User:Andy Maloney/Surface passivation effects on kinesin and microtubules: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
 
(29 intermediate revisions by the same user not shown)
Line 1: Line 1:
[[Category:AM_OpenNotebookScienceDissertation]]
[[Category:AM_OpenNotebookScienceDissertation]]
==Purpose==
==Purpose==
This page describes the experiment where I investigated gliding speed variations of microtubules using different surface passivation schemes using the [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page gliding motility assay].
This page describes the experiment where I investigated gliding speed variations of microtubules using different surface passivation schemes using the [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page gliding motility assay].


Line 10: Line 9:
* [[User_talk:Andy_Maloney|Click here to post general comments about the open dissertation]].
* [[User_talk:Andy_Maloney|Click here to post general comments about the open dissertation]].
* [[User_talk:Andy_Maloney/Surface_passivation_effects_on_kinesin_and_microtubules|Click here to post comments to this chapter's talk page]].
* [[User_talk:Andy_Maloney/Surface_passivation_effects_on_kinesin_and_microtubules|Click here to post comments to this chapter's talk page]].
A pdf version of the Introduction can be [http://www.openwetware.org/wiki/Image:AMDissertation_Chapter_3.pdf downloaded here]. This is the final snapshot of the dissertation that has been approved by my committee. This file will inevitably become out of sync with the wiki pages.
A zip folder containing the LaTeX code can be down loaded [http://www.openwetware.org/images/c/ce/Chapter_3_-_Surface_passivation.zip here].
'''Note'''
This chapter ended up becoming an Open Access paper on PLoS ONE. You can view it on their website, comment if you like and you can cite it below,
Maloney A, Herskowitz LJ, & Koch SJ (2011) [http://www.plosone.org/article/info%3Adoi%2F10.1371%2Fjournal.pone.0019522 Effects of Surface Passivation on Gliding Motility Assays]. PLoS ONE, 6(6): e19522. doi: [http://dx.doi.org/10.1371/journal.pone.0019522 10.1371/journal.pone.0019522].
<br style="clear:both;"/>
==Acknowledgements==
I would like to thank Dr. Haiqing Liu (while in the lab of [http://cint.lanl.gov/gabriel_montano.shtml Dr. Gabriel A. Montano]) for supplying kinesin to our lab. I would also like to thank [http://panda.unm.edu/pandaweb/people/person.phtml?personID=76 Dr. Susan Atlas] and the support from DTRA CB Basic Research Program under Grant No. HDTRA1-09-1-008 and the UNM IGERT on Integrating Nanotechnology with Cell Biology and Neuroscience NSF Grant DGE-0549500. Finally, I'd like to thank [http://www.biotec.tu-dresden.de/research/schaeffer/ Dr. Erik Schaeffer] for his discussions on temperature stabilization.
<br style="clear:both;"/>


==Introduction==
==Introduction==
Line 19: Line 33:
|width="100"|'''Figure 1:''' Image of our mascot "Kiney" at the microscope where I perform experiments. The plush doll form of Kiney was made by [http://www.childsown.com/ Child's Own Studios].
|width="100"|'''Figure 1:''' Image of our mascot "Kiney" at the microscope where I perform experiments. The plush doll form of Kiney was made by [http://www.childsown.com/ Child's Own Studios].
|}
|}
Both kinesin and microtubules are vital components of eukaryotic cells. Kinesin is used as a vehicle to shuttle items from one part of the cell to another and microtubules are the roads that kinesin travel on. Kinesin walks along microtubules in one direction and does so by converting chemical energy, in the form of ATP hydrolysis, to linear motion (Carter 2005, Vale 1997, Hua 1997, Vale 1985, Goldstein 1999). Observations of this system are typically carried out in two manners: the gliding motility assay or with an optical trap (Block 1990, Yildez 2004, Gelles 1988). The gliding motility assay (Böhm 1997, Böhm 2000, Böhm Stracke & Unger 2000) is the experimental procedure of interest for this study and a description on how to prepare a gliding motility assay can be found in [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page Chapter 1].
Both kinesin and microtubules are vital components of eukaryotic cells. Kinesin is used as a vehicle to shuttle items from one part of the cell to another and microtubules are the roads that kinesin travel on. Kinesin walks along microtubules in one direction and does so by converting chemical energy, in the form of ATP hydrolysis, to linear motion (Carter 2005, Vale 1997, Hua 1997, Vale 1985, Goldstein 1999). Biophysical observations of motility can be carried out in many different ways, however, the two most prominent observational techniques investigate kinesin and microtubules via the gliding motility assay or, with an optical trap (Block 1990, Yildiz 2004, Gelles 1988). The gliding motility assay (Bohm 1997, Bohm 2000a, Bohm 2000b) is the experimental procedure of interest for this study and a description on how to prepare a gliding motility assay can be found in [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page Chapter 2].


These studies show that the type of casein used in an assay affects the kinesin and microtubule system. One way to measure this affect is to observe the speed at which microtubules glide. This study aims to show that there are subtle differences in the speeds at which microtubules will glide at and I will offer some of my own ideas as to why I think these differences exist.
This study aims to show that there are subtle differences in the speeds at which microtubules will glide at depending on the surface passivation used. It also shows that different surface passivations support different lengths of microtubules. This chapter will discuss the subtle differences to the gliding motility assay already outlined in [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page Chapter 2]. I will also discuss some of the technological hurdles that were accomplished in order to obtain stable speed data.
<html>
<br style="clear:both;"/>
<br />
<br />
<br />
<br />
<br />
<br />
</html>


==Methods and materials==
==Methods and materials==
In this section, I will discuss the technological hurdles required to obtain stable data and the subtle differences in the generic gliding motility assay described in [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page Chapter 1].
In this section, I will discuss the technological hurdles required to obtain stable data and the subtle differences in the generic gliding motility assay described in [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page Chapter 2].
 
<br style="clear:both;"/>
===Temperature stabilization===
===Temperature stabilization===
{| border="0" align="right" valign="bottom" cellpadding=10px   
{| border="0" align="right" valign="bottom" cellpadding=10px   
Line 41: Line 48:
| align="left" valign="top" width="300" | '''Figure 2:''' Graph showing three experiments using different passivation schemes. Note that each individual trace continuously increases in speed over time.
| align="left" valign="top" width="300" | '''Figure 2:''' Graph showing three experiments using different passivation schemes. Note that each individual trace continuously increases in speed over time.
|}
|}
Temperature stabilization is crucial for observing stable speeds. Without it, I observed microtubule gliding speeds increase over time. Figure 2 shows data that did not use a temperature stabilized objective and shows a sharp initial increase in speed which, over time would taper but never level off. There are three different assays in the graph, one each of: alpha casein, beta casein and whole casein. A description of the different types of caseins will be given below, briefly they are the constituents of whole casein described in [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page Chapter 1]. I initially thought that I observed the goal of this study; which was to observe speed changes dependent on the type of passivation used. However, what I observed was that kinesin is a very sensitive temperature probe.
Temperature stabilization is crucial for observing stable speeds. Without it, I observed microtubule gliding speeds increase over time. Figure 2 shows data that did not use a temperature stabilized objective. The data show a sharp initial increase in speed which, over time would taper but never level off. There are three different assays in the graph, one each of: alpha casein, beta casein and whole casein. A description of the different types of caseins will be given below, briefly they are the constituents of whole casein described in [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page Chapter 2]. Using the data from Figure 2, I thought that I observed the goal of this study; which was to observe speed changes dependent on the type of passivation used. However, what I observed was that kinesin is a very sensitive temperature probe as I will discuss in more detail below.
 
I presented Figure 2 at the Biophysical Society Meeting 2010 where Stefan Diez suggested that the increase in speed over time was due to a temperature effect. I did not initially understand his comment because there was nothing attached to the microscope that could be heating the sample. So, I didn't really do anything about it. I presented more of the same data showing speed changes due to water isotopes and osmolytes at a conference in Santa Fe later that year (Maloney 2010). Erik Schaeffer attended the conference and he again told me that there was a temperature issue and that was why I saw the speed increase over time. He described to me the microscope setup used in his lab which stabilized the temperature of the objective with millikelvin precision. He told me that with this setup, he could tell rather precisely when and if a graduate student in his lab turned on the computer monitor near the microscope. This story blew me away and I of course didn't think it possible but, it most certainly is true as I found out with my experiments. If a computer monitor not even attached to the microscope could register a temperature increase on the objective, then there was a highly probable possibility that my microscope was heating up due to the mercury lamp.


I presented Figure 2 at the Biophysical Society Meeting 2010 where Stefan Diez suggested that the increase in speed over time was due to a temperature effect. I did not initially understand his comment because there was nothing attached to the microscope that could be heating the sample. So, I didn't really do anything about it. I presented more of the same data showing speed changes due to water isotopes and osmolytes at a conference in Santa Fe later that year (Maloney 2010). Dr. Erik Schaeffer of TU Dresden attended the conference and he again told me that there was a temperature issue with my data. He described to me the microscope setup used in his lab which stabilized the temperature of their objective with millikelvin precision. He told me that with this setup, he could tell rather precisely when and if a graduate student in his lab turned on the computer monitor near the microscope. This story blew me away and I of course didn't think it possible but, it most certainly is true as I found out with my experiments. If a computer monitor not even attached to the microscope could register a temperature increase on the objective, then there was a possibility that my microscope was heating up due to the mercury lamp.
{| border="0" align="center" valign="bottom" cellpadding=10px   
{| border="0" align="center" valign="bottom" cellpadding=10px   
|-
|-
| align="left" | [[Image:AM ObjTempNoStab.jpg|300px]]
| align="left" | [[Image:AM ObjTempNoStab.jpg|300px]]
| align="left" | [[Image:AM_RealTime.png|300px]]
| align="left" | [[Image:AM TempwithSpikes.jpg|300px]]
|-
|-
| align="left" valign="top" width="300" | '''Figure 3:''' Temperature of the microscope objective with no temperature stabilization and the mercury lamp on shining through the objective. The black curve is when the lamp was on and the red was when it was switched off.
| align="left" valign="top" width="300" | '''Figure 3:''' Temperature of the microscope objective with no temperature stabilization and the mercury lamp on shining through the objective. The black curve is when the lamp was on and the red was when it was switched off.
| align="left" valign="top" width="300" | '''Figure 4:''' Graph showing the three experiments from Figure 3 plotted with respect to the time of day they were performed at.
| align="left" valign="top" width="300" | '''Figure 4:''' Temperature of the microscope objective with temperature stabilization. The initial spikes are due to turning the stabilization electronics on and off. The smaller spikes at later times are when a slide is removed from the objective and replaced with a new slide at room temperature.
|}
|}
 
The temperature of the entire microscope does increase over time due to having the mercury lamp on. Figure 3 shows the temperature of the objective due to having the mercury lamp on and shining through it. The temperature of the objective was taken at its top, near where the sample would be. No oil was used on the objective for this measurment. As can be clearly seen, the objective does reach a stable temperature, albeit 5.5 hours after turning the lamp on. This is not ideal for experiments as one would have to wait 5.5 hours before being able to take measurements. This graph does not show the effect of placing a microscope slide at room temperature on the objective as doing so causes the objective temperature to decrease, as can be seen in Figure 4.
The temperature of the entire microscope does increase over time due to having the mercury lamp on. Figure 3 shows the temperature increase of the objective due to having the mercury lamp on and shining through it. The temperature of the objective was taken at the top, near where the sample would be and no oil was used on the objective. As can be clearly seen, the objective does reach a stable temperature, albeit 5.5 hours after turning the lamp on. This is not ideal for experiments as one would have to wait 5.5 hours before being able to take measurements. This graph does not show the effect of placing a microscope slide on the objective either. Adding a slide at room temperature will cause the temperature of the objective to decrease as can be seen in Figure 5.
{| border="0" align="center" valign="bottom" cellpadding=10px
 
Returning to the data taken in Figure 2, I decided to re-plot the data against absolute time, i.e. from the seconds measured since 1904. Thankfully I took all the data in Figure 2 on the same day and when plotted with their time stamps appropriately zeroed from the first image taken, Figure 4, one can clearly see that there is an overall increase in speed as time goes on. As a bonus, one can also see that over the time the slide is on the objective, the speeds increase. This was due to the fact that the slides were at room temperature and they heated up when on the objective. A plot showing the effect of temperature on the objective for turning the heating element on and off, and adding oil and removing and replacing a slide on the objective can be seen in Figure 5.
{| border="0" align="right" valign="bottom" cellpadding=10px
|-
|-
| align="left" | <html><object width="300" height="300"><param name="movie" value="http://www.youtube.com/v/vq3z-TaDcuI?fs=1&amp;hl=en_US"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="http://www.youtube.com/v/vq3z-TaDcuI?fs=1&amp;hl=en_US" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="300" height="300"></embed></object></html>
| align="left" | [[Image:AM_RealTime.png|300px]]
| align="left" | [[Image:AM ACwithTempStabilization.jpg|300px]]
|-
|-
| align="left" valign="top" width="300" | '''Movie 1:''' Showing the focus drift due to temperature instabilities. When the overall image becomes brighter, the focus is drifting.
| align="left" valign="top" width="300" | '''Figure 5:''' Graph showing speed values of data from Figure 2 after plotting against the absolute time they were observed.
| align="left" valign="top" width="300" | '''Figure 6:''' Graph showing speed values after temperature stabilization.
|}
|}
This finding I felt was unfortunate because it basically said that the large differences in gliding speeds was solely due to temperature effects and not on the chemistry of passivation. Nonetheless, I took this opportunity to build a similar system to what Erik Schaeffer used in his lab to stabilize the temperature of the microscope objective (Mahamdeh 2009). As can be seen in Figure 5, with a stable temperature, speed measurements can be recorded with as little as ±4 nm/s errors. This is a feat all to itself since average speeds in the literature can quote errors as large as 50 - 100 nm/s (Böhm 1997). Figure 6 also shows the large increase in speed observed in my earlier experiments for early times, except now, the data levels off. Figure 6 shows quite nicely that without temperature stabilization, speed measurements would not be stable. As an added bonus, Movie 1 shows that when there was no temperature stabilization on the objective, the focus would change periodically. This required constant adjustments to the focus of the objective. The movie looses focus when the overall image gets brighter. This is due to the objective collecting more light from the fluorescent microtubules in solution and not at the surface of the slide where the kinesin is adhered to.
Re-plotting the data taken in Figure 2 against absolute time, i.e. from the seconds measured since 1904, shows a different story about microtubule speed measurements and casein passivation than is shown. Thankfully I took all the data in Figure 2 on the same day and when plotted with their time stamps appropriately zeroed from the first image taken, Figure 5, one can clearly see that there is an overall increase in speed as time goes on. One can also see that over the time the slide is on the objective, the microtubule speeds increase. This was due to the fact that the slides were at room temperature and they heated up when on the objective. A plot showing the effect of temperature on the objective for turning the heating element on and off, and adding oil and removing and replacing a slide on the objective can be seen in Figure 4.


