User:Dhea Patel/Notebook/Hemoglobin Project/2013/02/13

From OpenWetWare

(Difference between revisions)
Jump to: navigation, search
m (Description)
m (Description)
Line 10: Line 10:
==Description==
==Description==
 +
 +
*10.5mg mannitol in Tris buffer, solvent: Acetonitrile
 +
*10.8mg p-sorbitol in phosphate buffer, solvent: Acetonitrile
 +
*10.5mg mannitol in tris buffer, solvent: ethyl acetate
 +
*12.1mg p-sorbitol in phosphate buffer, solvent: ethyl acetate
 +
*11.7mg mannitol in tris buffer, solvent: water
 +
*10.0mg p-sorbitol in phosphate buffer, solvent: water
 +
*11.6mg mannitol in  tris buffer, solvent: chloroform
 +
*10.0mg p-sorbitol in phosphate buffer, solvent: chloroform
*Each solvent was used as a blank.
*Each solvent was used as a blank.

Revision as of 09:56, 15 February 2013

Project name Main project page
Previous entry      Next entry

Objective

  • Run UV-vis and Fluorescence on p-sorbitol in phosphate buffer and mannitol in tris buffer samples in either MeOH, acetone, acetonitrile, ethyl acetate, water, or chloroform.

Description

  • 10.5mg mannitol in Tris buffer, solvent: Acetonitrile
  • 10.8mg p-sorbitol in phosphate buffer, solvent: Acetonitrile
  • 10.5mg mannitol in tris buffer, solvent: ethyl acetate
  • 12.1mg p-sorbitol in phosphate buffer, solvent: ethyl acetate
  • 11.7mg mannitol in tris buffer, solvent: water
  • 10.0mg p-sorbitol in phosphate buffer, solvent: water
  • 11.6mg mannitol in tris buffer, solvent: chloroform
  • 10.0mg p-sorbitol in phosphate buffer, solvent: chloroform
  • Each solvent was used as a blank.
  • The data was corrected for the blank and a corrected baseline.
  • UV-vis scanned from 200-800nm




Personal tools