User:Karlena L. Brown/Notebook/PVOH Research/2012/10/31

From OpenWetWare

(Difference between revisions)
Jump to: navigation, search
(PVOH Film Preparations)
(ISE Film Analysis)
Line 9: Line 9:
==Films Examined using FTIR==
==Films Examined using FTIR==
==Ion Selective Electrode Film Procedures==
==Ion Selective Electrode Film Procedures==
-
==ISE Film Analysis==
+
==ISE Film Analysis: Varied Ion Solution==
 +
'''A crosslinked PVOH 22K film containing 1mL glutaldehyde that had been exchanged for 10 min in the CuSO<sub>4</sub> solution was used for an Ion Selective Electrode Analysis.'''
 +
 
 +
{| {{table}}
 +
| align="center" style="background:#f0f0f0;"|'''Time Recordings'''
 +
| align="center" style="background:#f0f0f0;"|'''Initial Volume(mL)'''
 +
| align="center" style="background:#f0f0f0;"|'''Final Volume (mL)'''
 +
| align="center" style="background:#f0f0f0;"|'''Conductivity (μS/cm)'''
 +
|-
 +
| 8:50A||30||30||864
 +
|-
 +
| 9:00A||30||30||869
 +
|-
 +
| 9:30A||30||30||874
 +
|-
 +
| 10:00A||30||30||865
 +
|-
 +
| 10:30A||30||30||863
 +
|-
 +
| 11:00A||30||29.5||861
 +
|-
 +
| 11:30A||29.5||30||858
 +
|-
 +
| 12:00P||30||30||853
 +
|-
 +
| 3:15P||30||29.8||840
 +
|-
 +
| 9:00P||29.8||28||819
 +
|}
 +
 
==Notes==
==Notes==

Revision as of 04:25, 24 November 2012

PVOH Research Main project page
Previous entry      Next entry

OBJECTIVES

Films Examined using FTIR

Ion Selective Electrode Film Procedures

ISE Film Analysis: Varied Ion Solution

A crosslinked PVOH 22K film containing 1mL glutaldehyde that had been exchanged for 10 min in the CuSO4 solution was used for an Ion Selective Electrode Analysis.

Time Recordings Initial Volume(mL) Final Volume (mL) Conductivity (μS/cm)
8:50A3030864
9:00A3030869
9:30A3030874
10:00A3030865
10:30A3030863
11:00A3029.5861
11:30A29.530858
12:00P3030853
3:15P3029.8840
9:00P29.828819

Notes