A detailed description of the build can be found in an [http://www.instructables.com/id/Objective-heater/ Instructables] post. This design can maintain a temperature to ±0.1°C. There are very few studies that indicate whether or not observation of the gliding motility assay was done with temperature stabilization or not. It has been shown that temperature does play a crucial role in obtaining stable data (Böhm 2000, Böhm Stracke & Unger 2000) in a few studies, as well as, the ones I have done.
This finding I felt was unfortunate because it basically said that the large differences in gliding speeds was solely due to temperature effects and not due to the chemistry of passivation. Nonetheless, I took this opportunity to build a similar system to what Dr. Schaeffer uses in his lab to stabilize the temperature of my microscope objective (Mahamdeh 2009). As can be seen in Figure 4, with a stable temperature, speed measurements can be recorded with as little as ±4 nm/s errors. This is a feat all to itself since average speeds in the literature can quote errors as large as 50 --- 100 nm/s (Bohm 1997). Figure 4 also shows the large increase in speed observed in my earlier experiments for early times, except now, the data levels off. Figure 4 shows quite nicely that without temperature stabilization, speed measurements would not be stable. Figure 7 shows a movie when there was no temperature stabilization on the objective. The movie shows how the focus would drift which required constant adjustments. The movie loses focus when the overall image gets brighter. This is due to the objective collecting more light from the fluorescent microtubules in solution and not at the surface of the slide where the kinesin is adhered to.
{| border="0" align="center" valign="bottom" cellpadding=10px
{| border="0" align="right" valign="bottom" cellpadding=10px
|-
|-
| align="left" | [[Image:AM TempwithSpikes.jpg|300px]]
| align="left" | <html><object width="300" height="300"><param name="movie" value="http://www.youtube.com/v/vq3z-TaDcuI?fs=1&amp;hl=en_US"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="http://www.youtube.com/v/vq3z-TaDcuI?fs=1&amp;hl=en_US" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="300" height="300"></embed></object></html>
| align="left" | [[Image:AM ACwithTempStabilization.jpg|300px]]
|-
|-
| align="left" valign="top" width="300" | '''Figure 5:''' Temperature of the microscope objective with temperature stabilization. The initial spikes are due to turning the stabilization electronics on and off. The smaller spikes at later times are when a slide is removed from the objective and replaced with a new slide at room temperature.
| align="left" valign="top" width="300" | '''Figure 7:''' [http://www.youtube.com/watch?v=vq3z-TaDcuI Click here to view the movie via YouTube]. Movie showing the focus drift due to temperature instabilities. When the overall image becomes brighter, the focus is drifting.
| align="left" valign="top" width="300" | '''Figure 6:''' Graph showing speed values after temperature stabilization.
|}
|}
 
A detailed description of the objective heater build can be found in a post done on the website [http://www.instructables.com/id/Objective-heater/ Instructables]. Briefly, the objective heater is a PID control circuit using a software interface from TeTech. The control circuitry is connected to two 15 kΩ thermistors. One thermistor controls the heating element and the other is used to measure the objective temperature which is recorded by the software. The heating element used was a Kapton flexible heating element. This design can maintain a temperature to ±0.1°C. There are very few studies that indicate whether or not observation of the gliding motility assay was done with temperature stabilization. It has been shown that temperature does play a crucial role in obtaining stable data (Bohm 2000a, Bohm 2000b) in a few studies, as well as, the ones I have done.
<br style="clear:both;"/>
===Materials===
===Materials===
I like to think of the preparation for all the solutions used in an assay as my ''mise en place''. And, just like no one would ever touch a fellow cook's mise en place in a restaurant, no one but me was allowed to use my solutions. These rules were set in place partly due to how finicky these assays are and how I've learned that keeping a tight control on my solutions allows me to quickly replace chemicals when an assay has gone awry.
I like to think of the preparation for all the solutions used in an assay as my [http://en.wikipedia.org/wiki/Mise_en_place ''mise en place'']. And, just like no one would ever touch a fellow cook's mise en place in a restaurant, no one but me was allowed to use my solutions. These rules were set in place partly due to how finicky these assays are and how I've learned that keeping a tight control on my solutions allows me to quickly replace chemicals when an assay has gone awry.


I have already spoken about several of the necessary tools used for this assay in [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page Chapter 1]. Below, I will link to the tools that do not change for this assay and go into greater detail about those that do. Those items in the list that do not have have links will be described below.
I have already spoken about several of the necessary tools used for this assay in [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page Chapter 2]. Below, I will link to the tools that do not change and go into greater detail about those that do. The items in the list that do not have links, will be described below.
* [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#The_PEM_buffer PEM buffer]
* [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#The_PEM_buffer PEM buffer]
* [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#Antifade Antifade] & [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#PEM-Glu PEM-Glu]
* [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#Antifade Antifade] & [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#PEM-Glu PEM-Glu]
* [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#Tubulin Tubulin] for [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#Microtubule_polymerization Microtubule polymerization] & [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#Taxol Taxol] for microtubule stabilization.
* [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#Tubulin Tubulin] for [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#Microtubule_polymerization Microtubule polymerization] & [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_26_Microtubule_Page#Taxol Taxol] for microtubule stabilization.
* [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#Kinesin Kinesin] & [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#PEM-A PEM-A].
* [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#Kinesin Kinesin] & [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#PEM-A PEM-A]
* [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#Flow_cell Flow cells].
* [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#Flow_cell Flow cells]
* Surface passivation chemicals.
* Surface passivation chemicals
<br style="clear:both;"/>
====Passivation solutions====
This experiment used the different bovine casein constituents to investigate speed variations of microtubules in the gliding motility assay. In the temperature stabilization section of this chapter, my initial experiments saw huge differences in speeds using different caseins. As was already mentioned above, the large speed variations were due to temperature effects and not due to the passivation chemicals. Once I stabilized the temperature of my objective, I continued to investigate if there were any variations in speed due to surface passivation. It turns out that there was a difference in speed measurements due to surface passivation, albeit a more subtle difference than what I saw initially without temperature stabilization. To begin this experiment, I purchased the following caseins all from bovine milk.
* A combination of the α<sub>s1</sub>- and α<sub>s2</sub>-caseins purified to 70% [http://www.sigmaaldrich.com/catalog/ProductDetail.do?lang=en&N4=C6780|SIGMA&N5=SEARCH_CONCAT_PNO|BRAND_KEY&F=SPECi (Sigma C6780)]
* β-casein purified to 98% [http://www.sigmaaldrich.com/catalog/ProductDetail.do?lang=en&N4=C6905|SIGMA&N5=SEARCH_CONCAT_PNO|BRAND_KEY&F=SPEC (Sigma C6905)]
* κ-casein purified to 70% [http://www.sigmaaldrich.com/catalog/ProductDetail.do?lang=en&N4=C0406|SIGMA&N5=SEARCH_CONCAT_PNO|BRAND_KEY&F=SPEC (Sigma C0406)]
* Whole casein [http://www.sigmaaldrich.com/catalog/Lookup.do?N5=All&N3=mode+matchpartialmax&N4=c7078&D7=0&D10=c7078&N1=S_ID&ST=RS&N25=0&F=PR (Sigma C7078)]


====Passivation solutions====
This experiment used the different bovine casein constituents to investigate speed variations of microtubules in the gliding motility assay. In the temperature stabilization section of this chapter, my initial experiments saw huge differences in speed with the different caseins used. As was already mentioned above, the large speed variations were due to temperature effects and not due to the passivation chemicals. Once I stabilized the temperature of my objective, I continued to investigate if there were any variations in speed due to surface passivation. It turns out that there was a difference in speed measurements due to surface passivation, albeit a more subtle difference than what I saw initially without temperature stabilization.
{| border="0" align="right" valign="bottom" cellpadding=10px 
|-
| align="left" | [[Image:AM CaseinSolutionWithCondenser.jpg|300px]]
|-
| align="left" valign="top" width="300" | '''Figure 7:''' Condenser unit attached to a solution of whole casein being mixed and heated in PEM.
|}
To begin this experiment, I purchased the following caseins all from bovine milk.
* α<sub>s1</sub>- and α<sub>s2</sub>-caseins purified to 70% [http://www.sigmaaldrich.com/catalog/ProductDetail.do?lang=en&N4=C6780|SIGMA&N5=SEARCH_CONCAT_PNO|BRAND_KEY&F=SPECi Sigma C6780]
* β-casein purified to 98% [http://www.sigmaaldrich.com/catalog/ProductDetail.do?lang=en&N4=C6905|SIGMA&N5=SEARCH_CONCAT_PNO|BRAND_KEY&F=SPEC Sigma C6905]
* κ-casein purified to 70% [http://www.sigmaaldrich.com/catalog/ProductDetail.do?lang=en&N4=C0406|SIGMA&N5=SEARCH_CONCAT_PNO|BRAND_KEY&F=SPEC Sigma C0406]
* Whole casein [http://www.sigmaaldrich.com/catalog/Lookup.do?N5=All&N3=mode+matchpartialmax&N4=c7078&D7=0&D10=c7078&N1=S_ID&ST=RS&N25=0&F=PR Sigma C7078]
Each casein component was reconstituted in PEM under constant stirring. I will outline below the different solutions that were prepared for this experiment giving the naming convention for each solution in the subheading.
Each casein component was reconstituted in PEM under constant stirring. I will outline below the different solutions that were prepared for this experiment giving the naming convention for each solution in the subheading.
 
<br style="clear:both;"/>
=====W-PEM=====
=====W-PEM=====
For a detailed description of how to make W-PEM, please see [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#W-PEM_recipe Chapter 1].
For a detailed description of how to make W-PEM, please see [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page Chapter 2].
 
<br style="clear:both;"/>
=====α-PEM=====
=====α-PEM=====
The subscript "s" attached to alpha casein means "sensitive" since the alpha caseins are the first caseins to be removed from solution by adding over 4 mM calcium. α<sub>s1</sub>-casein comprises approximately 37% of whole bovine casein while α<sub>s2</sub>-casein comprises only 10% (Fox 1998 Ch. 4).
The subscript ''s'' attached to the alpha casein means ''sensitive'' since the alpha caseins are the first caseins to be removed from solution by adding over 4 mM calcium. α<sub>s1</sub>-casein comprises approximately 37% of whole bovine casein while α<sub>s2</sub>-casein comprises only 10% (Fox 1998a). A mixture of the α<sub>s1</sub>- and α<sub>s2</sub>-caseins was purchased from Sigma.


Alpha PEM has 1.0 mg/mL α-casein in PEM. Dissolving α-casein in PEM required approximately 60-80 minutes of constant stirring at room temperature. The procedure I followed to make α-PEM is as follows.
Alpha PEM has 1.0 mg/mL α-casein in PEM. Dissolving α-casein in PEM required approximately 60-80 minutes of constant stirring at room temperature. The procedure I followed to make α-PEM is as follows.
Line 113: Line 111:
# Allow the foam to settle if any.
# Allow the foam to settle if any.
# Aliquot into convenient screw top vials.
# Aliquot into convenient screw top vials.
α-PEM will last for 6 months stored at 4°C. No additional filtering was done on the α-PEM solution.
α-PEM will last for 6 months stored at 4°C. No additional filtering was done on the α-PEM solution.
 
<br style="clear:both;"/>
=====β-PEM=====
=====β-PEM=====
β-casein comprises approximately 35% of the protein in whole bovine casein. It takes approximately 400 mM calcium to remove it from a solution of skim milk (Fox 1998 Ch. 4).
β-casein comprises approximately 35% of the protein in whole bovine casein. It takes approximately 400 mM calcium to remove it from a solution of skim milk (Fox 1998a).


