User:Hannah Harvey/Notebook/CHEM-471 Fall 2016/2016/10/04: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
No edit summary
(fix raw html notebook nav)
 
Line 2: Line 2:
|-
|-
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span>
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span>
|style="background-color: #F2F2F2" align="center"|<html><img src="/images/9/94/Report.png" border="0" /></html> [[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>[[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]]<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>}}
|style="background-color: #F2F2F2" align="center"|[[File:Report.png|frameless|link={{#sub:{{FULLPAGENAME}}|0|-11}}]][[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|[[File:Resultset_previous.png|frameless|link={{#lnpreventry:{{FULLPAGENAME}}}}]][[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]][[File:Resultset_next.png|frameless|link={{#lnnextentry:{{FULLPAGENAME}}}}]]}}
|-
|-
| colspan="2"|
| colspan="2"|

Latest revision as of 02:04, 27 September 2017

Project name Main project page
Previous entry      Next entry

Objectives

  1. Run fluorescence data for lysozyme at pH=7
  2. Create stock solutions for use on 10.05.2016

Description

Fluorescence

  1. Solutions made using measurements below
  2. Fluorescence data run every 3 minutes for 3 hours

Solutions for 10/05/2016
Solutions were added to glass test tubes, covered with foil, and placed in an oven set to 80°C for 4 hours.

Data


Figure 1 Maximum emission data in a solution of pH 7.


Figure 2 Integrated fluorescence data in a solution of pH 7.


Figure 3 Full emission spectra for important time points: t=0, 15, 33, 105, 180 min.

Figure 3 Explanation

  1. At t=0 min, we see a max emission far to the left of the other emission spectra.
  2. At t=15 min, this maximum has shifted up and to the right.
  3. Until t=33 min, the maximum for each spectra decreases until the shown maximum.
  4. After t=33 min, the maximum begins increasing again.
  5. At t=105 min, the maximum continues to increase, but the "shoulder" seen at around 475 nm begins going away.
  6. t=180 shows the final full spectra obtained.

UV-vis solutions for 09.14.2016

Table 1 UV-vis solutions made for [Fructose]=.0mM with silver


Table 2 UV-vis solutions made for [Fructose]=.0625mM with silver