==PVOH Film Preparations==
+
==OBJECTIVES==
-
'''Prepared PVOH films in water:'''
+
==Hydrogel Pressure Samples Tested==
-
* In 10mL beaker, weigh out ~ 0.5 grams PVOH (MW 130,000)
+
==Notes==
-
'''(Actual Mass = 0.4934g)'''
+
* The pipettes that provided the best fluorescence results for each sample were both the straight plastic pipette and 90° angle bent pipette.
-
* Then, using a graduated cylinder add ~ 3 mL H<sub>2</sub>O to the beaker
+
* All samples run maintained a composition incorporating Rhodamine 6G dye
-
* In another 10mL beaker, weigh out ~ 1.0 gram PVOH (MW 130,000)
+
* All samples on 2/27/13 were tested using the bent pipette containing the 90° angle. (See figure listed below)
-
'''(Actual Mass = 0.9965g)'''
+
Figure 1. Image of bent pipette used for pressure testing
-
* Then, using a graduated cylinder add ~ 5 mL H<sub>2</sub>O to the beaker
+
[[Image:Bent pipette 2 27 13.jpg]]
-
 
+
<br>
-
'''Standard PVOH Film Protocol:'''
+
-
* After adding and combining PVOH (MW 130,000) in small beakers with H<sub>2</sub>O, add stir bars and prepare to stir solution.
+
-
* On hot plate, stir and heat both beaker solutions at 70-80°C for ~ 12 min or until PVOH dissolves.
+
-
* Once PVOH solids thoroughly dissolve in solution, pour each solution in a Teflon dish to sit, cool, and dry in a fume hood for ~ 1 day.
+
-
 
+
-
'''Notes:'''
+
-
* An additional 2-3 mL H<sub>2</sub>O was added to each solution to aid the dissolving of the PVOH
+
-
* Heat was reduced when solutions began to boil too rapidly
+
-
* While transferring solutions to Teflon dishes, loss of sample within the small beakers (sample loss = incomplete sample transfer)
+
-
 
+
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->

Revision as of 22:22, 4 March 2013

PVOH Research Main project page
Previous entry      Next entry

OBJECTIVES

Hydrogel Pressure Samples Tested

Notes

  • The pipettes that provided the best fluorescence results for each sample were both the straight plastic pipette and 90° angle bent pipette.
  • All samples run maintained a composition incorporating Rhodamine 6G dye
  • All samples on 2/27/13 were tested using the bent pipette containing the 90° angle. (See figure listed below)

Figure 1. Image of bent pipette used for pressure testing Image:Bent pipette 2 27 13.jpg