β-PEM has 1.0 mg/mL β-casein in PEM. The procedure for making β-PEM is very similar to how I made α-PEM except for the length of time required to mix.
β-PEM has 1.0 mg/mL β-casein in PEM. The procedure for making β-PEM is very similar to how I made α-PEM except for the length of time required to mix.
Line 125: Line 122:
# Allow the foam to settle if any.
# Allow the foam to settle if any.
# Aliquot into convenient screw top vials.
# Aliquot into convenient screw top vials.
β-PEM will last for 6 months stored at 4°C. No additional filtering was done on the β-PEM solution.
β-PEM will last for 6 months stored at 4°C. No additional filtering was done on the β-PEM solution.
<br style="clear:both;"/>
=====κ-PEM=====
κ-casein is structurally very different from α and β casein. Kappa casein is a glycoprotein and was depicted in Chapter 2's figure of a casein micelle as the ''hairs''. Kappa casein is thought to stabilize the casein micelle and it is unaffected by calcium concentration. It can even help to stabilize alpha and beta caseins from calcium precipitation (Fox 1998a).


=====κ-PEM=====
κ-PEM has 1.0 mg/mL κ-casein in PEM. The procedure for making κ-PEM is very similar to how α-PEM is made, except for the length of time required to mix.
κ-casein is structurally very different from α and β casein. Kappa casein is a glycoprotein and was depicted in [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#Surface_passivation_chemicals Chapter 1's] whole casein micelle's as its "hairs". Kappa casein is thought to stabilize the casein micelle and it is unaffected by calcium concentration. It can even help to stabilize alpha and beta caseins from calcium precipitation (Fox 1998 Ch. 4).
κ-PEM has 1.0 mg/mL κ-casein in PEM. The procedure for making κ-PEM is very similar to how I made κ-PEM except for the length of time required to mix.
# Weigh out 25 mg of κ-casein.
# Weigh out 25 mg of κ-casein.
# Add the 25 mg of κ-casein to 25 mL of PEM.
# Add the 25 mg of κ-casein to 25 mL of PEM.
Line 137: Line 133:
# Allow the foam to settle if any.
# Allow the foam to settle if any.
# Aliquot into convenient screw top vials.
# Aliquot into convenient screw top vials.
κ-PEM will last for 6 months stored at 4°C. No additional filtering was done on the κ-PEM solution.
κ-PEM will last for 6 months stored at 4°C. No additional filtering was done on the κ-PEM solution.
 
<br style="clear:both;"/>
=====M-PEM=====
=====M-PEM=====
A mixed variety of whole casein was also prepared. I called this solution M-PEM. From the stated amounts of the individual casein components, I mixed a "whole" casein type solution using α-PEM, β-PEM, and κ-PEM. I decided to do this because I wanted to see if I could artificially reproduce the results obtained from W-PEM.
From the stated amounts of the individual casein components, I mixed a ''whole'' casein type solution using α-PEM, β-PEM, and κ-PEM which I called M-PEM. I decided to do this because I wanted to see if I could artificially reproduce the results obtained from W-PEM which used the purchased whole bovine casein.


Since all the components of casein were already in solutions of PEM, I just mixed them in a vial to obtain M-PEM.
Since all the components of casein were already in solutions of PEM, I just mixed them in a vial to obtain M-PEM.
* 49% α-casein or 980 μL of α-PEM.
* 49% α-casein or 980 μL of α-PEM.
* 37% β-casein or 740 μL of β-PEM.
* 37% β-casein or 740 μL of β-PEM.
* 14% κ-casein or 280 μL of κ-PEM.
* 14% κ-casein or 280 μL of κ-PEM.
M-PEM will last for 6 months stored at 4°C. No additional filtering was done on the M-PEM solution.
M-PEM will last for 6 months stored at 4°C. No additional filtering was done on the M-PEM solution.


I did not investigate the solubility of the caseins in a solution of PEM. Casein solubility is a complicated function of other casein constituents in solution (Zittle 1961, 1963), temperature (Payensa 1963, O’Connell 2003, Leclerc 1997), genetic variants (Thompson 1969), ionic strength and types of salts in solution (Thompson 1969), calcium ion concentration (Zittle 1961, Zittle 1963, Thompson 1969), and pH (Bingham 1971). Casein solubility measurements were not performed in this study.
I did not investigate the solubility of the caseins in a solution of PEM. Casein solubility is a complicated function of other casein constituents in solution (Zittle 1961, Zittle 1963), temperature (Payens 1963, O'Connell 2003, Leclerc 1997), genetic variants (Thompson 1969), ionic strength and types of salts in solution (Thompson 1969), calcium ion concentration (Zittle 1961, Zittle 1963, Thompson 1969), and pH (Bingham 1971).
<br style="clear:both;"/>


==Experiment and data analysis==
==Experiment and data analysis==
The speed at which microtubules glide at in the motility assay depends on a number of factors one of which, is the pH of the solution. In my PEM solution, the amount of NaOH is approximate since each solution of PEM is pH-ed to 6.89. Böhm (Böhm Stracke & Unger 2000) shows that gliding speed is affected by both the pH and the ionic strength of the solution the motors are in. In an effort to reduce as many variables as possible for speed measurements, I chose to maintain the pH of the PEM buffers at exactly 6.89 and vary the amount of NaOH necessary to achieve this pH.
The speed at which microtubules glide at in the motility assay depends on a number of factors. One of those factors is the pH of the solution. In my PEM solution, the amount of NaOH is approximate since each solution of PEM is pH-ed to 6.89. Bohm (Bohm 2000b) shows that gliding speed is affected by both the pH and the ionic strength of the solution the motors are in. In an effort to reduce as many variables as possible for speed measurements, I chose to maintain the pH of the PEM buffers at exactly 6.89 and vary the amount of NaOH necessary to achieve this pH.


For a complete description of the gliding motility assay, please see [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page Chapter 1]. Briefly, polymerization was carried out in a Thermo PCR Sprint thermocycler held constant at 37˚C and incubated for 30 minutes using 1 µL of the 29% rhodamine-labeled and 71% unlabeled tubulin. After 30 minutes, the microtubules were fixed and diluted by 200x by adding 199 µL of PEM-T. Polymerized microtubules were stored at room temperature and protected from ambient light until used in a motility assay. Storing polymerized microtubules at 4˚C will cause rapid depolymerization (Shelanski 1973).
For a complete description of the gliding motility assay, please see [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page Chapter 2]. Briefly, polymerization was carried out in a Thermo PCR Sprint thermocycler held constant at 37°C and incubated for 30 minutes using 1 μL of the 29% rhodamine-labeled and 71% unlabeled tubulin. After 30 minutes, the microtubules were fixed and diluted by 200x by adding 199 μL of PEM-T. Polymerized microtubules were stored at room temperature and protected from ambient light until used in a motility assay. Storing polymerized microtubules at 4°C will cause rapid depolymerization (Shelanski 1973).
<br style="clear:both;"/>
===Gliding motility assay===
===Gliding motility assay===
Experiments followed the same recipe outlined in [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page Chapter 1]. The steps taken for this experiment were as follows.
Experiments followed the same recipe outlined in [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page Chapter 2]. The steps taken for this experiment were as follows.
# Prepared a [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#Flow_cell flow cell].
# Prepared a [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#Flow_cell flow cell].
# Incubated the flow cell with 1.0 mg/mL of the various caseins in PEM for 10 minutes.
# Incubated the flow cell with 1.0 mg/mL of the various caseins in PEM for 10 minutes.
# During the 10 minute incubation, kinesin was diluted in 0.5 mg/mL of the same casein in PEM used in Step 2, plus 1 mM ATP. The final concentration of kinesin used in these experiments was 27.5 μg/mL.
# During the 10 minute incubation, kinesin was diluted in 0.5 mg/mL of the same casein in PEM used in Step 2, plus 1 mM ATP. The final concentration of kinesin used in these experiments was 27.5 μg/mL.
# After 10 minutes, kinesin was flowed into the flow cell by fluid exchange. This was then allowed to sit for 5 minutes.
# After 10 minutes, kinesin was flowed into the flow cell by fluid exchange. This was then allowed to sit for 5 minutes.
# During the various incubation steps, a new motility solution was prepared for each assay. The different motility assays consisted of:
# During the various incubation steps, a new motility solution was prepared for each assay. The motility assays consisted of:
#* 1 μL of [[User:Andy_Maloney/Kinesin_%26_Microtubule_Page#PEM-A|PEM-A]].
#* 1 μL of [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#PEM-A PEM-A].
#* 1 μL of [[User:Andy_Maloney/Kinesin_%26_Microtubule_Page#The_antifade_system|PEM-Glu]].
#* 1 μL of [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#PEM-Glu PEM-Glu].
#* 2.5 μL of [[User:Andy_Maloney/Kinesin_%26_Microtubule_Page#The_antifade_system|Antifade]].
#* 2.5 μL of [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#Antifade antifade].
#* 0.1 μL of [[User:Andy_Maloney/Kinesin_%26_Microtubule_Page#Tubulin_suspension_in_TSB|Taxol]].
#* 0.1 μL of [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#Taxol Taxol].
#* 90.5 μL of [[User:Andy_Maloney/Kinesin_%26_Microtubule_Page#The_PEM_buffer|PEM]].
#* 90.5 μL of [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#The_PEM_buffer PEM].
#* 5 μL of [[User:Andy_Maloney/Kinesin_%26_Microtubule_Page#Experiments|microtubules]].
#* 5 μL of [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page#Microtubule_polymerization microtubules].
# After the 5 minute incubation with kinesin, the motility solution was introduced to the flow cell by fluid exchange.
# After the 5 minute incubation with kinesin, the motility solution was introduced to the flow cell by fluid exchange.
# The flow cell was then sealed with nail polish.
#The flow cell was then sealed with nail polish.


In order to not dilute the Taxol used to stabilize microtubules, it is added in the motility solution at the same concentration used in PEM-T. This is the same reason why 1 mM ATP is added to the motility solution. I did not want to dilute the amount of ATP the kinesin is stored in. The [http://www.cellbio.duke.edu/kinesin/ kinesin home page] and Verma et. al. (Kinesin, Verma 2008), suggest that adding casein to the motility solution enhances the chances of a gliding motility assay to work properly. I observed that adding casein to the motility solution causes microtubules to undergo non ideal motility, i.e. they move in tight circles and end up wrapping around themselves such that the microtubules look like squiggles and are untrackable. In order to prevent such behavior, I did not include casein in the motility solution.
In order to not dilute the Taxol used to stabilize microtubules, it is added in the motility solution at the same concentration used in PEM-T. Preventing dilution of chemicals is why 1 mM ATP is added to the motility solution as well. The [http://www.cellbio.duke.edu/kinesin/ kinesin home page] and Verma et al. (Kinesin home page, Verma 2008), suggest that adding casein to the motility solution enhances the chances of a gliding motility assay to work properly. I observed that adding casein to the motility solution causes microtubules to undergo non ideal motility, i.e. they move in tight circles and end up wrapping around themselves such that the microtubules look like squiggles and are untrackable. In order to prevent such behavior, I did not include casein in the motility solution.
 
After sealing the flow cell, the slide was immediately placed on the microscope for observation. Data was taken at 5 frames per second with a single exposure time for each frame of 100 ms. The camera software was set to take a total of 600 images for one region of interest (ROI) and have an EMCCD gain of 150. The time to capture 600 frames was approximately 2 minutes of total exposure for one ROI. After the camera had captured 600 frames, I moved the sample on the microscope. I moved the flow cell around because I wanted to get a broad sample of speed measurements from it. One reason for doing this is to try and not continuously sample only one area of kinesin coverage (Hunt 1994). showed that microtubules would slow down against viscous loads if the kinesin concentration was low.  My assays never used small concentrations of kinesin but, to ensure that I had a sampling of speed that did not have to take into account kinesin coverage, I moved the sample around. Each slide was repositioned on the microscope for a total of 15 time giving me 15 ROIs to analyze data from.


After sealing the flow cell, the slide was immediately placed on the microscope for observation. Data was taken at 5 frames per second with a single exposure time for each frame of 100 ms. The camera software (KochLab) was set to take a total of 600 images for one region of interest (ROI) and had an EMCCD gain of 150. The time to capture 600 frames was approximately 2 minutes of total exposure for one ROI. After the camera had captured 600 frames, I moved the sample on the microscope. I did this because I wanted to get a broad sample of speed measurements from the flow cell. Kinesin may not be distributed uniformly on the surface of the flow cel and may give different speed measurements dependent on where the observation took place. Hunt et al. (Hunt 1994) showed that microtubules would slow down against viscous loads if the kinesin concentration was low. My assays never used small concentrations of kinesin but, to ensure that I had a sampling of speed that did not have to take into account kinesin coverage, I moved the sample around. Each slide was repositioned on the microscope for a total of 15 times giving me 15 ROIs to analyze data from.
<br style="clear:both;"/>
===Data analysis===
===Data analysis===
Microtubules were then tracked using a custom LabVIEW tracking application thanks to Larry Herskowitz. The tracking software used image segmentation algorithms to identify microtubule ends via pattern matching. The software did not track microtubules that that had fewer than 100 consecutive images. This lower bound of images was found through experiment to give reliable data. Microtubules that could be tracked with fewer images did not consistently give high fidelity data and thus a lower bound for images was set. The software was unable to track microtubules that had a segmented area less than 55 pixels due to the pattern matching algorithms used. This put a lower bound on the length of trackable microtubules to be around 2 μm. Finally, tracking of microtubules stopped if the microtubule crossed other microtubules or if it came too close to the edges of the ROI.
Microtubules were then tracked using a custom LabVIEW tracking application written by Larry Herskowitz (KochLab). The tracking software (KochLab) used image segmentation algorithms to identify microtubule ends via pattern matching. Microtubules successfully tracked for fewer than 100 consective images were discarded. This lower bound of images was found through experiment to give reliable data. Microtubules that could be tracked with fewer images did not consistently give high fidelity data and thus a lower bound for images was set. The software was unable to track microtubules that had a segmented area less than 55 pixels due to the pattern matching algorithms used. This put a lower bound on the length of trackable microtubules to be around 2 μm. Finally, tracking of microtubules stopped if the microtubule crossed other microtubules or if it came too close to the edges of the field of view.


