|style="background-color: #F2F2F2" align="center"| | |style="background-color: #F2F2F2" align="center"|[[File:Report.png|frameless|link={{#sub:{{FULLPAGENAME}}|0|-11}}]][[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|[[File:Resultset_previous.png|frameless|link={{#lnpreventry:{{FULLPAGENAME}}}}]][[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]] }}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]][[File:Resultset_next.png|frameless|link={{#lnnextentry:{{FULLPAGENAME}}}}]]}} | ||
|- | |- | ||
| colspan="2"| | | colspan="2"| | ||
Line 11: | Line 11: | ||
==Objective== | ==Objective== | ||
# Standardization of NH<sub>4</sub>SCN | |||
# Storage Lysozyme-KI dialysis from October 15 | |||
# Begin Colloid-KI dialysis | |||
==Description== | ==Description== | ||
# Add | # Standardization of NH<sub>4</sub>SCN - to be used in analysis of dialysis solutions with KI | ||
## Add 3 mL 1 M HNO<sub>3</sub> and 2 mL AgNO<sub>3</sub> to 10 mL DI H<sub>2</sub>O | |||
## Add 200 μL Ferric alum indicator | |||
## Titrate with your NH<sub>4</sub>SCN solution | |||
## The solution turned orange at 16.3mL of titrant | |||
# storage of lysozyme-KI dialysis | |||
## the solutions were removed from the dialysis wells and placed in 1.5mL centrifuge tubes for further analysis | |||
##* Note of caution: previous dialysis using lysozyme have been ineffective as the lysozyme has begun to crash out. This dialysis may need to be repeated. | |||
# Colloid-KI dialysis | |||
## After washing the dialysis chambers, a 3500 MWCO dialysis tube was wet with HPLC water and placed in the block | |||
## colloid solutions previously produced were placed on one side of the tubing | |||
##* Colloid solutions were prepared on ... | |||
## 50mM, 5mM, 500μM, 50μM, and 5μM solutions were placed on the other side of the membrane | |||
##* these solutions were produced on ... | |||
==Data== | ==Data== | ||
* | * 0.38130g NH<sub>4</sub>SCN in 500mL of H<sub>2</sub>O | ||
* 1.27481g AgNO<sub>3</sub> in 100mL of H<sub>2</sub>O | |||
==Notes== | ==Notes== | ||
It is recommended that measurements involving analysis of protein content should be carried out immediately following dialysis in order to ensure the protein does not precipitate out while awaiting analysis. | |||