User:Dominique Brager/Notebook/481 Notebook/2016/10/28: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
(fix raw html notebook nav)
 
(2 intermediate revisions by one other user not shown)
Line 2: Line 2:
|-
|-
|style="background-color: #EEE"|[[Image:BDLlogo_notext_lr.png|128px]]<span style="font-size:22px;"> Biomaterials Design Lab</span>
|style="background-color: #EEE"|[[Image:BDLlogo_notext_lr.png|128px]]<span style="font-size:22px;"> Biomaterials Design Lab</span>
|style="background-color: #F2F2F2" align="center"|<html><img src="/images/9/94/Report.png" border="0" /></html> [[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>[[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]]<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>}}
|style="background-color: #F2F2F2" align="center"|[[File:Report.png|frameless|link={{#sub:{{FULLPAGENAME}}|0|-11}}]][[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|[[File:Resultset_previous.png|frameless|link={{#lnpreventry:{{FULLPAGENAME}}}}]][[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]][[File:Resultset_next.png|frameless|link={{#lnnextentry:{{FULLPAGENAME}}}}]]}}
|-
|-
| colspan="2"|
| colspan="2"|
Line 30: Line 30:


==Data==
==Data==
* Swelling Data


*30% beads with MG Data
*30% beads with MG Data

Latest revision as of 02:08, 27 September 2017

Biomaterials Design Lab Main project page
Previous entry      Next entry



Objective

  • Continued Running Malachite Green through 50% column
  • Started running heavy metals through Activated Carbon
  • Did Data Analysis for ICP on 10% beads
  • Ran UV-Vis
  • Did swelling for 10% beads

Description

  • MG with 50% beads
  • Used VWR MiniPump Variable Flow at 90 rpm
  • Activated Carbon Beads
  • Allowed to flow freely (no pump)
  • Mass of Column wet: 16.38975 g
  • Mass with beads: 17.8669 g
  • 40% column
  • Mass Dry (not top, no clamp):10.373g

Data

  • 30% beads with MG Data



Mass of MG Eluted: 3.75 mg

MG not adsorbed: 0.1878 mg

MG Adsorbed: 3.5622 mg

MG Desorbed: 36384 mg

Mass of Beads: 0.706 g

Capacity of beads: 5.0456 mg/g

Mass of Clay in Beads: 0.2118 g

Capacity of Clay: 16.181 mg/g