Once tracking was complete, the X and Y pixel values for the ends of microtubules were then analyzed with another custom LabVIEW analysis program again written by Larry Herskowitz. This program calculated the speeds at which microtubules were moving at by subtracting the pixel values of consecutive tracked microtubule images and dividing by the time between frames.
Once tracking was complete, the X and Y pixel values for the ends of microtubules were analyzed with another custom LabVIEW analysis program written by Larry Herskowitz and Steve Koch (KochLab). This program calculated the speeds at which microtubules were moving at by subtracting the pixel values of consecutive tracked microtubule images and dividing by the time between frames.
<center>
<center>
<math>
<math>
Line 186: Line 181:
</math>
</math>
</center>
</center>
These values are plotted in Figure 8 as the blue markers. As one can see, there is a lot of noise in these raw measurements. I believe that the cause is because microtubule ends are never permanently attached to the kinesin surface and thus undergo transient Brownian motion. To alleviate this noise, a sliding Gaussian window of 2 seconds was used to smooth the data. This newly smoothed data is depicted as the black curve in Figure 8. Boundary effects due to the finite sample size are quite evident in the graph. There are a lot of techniques that try to compensate for these edge effects, however, we as a group decided to not take them into consideration. Instead, we decided to remove 5 seconds worth of points from the beginning and end of the data set. This completely removed all the edge effects due to smoothing.
These values are plotted in Figure 8 as the blue markers. As one can see, there is a lot of noise in these raw measurements. I believe that the cause is because microtubule ends are never permanently attached to the kinesin surface and thus undergo Brownian motion transverse to the motility direction. To alleviate this noise, a sliding Gaussian window of 2 seconds was used to smooth the data. This newly smoothed data is depicted as the black curve in Figure 8. Boundary effects due to the finite sample size are quite evident in the graph. There are a lot of techniques that try to compensate for these edge effects, however, we as a group decided to not take them into consideration. Instead, we decided to remove 5 seconds worth of points from the beginning and end of the data set. This completely removed all the edge effects due to smoothing.
{| border="0" align="right" valign="bottom" cellpadding=10px   
{| border="0" align="right" valign="bottom" cellpadding=10px   
|-
|-
| align="left" | [[Image:AM AlphaCaseinSmoothedData.jpg|300px]]
| align="left" | [[Image:AM AlphaCaseinSmoothedData.jpg|300px]]
|-
|-
| align="left" valign="top" width="300" | '''Figure 8:''' Data analysis. Blue markers are X and Y data points tracked by the tracking program. They have been converted to speed values. The black curve is the smoothed data using a Gaussian window with a width of 2 seconds. The red curve is the data that is then analyzed by the KDE algorithm.
| align="left" valign="top" width="300" | '''Figure 8:''' Data analysis. Blue markers are the speed values from unsmoothed X and Y positions of the microtubule end. The black curve shows the speed values calculated after smoothing the position data using a Gaussian window with a width of 2 seconds. The red curve shows the speed data after removing the first and last 5 second time periods and is the data that is then analyzed by the KDE algorithm.
|-
|-
| align="left" | [[Image:AM AlphaCaseinKDEData.jpg|300px]]
| align="left" | [[Image:AM AlphaCaseinKDEData.jpg|300px]]
|-
|-
| align="left" valign="top" width="300" | '''Figure 9:''' KDE of a single microtubule using alpha casein passivation.
| align="left" valign="top" width="300" | '''Figure 9:''' KDE of a single microtubule gliding speed using alpha casein passivation.
|}
|}
Automated tracking provided the x and y position with subpixel accuracy of the microtubule ends for each frame that was tracked, see Figure 8. These time series data (blue markers) were smoothed (black line) with a sliding Gaussian window with a standard deviation of 2 seconds. Smoothed data points that were within 5 seconds of the beginning or end of the tracks were discarded (red line) in order to eliminate window boundary effects on the smoothed data. Smoothing the position versus time data was necessary since the microtubule ends are never permanently attached to the kinesin surface and thus undergo transient Brownian motion. After smoothing and truncating, the instantaneous speed was calculated as the distance per time between consecutive frames.
Kernel density estimation (KDE) (Silverman 1986) was then done on all the individual microtubules. Making a KDE is very similar to making a histogram of the speed data. Except that the KDE method applies a Gaussian kernel around every point instead of placing a data point in a bin. The Gaussians are then summed together to give a smooth representation of what the most likely microtubule speed is. Figure 9 shows the KDE of the microtubule data in Figure 8. The bandwidth used in this kernel was 20 nm/s. As you can see in Figure 8, The smoothed red line data is not completely flat. This is because the microtubule does not travel at the same speed all the time. It can pause, stop completely, or even slow down. Using the KDE method allows one to see these subtle differences in speeds and is quite evident in Figure 9.


Kernel density estimation (KDE) (Silverman 1968) was then done on all the individual microtubules. Making a KDE is very similar to making a histogram of the speed data. Except that the KDE method applies a Gaussian kernel around every point instead of placing a data point in a bin. The Gaussians are then summed together to give a smooth representation of what the microtubule speed is. Figure 9 shows the KDE of the microtubule data in Figure 8. The bandwidth used in this kernel was 20 nm/s. As you can see in Figure 8, The smoothed red line data is not completely flat. This is because the microtubule does not travel at the same speed all the time. It can pause, stop completely, or even slow down. Using the KDE method allows one to see these subtle differences in speeds and is quite evident in Figure 9. My present study was to look at the average or most probable speeds a microtubule will travel at using different passivation schemes. This is why I took the most likely speed a single microtubule traveled at and used that speed for the next step in the analysis.
Speed versus time data for all the microtubules in an individual region of interest (ROI) were then concatenated together (all the smoothed data similar to Figure 8) and the most likely speed for a ROI was extracted using the KDE method with a Gaussian kernel of width 50 nm/s. Using the KDE method instead of a simple mean reduces the sensitivity to microtubule pausing or stalling, which was evident in many assays. We used a large kernel width to reduce sensitivity to possible speed changes due to number of kinesin motors or other causes (Gagliano 2010). The most likely speeds for individual regions were then plotted versus time to determine when the slide had reached thermal equilibrium with the objective, see Figure 6. The initial 5 data points were removed for all data sets indicating that it took about 10 minutes for the slide to reach a stable temperature. Each assay; alpha, beta, kappa, whole, and mixed casein was repeated 3 separate times on different days and with different kinesin aliquots. When possible, the mean and standard error of the mean was computed for the three data points for a given assay time.
 
<br style="clear:both;"/>
Speed versus time data for all the microtubules in an individual region of interest (ROI) were then concatenated together and the most likely speed for a ROI was extracted using the KDE method with a Gaussian kernel of width 50 nm/s. Using the KDE method instead of a simple mean reduces the sensitivity to microtubule pausing or stalling, which was evident in many assays. We used a large kernel width to reduce sensitivity to possible speed changes due to number of kinesin motors or other causes (Gagliano 2010). The most likely speeds for individual regions were then plotted versus time to determine when the slide had reached thermal equilibrium with the objective, see Figure 6. The initial 5 data points were removed for all data sets indicating that it took about 10 minutes for the slide to reach a stable temperature. Each assay; alpha, beta, kappa, whole, and mixed casein was repeated 3 separate times on different days and with different kinesin aliquots. When possible, the mean and standard error of the mean was computed for the three data points for a given assay time.
 
<html>
<br />
<br />
</html>


==Results and discussion==
==Results and discussion==
===Results===
===Results===
Data was taken at 33.1 ± 0.1°C as measured from the top thermistor on the objective. This temperature is well above the temperature the objective would reach due to long-term heating, see Figure 3, from the Hg lamp and was found to give consistent data, Figure 6. I observed that the closer the observation was to the boundaries of the flow cell, the slower the microtubule gliding speed was and, that the propensity for depolymerization increased near the boundaries. In order to obtain consistent data and prevent depolymerization of the microtubules, gliding assays were observed in the center of the flow cell channel, except where otherwise noted. All images have had dead pixels removed by an interpolation function and have been false colored using ImageJ’s green fire blue LUT using a custom LabVIEW 7.1 application.
Data was taken at 33.1 ± 0.1°C as measured from the top thermistor on the objective. This temperature is well above the temperature the objective would reach due to long-term heating, see Figure 3, from the Hg lamp and was found to give consistent data, Figure 6. I observed that the closer the ROI was to the boundaries of the flow cell, the slower the microtubule gliding speed was. I also observed that the propensity for depolymerization increased near the boundaries of the flow cell. In order to obtain consistent data and prevent depolymerization of the microtubules, gliding assays were observed in the center of the flow cell channel, except where otherwise noted. All images have had dead pixels removed by an interpolation function and have been false colored using ImageJ's green fire blue LUT using a custom LabVIEW 7.1 application written by Larry Herskowitz (KochLab).


