User:Dhea Patel/Notebook/Experimental Biological Chemistry Notebook/2012/09/05: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
Line 21: Line 21:
#After it was confirmed that a reaction was indeed taking place, the mixtures were made with concentrations of 60μM, 80μM, 100μM, 120μM, 128μM, 130μM, 132μM, 133μM, 134μM, 136μM, 138μM, 140μM, 160μM, and 170μM, taking into account the new masses and new actual concentrations of the stock solutions.  
#After it was confirmed that a reaction was indeed taking place, the mixtures were made with concentrations of 60μM, 80μM, 100μM, 120μM, 128μM, 130μM, 132μM, 133μM, 134μM, 136μM, 138μM, 140μM, 160μM, and 170μM, taking into account the new masses and new actual concentrations of the stock solutions.  


*[[User:Melissa_Novy/Notebook/CHEM-571/2012/09/05| Re-suspending Fibers]]
*Re-suspending Fibers
*'''[[User:Abigail E. Miller|Abigail E. Miller]] 11:02, 17 September 2012 (EDT)''':what was done? explain briefly but clearly what can be found on that page.
**Please refer to [[User:Melissa_Novy/Notebook/CHEM-571/2012/09/05| Melissa's entry]] for details on centrifuging the Au/BSA solutions and adding the Tris buffer.
***2 different pHs of Tris buffer were tested: pH 8 and 10.
***The concentrations of each pH of Tris buffer was observed using 1 mM, 100 μM, and 10 μM Tris buffer on fibers with arbitrary AU/BSA molar ratios.
 
*[[User:Dhea_Patel/Notebook/Experimental_Biological_Chemistry_Notebook/2012/09/04| UV-vis]]
*[[User:Dhea_Patel/Notebook/Experimental_Biological_Chemistry_Notebook/2012/09/04| UV-vis]]
Adjustments:
**UV-Vis was run on 1mL of the resuspended fibers, with the wavelength range of 700-200nm, looking for a peak around 550nm.
#1mL of the resuspended fibers were examined.
**The data was plotted on an Absorbance vs. Wavelength graph.
*'''[[User:Abigail E. Miller|Abigail E. Miller]] 11:02, 17 September 2012 (EDT)''':what was done on the UV-Vis?


==Data==
==Data==

Revision as of 11:16, 25 September 2012

AU Biomaterials Design Lab <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>

Objectives

  • to re-make the Au/BSA solutions, because the mixtures from yesterday did not react,
  • to re-suspend the fibers in varying concentrations of Tris Buffer with pHs 10 and 8, and
  • to run UV-vis on the resuspended fibers.

Description

Adjustments:

  1. The spatula was wrapped in parafilm to measure out both the BSA and the HAuCl4.
  2. Only one concentration was made initially as a test. It was placed in the oven at 85°C for an hour to make sure a reaction was taking place. This TEST sample was removed after an hour. Dark Blue/Purple fibers formed. This TEST sample was saved for later testing.
  3. After it was confirmed that a reaction was indeed taking place, the mixtures were made with concentrations of 60μM, 80μM, 100μM, 120μM, 128μM, 130μM, 132μM, 133μM, 134μM, 136μM, 138μM, 140μM, 160μM, and 170μM, taking into account the new masses and new actual concentrations of the stock solutions.
  • Re-suspending Fibers
    • Please refer to Melissa's entry for details on centrifuging the Au/BSA solutions and adding the Tris buffer.
      • 2 different pHs of Tris buffer were tested: pH 8 and 10.
      • The concentrations of each pH of Tris buffer was observed using 1 mM, 100 μM, and 10 μM Tris buffer on fibers with arbitrary AU/BSA molar ratios.
  • UV-vis
    • UV-Vis was run on 1mL of the resuspended fibers, with the wavelength range of 700-200nm, looking for a peak around 550nm.
    • The data was plotted on an Absorbance vs. Wavelength graph.

Data

  • Table of Measurements for Au/BSA mixtures
Stock Solution Concentrations ' ' ' '
Theoretical Actual [uM]
BSA HAuCl4 BSA HAuCl4
15 uM 10 mM 15.355 10501
Vol [μL] '
BSA HAuCl4
4000 4000
μM Ratio [Au/BSA] ' Volume ' '
BSA HAuCl4 BSA [μL] HAuCl4 [μL] H2O [mL]
1 60 260.5014653 157.515 3.581983535
1 80 260.5014653 210.02 3.529478535
1 100 260.5014653 262.525 3.476973535
1 120 260.5014653 315.03 3.424468535
1 128 260.5014653 336.032 3.403466535
1 130 260.5014653 341.2825 3.398216035
1 132 260.5014653 346.533 3.392965535
1 133 260.5014653 349.15825 3.390340285
1 134 260.5014653 351.7835 3.387715035
1 136 260.5014653 357.034 3.382464535
1 138 260.5014653 362.2845 3.377214035
1 140 260.5014653 367.535 3.371963535
1 160 260.5014653 420.04 3.319458535
1 170 260.5014653 446.2925 3.293206035
4623.06525 Total μL
  • UV-Vis of Resuspended Fibers via Tris Buffer
  • Abigail E. Miller 11:02, 17 September 2012 (EDT):is there suppose to be data here?

Notes

  • The stocks were made with the incorrect concentrations, so the reaction did not occur properly.

Image of solutions made September 5th

  • All the solutions from the batch made on September 5th and a close-up of the solutions from the batch made on September 5th. The solution was made with the parafilmed spatula. THe solution spent 4 hours in a 85°C oven.