT w/ DMHXLBR 0.1022
3 90:10 130K Laponite 0.1031
4 50:50 146K 110% CEC Laponite w/ DMHXLBR 0.1066
5 90:10 130K 110% CEC Laponite w/ DMHXLBR 0.1083
6 90:10 130K 110% CEC NaMT w/ DMHXLBR 0.1003
7 50:50 130K 110% CEC Laponite w/ DMHXLBR 0.1036
8 50:50 146K Laponite 0.1016
9 90:10 130K 110% CEC NaMT w/ DMHXLBR 0.1011
10 90:10 146K 110% CEC NaMT w/ DMHXLBR 0.1020
11 50:50 130K NaMT 0.1024
12 50:50 130K 50% CEC NaMT w/ Bu3HdP+ 0.1015
13 50:50 146K 110% CEC NaMT w/ DMHXLBR 0.0998
14 90:10 130K 50% CEC NaMT w/ Bu3HdP+ 0.1026

Notes

  • The pipettes that provided the best fluorescence results for each sample were both the straight plastic and 90° angle bent pipettes.
  • All samples run maintained a composition incorporating Rhodamine 6G dye
  • All samples on 3/01/13 were tested using the straight pipette. (See figure listed below)