Bovine alpha casein (a mixture of α<sub>s1</sub> 37% and α<sub>s2</sub> 10%) constitutes approximately 47% of whole bovine casein (Fox 1998 Ch. 4). This passivation was capable of supporting small microtubules and longer ones as can be seen in Figure 10. When using alpha casein, the gliding motility assay worked every time except when the kinesin or antifade system lost its effectiveness for maintaining a gliding assay. Movie 1 shows a typical gliding assay using alpha casein as the surface passivator.
Bovine alpha casein (a mixture of α<sub>s1</sub>, 37% and α<sub>s1</sub>, 10%) constitutes approximately 47% of whole bovine casein (Fox 1998a). This passivation was capable of supporting small microtubules and longer ones as can be seen in Figure 10 & 11. When using alpha casein, the gliding motility assay worked every time except when the kinesin or antifade system lost its effectiveness for maintaining a gliding assay.
{| border="0" align="center" valign="bottom" cellpadding=10px   
{| border="0" align="center" valign="bottom" cellpadding=10px   
|-
|-
Line 219: Line 208:
|-
|-
| align="left" valign="top" width="300" | '''Figure 10:''' Typical image from a gliding motility assay using alpha casein as the surface passivator.
| align="left" valign="top" width="300" | '''Figure 10:''' Typical image from a gliding motility assay using alpha casein as the surface passivator.
| align="left" valign="top" width="300" | '''Movie 1:''' Typical movie from a gliding motility assay using alpha casein as the surface passivator.
| align="left" valign="top" width="300" | '''Figure 11:''' Typical movie from a gliding motility assay using alpha casein as the surface passivator.
|}
|}
Bovine beta casein comprises approximately 35% of whole casein and visible precipitates took less time to dissolve in PEM as compared to alpha casein. Figure 11 shows that beta casein as a surface passivator was not ideal. It did not support smaller microtubules and did not in general have very many motile microtubules in any assay. The microtubules that were motile, were typically quite long. Beta casein also caused the microtubule’s minus and positive ends to detach from the kinesin surface while undergoing motility more often than the other passivation schemes. This caused errors in the tracking and thus did not give consistent data. This is unfortunate as it can be purified to better than 98% making this component of whole casein the purest commercially available. Another interesting phenomenon observed when using beta casein was that motile microtubules were not found in the center of the channel for the flow cell. Motile microtubules were observed, but they were always found off center to the flow cell channel. I am not sure of the reason for this but, it may depend on kinesin or casein concentration. I did not vary the input kinesin or casein concentration for these studies.  
Bovine beta casein comprises approximately 35% of whole casein and visible precipitates took less time to dissolve in PEM as compared to alpha casein. Figure 12 & 13 shows that beta casein as a surface passivator was not ideal. It did not support smaller microtubules and did not in general have very many motile microtubules in any assay. The microtubules that were motile, were typically quite long. Beta casein also caused the microtubule's minus and positive ends to detach from the kinesin surface while undergoing motility more often than the other passivation schemes. This caused errors in the tracking and thus did not give consistent data. This is unfortunate as it can be purified to better than 98% making this component of whole casein the purest commercially available. Another interesting phenomenon observed when using beta casein was that motile microtubules were not found in the center of the channel for the flow cell. Motile microtubules were observed, but they were always found off center to the flow cell channel. I am not sure of the reason for this but, it may depend on kinesin or casein concentration. I did not vary the input kinesin or casein concentration for these studies.
{| border="0" align="center" valign="bottom" cellpadding=10px   
{| border="0" align="center" valign="bottom" cellpadding=10px   
|-
|-
Line 227: Line 216:
| align="left" | <html><object width="300" height="300"><param name="movie" value="http://www.youtube.com/v/6IXpaC_mqZk?fs=1&amp;hl=en_US"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="http://www.youtube.com/v/6IXpaC_mqZk?fs=1&amp;hl=en_US" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="300" height="300"></embed></object></html>
| align="left" | <html><object width="300" height="300"><param name="movie" value="http://www.youtube.com/v/6IXpaC_mqZk?fs=1&amp;hl=en_US"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="http://www.youtube.com/v/6IXpaC_mqZk?fs=1&amp;hl=en_US" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="300" height="300"></embed></object></html>
|-
|-
| align="left" valign="top" width="300" | '''Figure 11:''' Typical image from a gliding motility assay using beta casein as the surface passivator.
| align="left" valign="top" width="300" | '''Figure 12:''' Typical image from a gliding motility assay using beta casein as the surface passivator.
| align="left" valign="top" width="300" | '''Movie 1:''' Typical movie from a gliding motility assay using beta casein as the surface passivator.
| align="left" valign="top" width="300" | '''Figure 13:''' Typical movie from a gliding motility assay using beta casein as the surface passivator.
|}
|}
Kappa casein, compared to alpha and beta, is structurally very different. It is a glycoprotein and is thought to stabilize the casein micelle (Fox 1998 Ch. 4, Walstra 1999, Phadungath 2005) by sterically hindering the aggregation of too many casein sub-micelles. It did not support motility in a very consistent manner as can be seen from Figure 12. As was the case for beta casein, kappa casein did not support motility in the center of the channel of the flow cell. Stuck microtubules were found near the center of the flow cell and near the tape. However, between the boundaries of the flow cells and away from the center of it, there was motility. In the areas that motility existed, kappa casein was able to support motility of long and short microtubules with the exception of extremely short microtubules found to move only in the alpha or whole casein assays. The very short microtubules either remained stuck to the surface or exhibited motility for a very short period of time before going into solution. Kappa casein did a remarkable job of adhering microtubules to the slide much like how poly-L-lysine is used to fix microtubules on a slide (Vater 1995).
Kappa casein, compared to alpha and beta, is structurally very different. It is a glycoprotein and is thought to stabilize the casein micelle (Fox 1998a, Walstra 1999, Phadungath 2005) by sterically hindering the aggregation of too many casein sub-micelles. It did not support motility in a very consistent manner as can be seen from Figure 14 & 15. As was the case for beta casein, kappa casein did not support motility in the center of the channel of the flow cell. Stuck microtubules were found near the center of the flow cell and near the tape. However, between the boundaries of the flow cells and away from the center of it, there was motility. In the areas that motility existed, kappa casein was able to support motility of long and short microtubules with the exception of extremely short microtubules found to move only in the alpha or whole casein assays. The very short microtubules either remained stuck to the surface or exhibited motility for a very short period of time before going into solution. Kappa casein did a remarkable job of adhering microtubules to the slide much like how poly-L-lysine is used to fix microtubules on a slide (Vater 1995).
{| border="0" align="center" valign="bottom" cellpadding=10px   
{| border="0" align="center" valign="bottom" cellpadding=10px   
|-
|-
Line 236: Line 225:
| align="left" | <html><object width="300" height="300"><param name="movie" value="http://www.youtube.com/v/s6cATn48z3Y?fs=1&amp;hl=en_US"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="http://www.youtube.com/v/s6cATn48z3Y?fs=1&amp;hl=en_US" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="300" height="300"></embed></object></html>
| align="left" | <html><object width="300" height="300"><param name="movie" value="http://www.youtube.com/v/s6cATn48z3Y?fs=1&amp;hl=en_US"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="http://www.youtube.com/v/s6cATn48z3Y?fs=1&amp;hl=en_US" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="300" height="300"></embed></object></html>
|-
|-
| align="left" valign="top" width="300" | '''Figure 12:''' Typical image from a gliding motility assay using kappa casein as the surface passivator.
| align="left" valign="top" width="300" | '''Figure 14:''' Typical image from a gliding motility assay using kappa casein as the surface passivator.
| align="left" valign="top" width="300" | '''Movie 1:''' Typical movie from a gliding motility assay using kappa casein as the surface passivator.
| align="left" valign="top" width="300" | '''Figure 15:''' Typical movie from a gliding motility assay using kappa casein as the surface passivator.
|}
|}
Whole bovine casein is the passivator of choice when doing gliding motility experiments. We found that whole bovine casein worked remarkably well for sustaining motility. Similar to the alpha casein passivation, whole casein worked every single time and gave consistent data. It was only when we deemed either the kinesin or the antifade system to have lost its effectiveness at maintaining microtubule gliding that the assay did not work. Of the 5 types of bovine casein solutions tested, whole casein required heat in order for visible precipitate to completely dissolve in was the most difficult to get into a solution of PEM. See the supplemental information for a more thorough discussion of how we dissolve whole casein in PEM. We did not observe any adverse affects to motility by heating whole casein. Whole casein supported long and short microtubule motility as shown in Figure 1 E.
Whole bovine casein is the passivator of choice when doing gliding motility experiments. Whole bovine casein worked remarkably well for sustaining motility, Figure 15 & 17. Similar to the alpha casein passivation, whole casein worked every single time and gave consistent data. It was only when we deemed either the kinesin or the antifade system to have lost its effectiveness at maintaining microtubule gliding that the assay did not work. Of the 5 types of bovine casein solutions tested, whole casein required heat in order for visible precipitate to completely dissolve into a solution of PEM. I did not observe any adverse affects to motility by heating whole casein.
{| border="0" align="center" valign="bottom" cellpadding=10px   
{| border="0" align="center" valign="bottom" cellpadding=10px   
|-
|-
Line 245: Line 234:
| align="left" | <html><object width="300" height="300"><param name="movie" value="http://www.youtube.com/v/LV9ELcgZT6I?fs=1&amp;hl=en_US"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="http://www.youtube.com/v/LV9ELcgZT6I?fs=1&amp;hl=en_US" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="300" height="300"></embed></object></html>
| align="left" | <html><object width="300" height="300"><param name="movie" value="http://www.youtube.com/v/LV9ELcgZT6I?fs=1&amp;hl=en_US"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="http://www.youtube.com/v/LV9ELcgZT6I?fs=1&amp;hl=en_US" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="300" height="300"></embed></object></html>
|-
|-
| align="left" valign="top" width="300" | '''Figure 12:''' Typical image from a gliding motility assay using whole casein as the surface passivator.
| align="left" valign="top" width="300" | '''Figure 16:''' Typical image from a gliding motility assay using whole casein as the surface passivator.
| align="left" valign="top" width="300" | '''Movie 1:''' Typical movie from a gliding motility assay using whole casein as the surface passivator.
| align="left" valign="top" width="300" | '''Figure 17:''' Typical movie from a gliding motility assay using whole casein as the surface passivator.
|}
|}
Mixing whole casein from the individual constituents of alpha, beta, and kappa was also used as a surface passivator. The mixed whole casein consisted of 49% alpha casein, 37% beta casein and, 14% kappa casein which is very similar to what Fox and McSweeney state as the casein components of bovine milk (Fox 1998 Ch. 4). Mixing it was easy since each component was already in a PEM solution. The behavior of the mixed bovine whole casein was indistinguishable from the purchased whole casein or the alpha casein passivation. The number of microtubules and the varying lengths undergoing motility in the mixed casein passivation was very similar to those of the whole casein passivation as well.
Mixing whole casein from the individual constituents of alpha, beta, and kappa was also used as a surface passivator. The mixed whole casein consisted of 49% alpha casein, 37% beta casein and, 14% kappa casein which is very similar to what Fox and McSweeney state as the casein components of bovine milk (Fox 1998a). Mixing it was easy since each component was already in a PEM solution. The behavior of the mixed bovine whole casein was indistinguishable from the purchased whole casein or the alpha casein passivation, Figure 18 & 19.
{| border="0" align="center" valign="bottom" cellpadding=10px   
{| border="0" align="center" valign="bottom" cellpadding=10px   
|-
|-
Line 254: Line 243:
| align="left" | <html><object width="300" height="300"><param name="movie" value="http://www.youtube.com/v/C6CjWUu1E0k?fs=1&amp;hl=en_US"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="http://www.youtube.com/v/C6CjWUu1E0k?fs=1&amp;hl=en_US" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="300" height="300"></embed></object></html>
| align="left" | <html><object width="300" height="300"><param name="movie" value="http://www.youtube.com/v/C6CjWUu1E0k?fs=1&amp;hl=en_US"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="http://www.youtube.com/v/C6CjWUu1E0k?fs=1&amp;hl=en_US" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="300" height="300"></embed></object></html>
|-
|-
| align="left" valign="top" width="300" | '''Figure 12:''' Typical image from a gliding motility assay using mixed casein as the surface passivator.
| align="left" valign="top" width="300" | '''Figure 18:''' Typical image from a gliding motility assay using mixed casein as the surface passivator.
| align="left" valign="top" width="300" | '''Movie 1:''' Typical movie from a gliding motility assay using mixed casein as the surface passivator.
| align="left" valign="top" width="300" | '''Figure 19:''' Typical movie from a gliding motility assay using mixed casein as the surface passivator.
|}
|}
Figure 13 shows the mean speed measurements for 15 different regions of interest for the alpha, beta, whole and mixed casein assays. Each region of interest is the mean and SEM from three separate samples. The passivator that gave the most consistent speed was alpha casein. The mean speed and SEM from our alpha casein measurement was 949 ± 4 nm/s. Purchased whole casein and mixed casein performed remarkably similarly and displayed average speed values of 966 ± 7 nm/s and 966 ± 7 nm/s respectively. Bovine beta casein performed poorly in comparison to alpha, whole, or mixed caseins and we measured the mean speed to be 870 ± 30 nm/s. Figure 14 shows the observed speeds for kappa casein passivation. Since there were so many areas where no motility was observed in this assay, it was difficult to determine a mean speed measurement for each ROI as was done in Figure 13. However, it does appear that when motile, the speeds were around 870-880 nm/s with kappa casein as the surface passivator. This was similar to how beta casein performed.
Figure 20 shows the mean speed measurements for 15 different regions of interest for the alpha, beta, whole and mixed casein assays. Each region of interest is the mean and SEM from three separate samples. The passivator that gave the most consistent speed was alpha casein. The mean speed and SEM from our alpha casein measurement was 949 ± 4 nm/s. Purchased whole casein and mixed casein performed remarkably similarly and displayed average speed values of 966 ± 7 nm/s and 966 ± 6 nm/s respectively. Bovine beta casein performed poorly in comparison to alpha, whole, or mixed caseins and we measured the mean speed to be 870 ± 30 nm/s.
 
Figure 21 shows the observed speeds for kappa casein passivation. Since there were so many areas where no motility was observed in this assay, it was difficult to determine a mean speed measurement for each ROI as was done in Figure 20. However, it does appear that when motile, the speeds were around 870-880 nm/s with kappa casein as the surface passivator. This was similar to how beta casein performed.
{| border="0" align="center" valign="bottom" cellpadding=10px   
{| border="0" align="center" valign="bottom" cellpadding=10px   
|-
|-
Line 263: Line 254:
| align="left" | [[Image:AM KappaCaseinSpeeds.jpg|300px]]
| align="left" | [[Image:AM KappaCaseinSpeeds.jpg|300px]]
|-
|-
| align="left" valign="top" width="300" | '''Figure 13:''' Black circles are alpha casein passivation, red squares are beta casein passivation, green right side up triangles are whole casein passivation, and blue upside down triangles are mixed casein passivation. Error bars are the standard error of the mean for each region in the flow cell where data was taken. Alpha casein has the most consistent average speed measurements at 949 ± 4 nm/s. Whole casein and mixed casein averaged to 966 ± 7 nm/s and 966 ± 6 nm/s respectively. And, beta casein averaged to 870 ± 30 nm/s. Errors in the average speed are the standard deviation from the average.
| align="left" valign="top" width="300" | '''Figure 20:''' Black circles are alpha casein passivation, red squares are beta casein passivation, green right side up triangles are whole casein passivation, and blue down pointing triangles are mixed casein passivation. Each data point is the mean for three ROIs from separate samples at the corresponding assay time point.  Error bars are the SEM of those three measurements. Alpha casein had the most consistent average speed measurements at 949 ± 4 nm/s. Whole casein and mixed casein averaged to 966 ± 7 nm/s and 966 ± 6 nm/s respectively. Beta casein averaged to ± 30 nm/s.
| align="left" valign="top" width="300" | '''Figure 14:''' Green squares, red circles, and blue triangles represent 3 different assays. As the figure shows, kappa casein is not the ideal surface passivator. There are many regions in the flow cell where no motility exists at all and other areas where motility can give quasi consistent results. Albeit at much slower speeds than is reported from alpha, whole or mixed casein passivations. The open black circles show a characteristic alpha casein assay for comparison. Note that the initial increase in speed is due to the slide coming to thermal equilibrium with the objective.
| align="left" valign="top" width="300" | '''Figure 21:''' Green squares, red circles, and blue triangles represent 3 different assays. As the figure shows, kappa casein is not an ideal surface passivator. There are many regions in the flow cell where no motility exists at all and other areas where motility can give quasi consistent results. Albeit at much slower speeds than is reported from alpha, whole or mixed casein passivations. The open black circles show a characteristic alpha casein assay for comparison. Note that the initial increase in speed is due to the slide coming to thermal equilibrium with the objective.
|}
|}
{| border="0" align="right" valign="bottom" cellpadding=10px   
{| border="0" align="right" valign="bottom" cellpadding=10px   
Line 270: Line 261:
| align="left" | [[Image:AM PassivationLengths.jpg|300px]]
| align="left" | [[Image:AM PassivationLengths.jpg|300px]]
|-
|-
| align="left" valign="top" width="300" | '''Figure 15:'''Filled blue bars are length calculations for the alpha casein passivation, filled green bars are for the beta casein passivation, filled red bars are for the kappa casein passivation, unfilled black bars are for the mixed casein passivation, and unfilled purple bars are for the whole casein passivation. Length measurements were performed only on tracked microtubules and are estimations from computing the Convex Hull perimeter on eroded images of microtubules.
| align="left" valign="top" width="300" | '''Figure 22:''' Filled blue bars are length calculations for the alpha casein passivation, filled green bars are for the beta casein passivation, filled red bars are for the kappa casein passivation, unfilled black bars are for the mixed casein passivation, and unfilled purple bars are for the whole casein passivation. Length measurements were performed only on tracked microtubules and are estimations from computing the Convex Hull perimeter on eroded images of microtubules.
|}
|}
Figure 15 shows a histogram of microtubule lengths. To obtain lengths, an erosion algorithm was used on binary images of only the microtubules that were tracked. The erosion algorithm comes as a standard function in LabVIEW 7.1. The “skeleton” algorithm, as it is called in LabVIEW, is not optimized for measuring microtubule lengths and tended to overestimate them. Because of this, another algorithm was used on the “skeletonized” microtubules, namely a Convex Hull perimeter calculation, also found in the LabVIEW library of functions. Dividing the Convex Hull perimeter by 2 gave lengths that consistently fell in between manual measurements done my myself and Koch. As can be seen in the figure, alpha casein (filled blue bars), whole casein (empty purple line bars) and mixed casein (empty black line bars) all were able to sustain motility with smaller microtubules 2 - 6 µm range. Beta casein (filled green bars) had significantly fewer microtubules that were tracked, however, those that were tended to be longer than the ones tracked in the alpha casein assay. Kappa casein (filled red bars) show that there were many more trackable microtubules than beta casein and significantly fewer than alpha casein. The smallest trackable microtubules using our algorithm are not smaller than 2 µm. Figure 2 shows that while in comparison to the other lengths, there are relatively few 2 µm microtubules in any of the assays, kappa casein had no microtubules that fell in the 2 - 3 µm range. There is, however, a larger number of kappa casein microtubules that were in the 20 - 21 µm range as compared to the other assays. Length measurements using this method are not optimized for precision. This method does, however, give a simple way to see the relative size distribution differences in the assays.
Figure 22 shows a histogram of microtubule lengths. To obtain lengths, an erosion algorithm was used on binary images of only the microtubules that were tracked. The erosion algorithm comes as a standard function in LabVIEW 7.1. The skeleton algorithm, as it is called in LabVIEW, is not optimized for measuring microtubule lengths and tended to overestimate them. Because of this, another algorithm was used on the skeletonized microtubules, namely a Convex Hull perimeter calculation, also found in the LabVIEW library of functions. Dividing the Convex Hull perimeter by 2 gave lengths that consistently fell in between manual measurements done by myself and Koch. As can be seen in the figure, alpha casein (filled blue bars), whole casein (empty purple line bars) and mixed casein (empty black line bars) all were able to sustain motility with smaller microtubules 2 --- 6 μm range. Beta casein (filled green bars) had significantly fewer microtubules that were tracked, however, those that were tended to be longer than the ones tracked in the alpha casein assay. Kappa casein (filled red bars) had many more trackable microtubules than beta casein but significantly fewer than alpha casein. The smallest trackable microtubules using our image segmentation algorithm are around 2 μm. Figure 22 shows that there are relatively few 2 μm microtubules in any of the assays. Kappa casein, however, had no microtubules that fell in the 2 --- 3 μm range but it had a large number of microtubules that were in the 20 --- 21 μm range. Length measurements using this method are not optimized for precision. This method does give a way to see the relative size distribution differences in the assays.
<br style="clear:both;"/>


