User:Karlena L. Brown/Notebook/PVOH Research/2013/02/27
From OpenWetWare
(Difference between revisions)
(→PVOH Film Preparations) |
(→Hydrogel Pressure Samples Tested) |
||
| Line 8: | Line 8: | ||
==OBJECTIVES== | ==OBJECTIVES== | ||
==Hydrogel Pressure Samples Tested== | ==Hydrogel Pressure Samples Tested== | ||
| + | '''RECALL HYDROGEL PRESSURE TESTING PROTOCOL ON 2/20/13 & FLUORESCENCE ANALYSIS PROCEDURES ON 2/13/13''' | ||
| + | |||
| + | {| {{table}} | ||
| + | | align="center" style="background:#f0f0f0;"|'''Sample Order''' | ||
| + | | align="center" style="background:#f0f0f0;"|'''PVOH vs. Clay Ratio''' | ||
| + | | align="center" style="background:#f0f0f0;"|'''PVOH Type''' | ||
| + | | align="center" style="background:#f0f0f0;"|'''Clay Selection''' | ||
| + | | align="center" style="background:#f0f0f0;"|'''Amount of Hydrogel Used (g)''' | ||
| + | |- | ||
| + | | 1||90:10||146K||110% CEC NaMT w/ DMHXLBR||0.1084 | ||
| + | |- | ||
| + | | 2||90:10||130K||NaMT||0.1044 | ||
| + | |- | ||
| + | | 3||50:50||146K||110% CEC NaMT w/ DMHXLBR||0.1092 | ||
| + | |- | ||
| + | | 4||90:10||130K||110% CEC Laponite w/ DMHXLBR||0.1050 | ||
| + | |- | ||
| + | | 5||50:50||130K||NaMT||0.1050 | ||
| + | |- | ||
| + | | 6||90:10||130K||Laponite||0.1015 | ||
| + | |- | ||
| + | | 7||50:50||146K||110% CEC Laponite w/ DMHXLBR||0.1080 | ||
| + | |- | ||
| + | | 8||50:50||130K||Laponite||0.1036 | ||
| + | |- | ||
| + | | 9||90:10||130K||110% CEC NaMT w/ DMHXLBR||0.1011 | ||
| + | |- | ||
| + | | 10||50:50||130K||110% CEC Laponite w/ DMHXLBR||0.1036 | ||
| + | |- | ||
| + | | 11||90:10||130K||110% CEC NaMT w/ DMHXLBR||0.1011 | ||
| + | |- | ||
| + | | 12||90:10||146K||Laponite||0.1026 | ||
| + | |- | ||
| + | | 13||50:50||130K||50% CEC NaMT w/ Bu<sub>3</sub>HdP<sup>+</sup>||0.1052 | ||
| + | |- | ||
| + | | 14||50:50||146K||Laponite||0.1045 | ||
| + | |- | ||
| + | | 15||90:10||130K||50% CEC NaMT w/ Bu<sub>3</sub>HdP<sup>+</sup>||0.1145 | ||
| + | |} | ||
| + | |||
==Notes== | ==Notes== | ||
* The pipettes that provided the best fluorescence results for each sample were both the straight plastic pipette and 90° angle bent pipette. | * The pipettes that provided the best fluorescence results for each sample were both the straight plastic pipette and 90° angle bent pipette. | ||
Revision as of 23:55, 4 March 2013
Main project page Previous entry Next entry
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
OBJECTIVESHydrogel Pressure Samples TestedRECALL HYDROGEL PRESSURE TESTING PROTOCOL ON 2/20/13 & FLUORESCENCE ANALYSIS PROCEDURES ON 2/13/13
Notes
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||




