==Tasks==
* Insert content here...
* Prepare 500 mL stock solution of 50 mM NaCl
 
*1 L stock buffer solution of 50 mM glycine
*Prepare a 25 mL solution of 1 g/L lysozyme
*set up 5 lysozyme dyalisis experiments:
* 4.0 mL of the prepared lysozyme solution beaker filled with a 50 mM NaCl stock solution. Using a 3500 g/mol MWCO tubing
* 4.0 mL of the prepared lysozyme solution in beaker filled with a 50 mM glycine stock solution. Using a 3500 g/mol MWCO tubing
* 4.0 mL of the prepared lysozyme solution in beaker filled with 50 mM glycine stock solution. Using a 25k g/mol MWCO tubing
* 4.0 mL of the 35.6:1 [Au]:[lys] solution in beaker filled with 50 mM glycine stock solution. Using a 3500 g/mol MWCO tubing
* 4.0 mL of the prepared lysozyme solution  in a beaker filled with H2O. Using a 3500 g/mol MWCO tubing
*4.0 mL of the prepared lysozyme solution in a 50 mM glycine solution. Using a 15k g/mol MWCO tubing


<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->

Revision as of 19:41, 17 September 2014

Project name <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>

Tasks

  • Prepare 500 mL stock solution of 50 mM NaCl
  • 1 L stock buffer solution of 50 mM glycine
  • Prepare a 25 mL solution of 1 g/L lysozyme
  • set up 5 lysozyme dyalisis experiments:
  • 4.0 mL of the prepared lysozyme solution beaker filled with a 50 mM NaCl stock solution. Using a 3500 g/mol MWCO tubing
  • 4.0 mL of the prepared lysozyme solution in beaker filled with a 50 mM glycine stock solution. Using a 3500 g/mol MWCO tubing
  • 4.0 mL of the prepared lysozyme solution in beaker filled with 50 mM glycine stock solution. Using a 25k g/mol MWCO tubing
  • 4.0 mL of the 35.6:1 [Au]:[lys] solution in beaker filled with 50 mM glycine stock solution. Using a 3500 g/mol MWCO tubing
  • 4.0 mL of the prepared lysozyme solution in a beaker filled with H2O. Using a 3500 g/mol MWCO tubing
  • 4.0 mL of the prepared lysozyme solution in a 50 mM glycine solution. Using a 15k g/mol MWCO tubing