===Discussion===
===Discussion===
It would appear that the more difficult it was to dissolve casein, the better it worked as a surface passivator. This may be a coincidence, or it may relate to the manner in which casein adsorbs to the glass. Whole casein was by far the most difficult to dissolve visible precipitate into PEM without heating. Alpha casein came in second, beta third and kappa fourth in terms of the time to dissolve completely in PEM at room temperature. Whole casein is approximately 50% alpha casein and seeing how well alpha casein performed as a surface passivator, it was not surprising to find that whole casein also performed well. The differences in measured speeds between alpha and whole casein could be a result of how kinesin is supported by the different caseins, or it could be due to differences in surface-coverage for passivation by the casein. It has been shown that using substrates of differing hydrophilicity with whole casein passivation affects the activity of kinesin (Huang 2005). This is a very interesting result and could be an indication that kinesin likes to adsorb to the casein and not the substrate. And, the hydrophobicity of the surface could influence how casein adheres to it ultimately affecting the gliding motility assay.
It would appear that the more difficult it was to dissolve casein, the better it worked as a surface passivator. This may be a coincidence, or it may relate to the manner in which casein adsorbs to the glass. Whole casein was by far the most difficult to dissolve visible precipitate into PEM without heating. Alpha casein came in second, beta third and kappa fourth in terms of the time to dissolve completely in PEM at room temperature. Whole casein is approximately 50% alpha casein and seeing how well alpha casein performed as a surface passivator, it was not surprising to find that whole casein also performed well. The differences in measured speeds between alpha and whole casein could be a result of how kinesin is supported by the different caseins, or it could be due to differences in surface-coverage for passivation by the casein. It has been shown that using substrates of differing hydrophilicity with whole casein passivation affects the activity of kinesin (Huang 2005).


Purchased whole and mixed whole casein were practically indistinguishable. They performed almost identically and had the same measured speeds. Mixed whole casein has an upper bound of 20% impurities in it. This amount is very similar to the amount of impurities alpha casein has in it yet, mixed whole casein performed exactly how purchased whole casein did. This similarity between mixed and purchased whole casein suggests that the speed difference between alpha and whole casein is not due to impurities but rather that it is due to how kinesin is supported by the casein micelles or, how casein interacts with the glass. To elucidate the effects, it would be prudent to measure the speeds for the various caseins as a function of casein and kinesin concentrations during incubation. I have not performed these experiments.
Purchased whole and mixed casein were practically indistinguishable. They performed almost identically and had the same measured speeds. Mixed whole casein has an upper bound of 20% impurities in it. This amount is very similar to the amount of impurities alpha casein has in it yet, mixed whole casein performed exactly how purchased whole casein did. This similarity between mixed and purchased whole casein suggests that the speed difference between alpha and whole casein is not due to impurities but rather that it is due to how kinesin is supported by the casein micelles or, how casein interacts with the glass. To elucidate this effect, it would be prudent to measure the speeds for the various caseins as a function of casein and kinesin concentrations during incubation. I have not performed these experiments.


Beta casein would have been the most ideal protein to use as the surface passivator since it can be purified to greater than 98% purity. Higher protein purity is advantageous for systematically producing devices that use kinesin and microtubules as sensors. However, beta casein did not perform very well. It had the least number of motile microtubules to track, it was not very reliable, and had a large distribution in speeds. It is possible, though, that varying other parameters such as kinesin concentration, or beta casein concentration could restore reliable motility. Again, these are future experiments.
Beta casein would have been the most ideal protein to use as the surface passivator since it can be purified to greater than 98% purity. Higher protein purity is advantageous for systematically producing devices that use kinesin and microtubules as sensors. However, beta casein did not perform very well. It had the least number of motile microtubules to track, it was not very reliable, and had a large distribution in speeds. It is possible, though, that varying other parameters such as kinesin concentration, or beta casein concentration could restore reliable motility. Again, these are future experiments.


Kappa casein would be an attractive surface passivator just for its ease in dissolving in PEM. However, where motility exists in the flow cell is not consistent and it never occurs in the center of the channel where I have observed the most consistent speed measurements from other assays. With kappa casein, many long and stable microtubules permanently stuck to the surface. I am not sure if the sticking is caused from kinesin attaching to microtubules and then somehow being impeded from moving or, if there is actually no kinesin on the kappa casein surface and the microtubules are just attracted to the kappa casein or glass. Remember that kappa caseins are glycoproteins are are structurally very different than the other casein constituents.
Kappa casein would be an attractive surface passivator just for its ease in dissolving in PEM. However, where motility exists in the flow cell is not consistent and it never occurs in the center of the channel where I have observed the most consistent speed measurements from other assays. With kappa casein, many long and stable microtubules permanently stuck to the surface. I am not sure if the sticking is caused from kinesin attaching to microtubules and then somehow being impeded from moving or, if there is actually no kinesin on the kappa casein surface and the microtubules are just attracted to the kappa casein or glass.


Of the five types of bovine casein used to observe the gliding motility assay, alpha casein performed very well. It is the easiest of the three commercially available bovine casein constituents to dissolve in PEM and can be purchased at 70% purity. Most likely, the 30% contaminants are from other casein components. It performed well every time an assay was prepared and worked just as well as mixed and purchased whole casein.
Of the five types of bovine caseins used to observe the gliding motility assay, alpha casein performed very well. It is the easiest of the three commercially available bovine casein constituents to dissolve in PEM and can be purchased at 70% purity. Most likely, the 30% contaminants are from other casein components. It performed well every time an assay was prepared and worked just as well as mixed and purchased whole casein.
<br style="clear:both;"/>


==Conclusion==
==Conclusion==
There are a wide variety of surface passivation strategies in the literature. This study showed that there are differences in how the gliding motility assay is observed dependent on the type of passivaiton used. Bovine alpha casein was the most reliable passivator when following the most typical gliding assay protocol found in [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page Chapter 2. This is why I have chosen to use it for my following studies using isotopes of water in the gliding motility assay.
<br style="clear:both;"/>
==Future work==
There are a great number of experiments that could be done to further this line of research. For instance, varying the amount of kinesin used in each assay could illuminate more characteristics of how kinesin interacts with the surface passivation. Also, varying the casein constituent concentration used to passivate the surface could bring to light the possibility that either beta or kappa casein is a better surface passivator than alpha casein. And finally, since the individual constituents of bovine casein can be purchased separately, one can devise experiments that uses engineered ''whole casein'' as the surface passivation. One could even use dephosphorylated alpha or beta casein as components to the engineered surface passivation.


There are a wide variety of surface passivation strategies in the literature. Even for use with kinesin in the gliding motility assays there exists choices for the casein to use as the passivator. Bovine alpha casein was the most reliable passivator when following the most typical gliding assay protocol found in [[User:Andy_Maloney/Kinesin_%26_Microtubule_Page|Chapter 1]]. This is why I have chosen it to be used for my following studies using isotopes of water in the gliding motility assay.
<font size=3>[http://www.openwetware.org/wiki/User:Andy_Maloney#Dissertation '''Return to the table of contents.''']</font>


==Future work==
<font size=3>[http://www.openwetware.org/wiki/User:Andy_Maloney/Water_isotope_effects_on_kinesin_and_microtubules '''Forward to Chapter 3.''']</font>
There are a great number of experiments that could be done to further this line of research. For instance, varying the amount of kinesin used in each assay could illuminate more characteristics of how kinesin interacts with the surface passivation. Also, varying the casein constituent concentration used to passivate the surface could bring to light the possibility that either beta or kappa casein is a better surface passivator than alpha casein. And finally, since the individual constituents of bovine casein can be purchased separately, one can devise experiments that uses engineered "whole casein" as the surface passivation. One could even use dephosphorylated alpha or beta casein as components to the engineered surface passivation.
<br style="clear:both;"/>


==References==
==References==
* Alberty, R. A. (1968). [http://www.jbc.org/content/243/7/1337.short Effect of pH and metal ion concentration on the equilibrium hydrolysis of adenosine triphosphate to adenosine diphosphate]. ''The Journal of Biological Chemistry'', 243(7), 1337-1343.
* Berliner, E., Young, E., Anderson, K., Mahtani, H., & Gelles, J. (1995). [http://dx.doi.org/10.1038/373718a0 Failure of a single-headed kinesin to track parallel to microtubule protofilaments]. ''Letters to Nature'', 373(23), 718-721. doi: 10.1038/373718a0.
* Bingham, E. W. (1971). [http://dx.doi.org/10.3168/jds.S0022-0302(71)85974-X Influence of temperature and pH on the solubility of α<sub>s1</sub>-, β- and κ-casein]. ''Journal of Dairy Science'', 54(7), 1077-1080.
* Block, SM, Goldstein, LSB, & Schnapp, BJ (1990). [http://dx.doi.org/10.1038/348348a0 Bead movement by single kinesin molecules studied with optical tweezers]. ''Nature'', 348, 348-352. doi: 10.1038/348348a0.
* Bohm, K. J., Steinmetzer, P., Daniel, A., Baum, M., Vater, W., & Unger, E. (1997). [http://www.ncbi.nlm.nih.gov/pubmed/9227852 Kinesin-driven microtubule motility in the presence of alkaline-earth metal ions: indication for a calcium ion-dependent motility]. ''Cell motility and the cytoskeleton'', 37(3), 226-31.
* Bohm, K. J., Stracke, R., Baum, M., Zieren, M., & Unger, E. (2000). [http://dx.doi.org/10.1016/S0014-5793(99)01757-3 Effect of temperature on kinesin driven microtubule gliding and kinesin ATPase activity]. ''FEBS letters'', 466(1), 59-62. doi: 10.1016/S0014-5793(99)01757-3.
* Bohm, K. J., Stracke, R., & Unger, E. (2000). [http://dx.doi.org/10.1006/cbir.1999.0515 Speeding up kinesin-driven microtubule gliding in vitro by variation of cofactor composition and physicochemical parameters]. ''Cell biology international'', 24(6), 335-41. doi: 10.1006/cbir.1999.0515.
* Carter, N. J., & Cross, R. A. (2005). [http://dx.doi.org/10.1038/nature03528 Mechanics of the kinesin step]. ''Nature'', 435(7040),308-12. doi: 10.1038/nature03528.
* Fox, P., & McSweeney, P. (1998). Chapter 4: Milk Proteins. [http://lccn.loc.gov/97077281 ''Dairy Chemistry and Biochemistry''] (1st ed., pp. 146-238). London: Blackie Academic & Professional.
* Fox, P., & McSweeney, P. (1998). Chapter 9: Heat-induced changes in milk. [http://lccn.loc.gov/97077281 ''Dairy Chemistry and Biochemistry''] (1st ed., pp. 347-378). London: Blackie Academic & Professional.
* Gagliano, J., Walb, M., Blaker, B., Macosko, J. C., & Holzwarth, G. (2010). [http://dx.doi.org/10.1007/s00249-009-0560-8 Kinesin velocity increases with the number of motors pulling against viscoelastic drag]. ''European biophysics journal: EBJ'', 39(5), 801-13. doi: 10.1007/s00249-009-0560-8.
* Gelles, J., Schnapp, B. J., & Sheetz, M. P. (1988). [http://dx.doi.org/10.1038/331450a0 Tracking kinesin-driven movements with nanometre scale precision]. ''Nature'', 331(6155), 450-3. doi: 10.1038/331450a0.
* Goldstein, L. S. B., & Philp, A. V. (1999). [http://www.ncbi.nlm.nih.gov/pubmed/10611960 The road less traveled: emerging principles of kinesin motor utilization]. ''Annual review of cell and developmental biology'', 15, 141-183.
* Hua, W., Young, E., Fleming, M., & Gelles, J. (1997). [http://www.nature.com/nature/journal/v388/n6640/abs/388390a0.html Coupling of kinesin steps to ATP hydrolysis]. ''Nature'', 388, 390-393.
* Huang, Y., Uppalapati, M., Hancock, W. O. & Jackson, T. N. (2005). [http://dx.doi.org/10.1109/TADVP.2005.858330 Microfabricated capped channels for biomolecular motor-based transport]. ''IEEE Transactions on Advanced Packaging'', 28(4), 564-570. doi: 10.1109/TADVP.2005.858330.
* Hunt, A., Gittes, F., & Howard, J. (1994). [http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1225420/ The force exerted by a single kinesin molecule against a viscous load]. ''Biophysical journal'', 67(2), 766-781.
* (Kinesin home page) [http://www.cellbio.duke.edu/kinesin/ Kinesin home page] http://www.cellbio.duke.edu/kinesin/.
* (KochLab) [http://kochlab.org/files/Software/Microtubule%20software/ Links to software used in this thesis]. http://kochlab.org/files/Software/Microtubule%20software/.
* Leclerc, E., & Calmettes, P. (1997). [http://dx.doi.org/10.1103/PhysRevLett.78.150 Interactions in micellar solutions of β-casein]. ''Physical Review Letters'', 78(1), 150-153. doi: 10.1103/PhysRevLett.78.150.
* Mahamdeh, M., & Schaffer, E. (2009). [http://dx.doi.org/10.1364/OE.17.017190 Optical tweezers with millikelvin precision of temperature-controlled objectives and base-pair resolution]. ''Optics Express'', 17(19), 17190. doi: 10.1364/OE.17.017190.
* Maloney, A., Herskowitz, L. J., & Koch, S. (Corrected) (2010) [http://dx.doi.org/10.1038/npre.2010.4469.2 Speed effects in gliding motility assays due to surface passivation, water isotope, and osmotic stress]. Available from ''Nature Precedings''.
* O'Connell, J. E., Grinberg, V. Y., & de Kruif, C. G. (2003). [http://dx.doi.org/10.1016/S0021-9797(02)00066-8 Association behavior of β-casein]. ''Journal of Colloid and Interface Science'', 258(1), 33-39. doi: 10.1016/S0021-9797(02)00066-8.
* Payens, T. A. J., & van Markwijk, B. W. (1963). [http://www.mendeley.com/research/some-features-association-casein?utm_source=desktop&utm_medium=0.9.8.2&utm_campaign=open_catalog&userDocumentId={ba53c9e4-fd1a-4529-bb15-905e99e9b5ad} Some features of the association of β-casein]. ''Biochimica et Biophysica Acta'', 71, 517-530.
* Phadungath, C. (2005). [http://www.mendeley.com/research/casein-micelle-structure-concise-review/ Casein micelle structure: a concise review]. ''Songklanakarin Journal of Science and Technology'', 27(1), 201-212.
* Shelanski, M. L., Gaskin, F., & Cantor, C. R. (1973). [http://www.ncbi.nlm.nih.gov/pmc/articles/PMC433354/ Microtubule assembly in the absence of added nucleotides]. ''Proceedings of the National Academy of Sciences of the United States of America'', 70(3), 765-8.
* Silverman, B. W. (1986). [http://lccn.loc.gov/85021347 ''Density Estimation for Statistics and Data Analysis'']. Chapman and Hall: London.
* Thompson, M. P., Gordon, W. G., Boswell, R. T., & Farrell Jr., H. M. (1969). [http://dx.doi.org/10.3168/jds.S0022-0302(69)86719-6 Solubility solvation, and stabilization of α<sub>s1</sub>- and β-caseins]. ''Journal of Dairy Science'', 52(8), 1166-1173. doi: 10.3168/jds.S0022-0302(69)86719-6.


# Carter, NJ, & Cross, RA (2005). [http://www.nature.com/nature/journal/v435/n7040/abs/nature03528.html Mechanics of the kinesin step]. ''Nature'', 435(7040),308-12. doi: 10.1038/nature03528
* Vale, R. D., Reese, T., & Sheetz, M. (1985). [http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2851632/ Identification of a novel force generating protein, kinesin, involved in microtubule-based motility]. ''Cell'', 42(1), 39-50.  
# Vale, RD, & Fletterick, RJ(1997). [http://www.ncbi.nlm.nih.gov/pubmed/9442886 The design plan of kinesin motors]. ''Annual review of cell and developmental biology'', 13, 745-77. doi: 10.1146/annurev.cellbio.13.1.745.
# Hua, W, Young, E, Fleming, M, & Gelles, J (1997). [http://www.nature.com/nature/journal/v388/n6640/abs/388390a0.html Coupling of kinesin steps to ATP hydrolysis]. ''Nature'', 388, 390-393.
* Vale, R. D., & Fletterick, R. J. (1997). [http://dx.doi.org/10.1146/annurev.cellbio.13.1.745 The design plan of kinesin motors]. ''Annual review of cell and developmental biology'', 13, 745-77. doi: 10.1146/annurev.cellbio.13.1.745.
# Vale, R, Reese, T, & Sheetz, M (1985). [http://www.ncbi.nlm.nih.gov/pubmed/3926325 Identification of a novel force generating protein, kinesin, involved in microtubule-based motility]. ''Cell'', 42(1), 39-50. doi: 10.1016/j.bbi.2008.05.010.
# Goldstein, LSB, & Philp, AV (1999). [http://www.ncbi.nlm.nih.gov/pubmed/10611960 The road less traveled: emerging principles of kinesin motor utilization]. ''Annual review of cell and developmental biology'', 15, 141-183.
* Vater, W., Fritzsche, W., Schaper, Bohm, K. J., Unger, E., & Jovin, T. M. (1995). [http://www.ncbi.nlm.nih.gov/pubmed/7622594 Scanning force microscopy of microtubules and polymorphic tubulin assemblies in air and in liquid]. ''Journal of cell science'', 108 (Pt 3), 1063-9.
# Block, SM, Goldstein, LSB, & Schnapp, BJ (1990). [http://www.nature.com/nature/journal/v348/n6299/abs/348348a0.html Bead movement by single kinesin molecules studied with optical tweezers]. ''Nature'', 348, 348-352. doi: 10.1038/348348a0
# Yildiz, A, Tomishige, M, Vale, RD, & Selvin, PR (2004). [http://www.sciencemag.org/content/303/5658/676.abstract Kinesin walks hand-over-hand]. ''Science'' (New York, N.Y.), 303(5658), 676-8. doi: 10.1126/science.1093753.
* Verma, V., Hancock, W. O., & Catchmark, J. M. (2008). [http://dx.doi.org/10.1186/1754-1611-2-14 The role of casein in supporting the operation of surface bound kinesin]. ''Journal of biological engineering'', 2, 14. doi: 10.1186/1754-1611-2-14.
# Gelles, J, Schnapp, BJ, & Sheetz, MP (1988). [http://www.nature.com/nature/journal/v331/n6155/abs/331450a0.html Tracking kinesin-driven movements with nanometre scale precision]. ''Nature'', 331(6155), 450-3. doi: 10.1038/331450a0.
# Böhm, KJ, Steinmetzer, P, Daniel, A, Baum, M, Vater, W, & Unger, E (1997). [http://www.ncbi.nlm.nih.gov/pubmed/9227852 Kinesin-driven microtubule motility in the presence of alkaline-earth metal ions: indication for a calcium ion dependent motility]. ''Cell motility and the cytoskeleton'', 37(3), 226-31. doi: 10.1002/(SICI)1097-0169(1997)37:3<226::AID-CM4>3.0.CO;2-4.
* Walstra, P. (1999). [http://dx.doi.org/10.1016/S0958-6946(99)00059-X Casein sub-micelles: do they exist?]. ''International Dairy Journal'', 9(3-6), 189-192. doi: 10.1016/S0958-6946(99)00059-X.
# Böhm, KJ, Stracke, R, Baum, M, Zieren, M, & Unger, E (2000). [http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6T36-3YC64BM-1T&_user=1550512&_coverDate=01/21/2000&_rdoc=1&_fmt=high&_orig=search&_origin=search&_sort=d&_docanchor=&view=c&_searchStrId=1597513339&_rerunOrigin=google&_acct=C000053660&_version=1&_urlVersion=0&_userid=1550512&md5=ffe933ea5f6afec18cef70286027102e&searchtype=a Effect of temperature on kinesin driven microtubule gliding and kinesin ATPase activity]. ''FEBS letters'', 466(1), 59-62. doi: 10.1016/S0014-5793(99)01757-3.
# Böhm, KJ, Stracke, R, & Unger, E (2000). [http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6WCB-45FCFKG-27&_user=1550512&_coverDate=06/30/2000&_rdoc=1&_fmt=high&_orig=search&_origin=search&_sort=d&_docanchor=&view=c&_searchStrId=1597514459&_rerunOrigin=google&_acct=C000053660&_version=1&_urlVersion=0&_userid=1550512&md5=2276c2a905aa2e9cbab7ab375a026ede&searchtype=a Speeding up kinesin-driven microtubule gliding in vitro by variation of cofactor composition and physicochemical parameters]. ''Cell biology international'', 24(6), 335-41. doi: 10.1006/cbir.1999.0515.
# Ozeki, T, Verma, V, Uppalapati, M, Suzuki, Y, Nakamura, M, Catchmark, JM, et al. (2009). [http://www.ncbi.nlm.nih.gov/pubmed/19383474 Surface-bound casein modulates the adsorption and activity of kinesin on SiO2 surfaces]. ''Biophysical journal'', 96(8), 3305-18. doi: 10.1016/j.bpj.2008.12.3960.
# Woehlke, G, Ruby, AK, Hart, CL, Ly, B, Hom-Booher, N, & Vale, RD (1997). [http://www.ncbi.nlm.nih.gov/pubmed/9244295 Microtubule interaction site of the kinesin motor]. ''Cell'', 90(2), 207-16. doi: 10.1016/S0092-8674(00)80329-3.
# Moorjani, SG, Jia, L, Jackson, TN, & Hancock, WO (2003). [http://pubs.acs.org/doi/abs/10.1021/nl034001b Lithographically Patterned Channels Spatially Segregate Kinesin Motor Activity and Effectively Guide Microtubule Movements]. ''Nano Letters'', 3(5), 633-637. doi: 10.1021/nl034001b.
# Hess, H, Clemmens, J, Qin, D, Howard, J, & Vogel, V (2001). [http://pubs.acs.org/doi/abs/10.1021/nl015521e Light Controlled Molecular Shuttles Made from Motor Proteins Carrying Cargo on Engineered Surfaces]. ''Nano Letters'', 1(5), 235-239. doi: 10.1021/nl015521e.
# Ray, S, Meyhöfer, E, Milligan, RA, & Howard, J (1993). [http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2119687/ Kinesin follows the microtubule’s protofilament axis]. ''The Journal of Cell Biology'', 121(5), 1083-1093. doi: 10.1083/jcb.121.5.1083.
# Verma, V, Hancock, WO, & Catchmark, JM (2008). [http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2586618/ The role of casein in supporting the operation of surface bound kinesin]. ''Journal of biological engineering'', 2, 14. doi: 10.1186/1754-1611-2-14.
# Howard, J., Hudspeth, A. J., & Vale, R. D. (1989). [http://www.nature.com/nature/journal/v342/n6246/abs/342154a0.html Movement of microtubules by single kinesin molecules]. ''Nature'', 342(6246), 154-158. Nature Publishing Group. doi: 10.1038/342154a0. doi: 10.1007/BF00421079.
# Fiat, A.-M., & Jollès, P. (1989). [http://www.springerlink.com/content/v747128645058154/ Caseins of various origins and biologically active casein peptides and oligosaccharides: structural and physiological aspects]. ''Molecular and cellular biochemistry'', 87(1), 5-30.
# Fox, P, & McSweeney, P (1998). Chapter 4: Milk Proteins. [http://lccn.loc.gov/97077281 Dairy chemistry and biochemistry] (1st ed., pp. 146-238). London: Blackie Academic & Professional.
# Hancock, WO, & Howard, J (1998). [http://jcb.rupress.org/content/140/6/1395.abstract Processivity of the motor protein kinesin requires two heads]. ''The Journal of cell biology'', 140(6), 1395-405. doi: 10.1083/jcb.140.6.1395.
# Fox, P, & McSweeney, P (1998). Chapter 9: Heat-induced changes in milk. [http://lccn.loc.gov/97077281 Dairy chemistry and biochemistry] (1st ed., pp. 347-378). London: Blackie Academic & Professional.
# Zittle, C. a, & Walter, M. (1963). [http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B9887-502VBPJ-6&_user=1550512&_coverDate=11/30/1963&_rdoc=1&_fmt=high&_orig=gateway&_origin=gateway&_sort=d&_docanchor=&view=c&_searchStrId=1665163656&_rerunOrigin=google&_acct=C000053660&_version=1&_urlVersion=0&_userid=1550512&md5=b2d6cba416d84d09d77fe4dcb00f154b&searchtype=a Stabilization of β-Casein by κ-Casein Against Precipitation by Calcium Chloride]. ''Journal of Dairy Science'', 46(11), 1189-1191. doi: 10.3168/jds.S0022-0302(63)89243-7.
# Zittle, C. a. (1961). [http://www.journalofdairyscience.org/article/S0022-0302(61)90026-1/abstractref Stabilization of Calcium-Sensitive (α<sub>s</sub>) Casein by Kappa Casein: Effect of Chymotrypsin and Heat on Kappa-Casein]. ''Journal of Dairy Science'', 44(11), 2101-2103. doi: 10.3168/jds.S0022-0302(61)90026-1.
# Payensa, T. A. J., & Markwijka, B. W. V. (1963). [http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B73G9-4894JVF-7B&_user=1550512&_coverDate=12/31/1963&_rdoc=1&_fmt=high&_orig=gateway&_origin=gateway&_sort=d&_docanchor=&view=c&_searchStrId=1665169785&_rerunOrigin=google&_acct=C000053660&_version=1&_urlVersion=0&_userid=1550512&md5=8b4e60b4641086904eeded88db68a704&searchtype=a Some features of the association of β-casein]. ''Biochimica et Biophysica Acta'', 71, 517-530.
# O’Connell, J. E., Grinberg, V. Y., & Kruif, C. G. de. (2003). [http://www.ncbi.nlm.nih.gov/pubmed/12600768 Association behavior of β-casein]. ''Journal of Colloid and Interface Science'', 258(1), 33-39. doi: 10.1016/S0021-9797(02)00066-8.
# Leclerc, E., & Calmettes, P. (1997). [http://prl.aps.org/abstract/PRL/v78/i1/p150_1 Interactions in Micellar Solutions of β Casein]. ''Physical Review Letters'', 78(1), 150-153. doi: 10.1103/PhysRevLett.78.150.
# Thompson, M. P., Gordon, W. G., Boswell, R. T., & Farrell Jr., H. M. (1969). [http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B9887-500X2S4-4&_user=1550512&_coverDate=08/31/1969&_rdoc=1&_fmt=high&_orig=gateway&_origin=gateway&_sort=d&_docanchor=&view=c&_searchStrId=1665174111&_rerunOrigin=google&_acct=C000053660&_version=1&_urlVersion=0&_userid=1550512&md5=1af5974382392aaf41ca05b3f8d9cfe2&searchtype=a Solubility Solvation, and Stabilization of α<sub>s1</sub> - and β-Caseins]. ''Journal of Dairy Science'', 52(8), 1166-1173. doi: 10.3168/jds.S0022-0302(69)86719-6.
# Bingham, E. W. (1971). [http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B9887-5002772-K&_user=1550512&_coverDate=07/31/1971&_rdoc=1&_fmt=high&_orig=gateway&_origin=gateway&_sort=d&_docanchor=&view=c&_searchStrId=1665174584&_rerunOrigin=google&_acct=C000053660&_version=1&_urlVersion=0&_userid=1550512&md5=829d1513a09d63dfb58886fcf47ea7cd&searchtype=a Influence of Temperature and pH on the Solubility of α<sub>s1</sub>-, β- and κ-Casein]. ''Journal of Dairy Science'', 54(7), 1077-1080
# Asbury, CL, Fehr, AN, & Block, SM (2003). [http://www.sciencemag.org/content/302/5653/2130.abstract Kinesin moves by an asymmetric hand-over-hand mechanism]. ''Science'' (New York, N.Y.), 302(5653), 2130-4. doi: 10.1126/science.1092985.
# Berliner, E, Young, E, Anderson, K, Mahtani, H, & Gelles, J (1995). [http://www.nature.com/nature/journal/v373/n6516/abs/373718a0.html Failure of a single-headed kinesin to track parallel to microtubule protofilaments]. ''Letters to Nature'', 373(23), 718-721. doi:10.1038/373718a0.
# Shelanski, ML, Gaskin, F, & Cantor, CR (1973). [http://www.ncbi.nlm.nih.gov/pmc/articles/PMC433354/ Microtubule assembly in the absence of added nucleotides]. ''Proceedings of the National Academy of Sciences of the United States of America'', 70(3), 765-8.
# http://www.cellbio.duke.edu/kinesin/
# Silverman, BW (1986). [http://lccn.loc.gov/85021347 Density Estimation for Statistics and Data Analysis]. Chapman and Hall: London.
# Gagliano, J, Walb, M, Blaker, B, Macosko, JC, & Holzwarth, G. (2010). [http://www.springerlink.com/content/1h00885446369011/ Kinesin velocity increases with the number of motors pulling against viscoelastic drag]. ''European biophysics journal'': EBJ, 39(5), 801-13. doi: 10.1007/s00249-009-0560-8.
# Walstra, P (1999). [http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6T7C-3X52FPN-6&_user=1550512&_coverDate=03/31/1999&_rdoc=1&_fmt=high&_orig=gateway&_origin=gateway&_sort=d&_docanchor=&view=c&_searchStrId=1670581514&_rerunOrigin=google&_acct=C000053660&_version=1&_urlVersion=0&_userid=1550512&md5=181e593ea18480d552027426ccc74048&searchtype=a Casein sub-micelles: do they exist?]. ''International Dairy Journal'', 9(3-6), 189-192. doi: 10.1016/S0958-6946(99)00059-X.
# Phadungath, C (2005). [http://www.mendeley.com/research/casein-micelle-structure-concise-review/ Casein micelle structure: a concise review]. ''Songklanakarin Journal of Science and Technology'', 27(1), 201-212.
# Vater, W., Fritzsche, W., Schaper, a, Böhm, K. J., Unger, E., & Jovin, T. M. (1995). [http://www.ncbi.nlm.nih.gov/pubmed/7622594 Scanning force microscopy of microtubules and polymorphic tubulin assemblies in air and in liquid]. ''Journal of cell science'', 108 (Pt 3), 1063-9.
# Huang, Y, Uppalapati, M, Hancock, WO. & Jackson, TN (2005). [http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=1528638&tag=1 Microfabricated capped channels for biomolecular motor-based transport]. ''IEEE Transactions on Advanced Packaging'', 28(4), 564-570. doi: 10.1109/TADVP.2005.858330.


==[[/Notebook entries|Notebook entries]]==
* Yildiz, A., Tomishige, M., Vale, R. D., & Selvin, P. R. (2004). [http://dx.doi.org/10.1126/science.1093753 Kinesin walks hand-over-hand]. ''Science'' (New York, N.Y.), 303(5658), 676-8. doi: 10.1126/science.1093753.
* Zittle, C. A. (1961). [http://dx.doi.org/10.3168/jds.S0022-0302(61)90026-1 Stabilization of calcium-sensitive (α<sub>2</sub>) casein by kappa Casein: Effect of chymotrypsin and heat on kappa-casein]. ''Journal of Dairy Science'', 44(11), 2101-2103. doi: 10.3168/jds.S0022-0302(61)90026-1.
* Zittle, C. A, & Walter, M. (1963). [http://dx.doi.org/10.3168/jds.S0022-0302(63)89243-7 Stabilization of β-casein by κ-casein against precipitation by calcium chloride]. ''Journal of Dairy Science'', 46(11), 1189-1191. doi: 10.3168/jds.S0022-0302(63)89243-7.
<br style="clear:both;"/>


==[http://www.openwetware.org/wiki/User:Andy_Maloney/Surface_passivation_effects_on_kinesin_and_microtubules/Notebook_entries Notebook entries]==
All of my raw observations, raw data taking, and silly ramblings are contained in my notebook entries. They are the unedited versions of this page.
All of my raw observations, raw data taking, and silly ramblings are contained in my notebook entries. They are the unedited versions of this page.

Latest revision as of 13:48, 11 June 2011

Purpose

This page describes the experiment where I investigated gliding speed variations of microtubules using different surface passivation schemes using the gliding motility assay.

This is the second chapter in my completely open notebook science dissertation. If you would like to post questions, comments, or concerns, please join the wiki and post comments to the talk page. If you do not want to join the wiki and would still like to comment, feel free to email me.

A pdf version of the Introduction can be downloaded here. This is the final snapshot of the dissertation that has been approved by my committee. This file will inevitably become out of sync with the wiki pages.

A zip folder containing the LaTeX code can be down loaded here.

Note

This chapter ended up becoming an Open Access paper on PLoS ONE. You can view it on their website, comment if you like and you can cite it below,

Maloney A, Herskowitz LJ, & Koch SJ (2011) Effects of Surface Passivation on Gliding Motility Assays. PLoS ONE, 6(6): e19522. doi: 10.1371/journal.pone.0019522.

Acknowledgements

I would like to thank Dr. Haiqing Liu (while in the lab of Dr. Gabriel A. Montano) for supplying kinesin to our lab. I would also like to thank Dr. Susan Atlas and the support from DTRA CB Basic Research Program under Grant No. HDTRA1-09-1-008 and the UNM IGERT on Integrating Nanotechnology with Cell Biology and Neuroscience NSF Grant DGE-0549500. Finally, I'd like to thank Dr. Erik Schaeffer for his discussions on temperature stabilization.

Introduction

Figure 1: Image of our mascot "Kiney" at the microscope where I perform experiments. The plush doll form of Kiney was made by Child's Own Studios.

Both kinesin and microtubules are vital components of eukaryotic cells. Kinesin is used as a vehicle to shuttle items from one part of the cell to another and microtubules are the roads that kinesin travel on. Kinesin walks along microtubules in one direction and does so by converting chemical energy, in the form of ATP hydrolysis, to linear motion (Carter 2005, Vale 1997, Hua 1997, Vale 1985, Goldstein 1999). Biophysical observations of motility can be carried out in many different ways, however, the two most prominent observational techniques investigate kinesin and microtubules via the gliding motility assay or, with an optical trap (Block 1990, Yildiz 2004, Gelles 1988). The gliding motility assay (Bohm 1997, Bohm 2000a, Bohm 2000b) is the experimental procedure of interest for this study and a description on how to prepare a gliding motility assay can be found in Chapter 2.

This study aims to show that there are subtle differences in the speeds at which microtubules will glide at depending on the surface passivation used. It also shows that different surface passivations support different lengths of microtubules. This chapter will discuss the subtle differences to the gliding motility assay already outlined in Chapter 2. I will also discuss some of the technological hurdles that were accomplished in order to obtain stable speed data.

Methods and materials

In this section, I will discuss the technological hurdles required to obtain stable data and the subtle differences in the generic gliding motility assay described in Chapter 2.

Temperature stabilization

Figure 2: Graph showing three experiments using different passivation schemes. Note that each individual trace continuously increases in speed over time.

Temperature stabilization is crucial for observing stable speeds. Without it, I observed microtubule gliding speeds increase over time. Figure 2 shows data that did not use a temperature stabilized objective. The data show a sharp initial increase in speed which, over time would taper but never level off. There are three different assays in the graph, one each of: alpha casein, beta casein and whole casein. A description of the different types of caseins will be given below, briefly they are the constituents of whole casein described in Chapter 2. Using the data from Figure 2, I thought that I observed the goal of this study; which was to observe speed changes dependent on the type of passivation used. However, what I observed was that kinesin is a very sensitive temperature probe as I will discuss in more detail below.

I presented Figure 2 at the Biophysical Society Meeting 2010 where Stefan Diez suggested that the increase in speed over time was due to a temperature effect. I did not initially understand his comment because there was nothing attached to the microscope that could be heating the sample. So, I didn't really do anything about it. I presented more of the same data showing speed changes due to water isotopes and osmolytes at a conference in Santa Fe later that year (Maloney 2010). Dr. Erik Schaeffer of TU Dresden attended the conference and he again told me that there was a temperature issue with my data. He described to me the microscope setup used in his lab which stabilized the temperature of their objective with millikelvin precision. He told me that with this setup, he could tell rather precisely when and if a graduate student in his lab turned on the computer monitor near the microscope. This story blew me away and I of course didn't think it possible but, it most certainly is true as I found out with my experiments. If a computer monitor not even attached to the microscope could register a temperature increase on the objective, then there was a possibility that my microscope was heating up due to the mercury lamp.

Figure 3: Temperature of the microscope objective with no temperature stabilization and the mercury lamp on shining through the objective. The black curve is when the lamp was on and the red was when it was switched off. Figure 4: Temperature of the microscope objective with temperature stabilization. The initial spikes are due to turning the stabilization electronics on and off. The smaller spikes at later times are when a slide is removed from the objective and replaced with a new slide at room temperature.

The temperature of the entire microscope does increase over time due to having the mercury lamp on. Figure 3 shows the temperature of the objective due to having the mercury lamp on and shining through it. The temperature of the objective was taken at its top, near where the sample would be. No oil was used on the objective for this measurment. As can be clearly seen, the objective does reach a stable temperature, albeit 5.5 hours after turning the lamp on. This is not ideal for experiments as one would have to wait 5.5 hours before being able to take measurements. This graph does not show the effect of placing a microscope slide at room temperature on the objective as doing so causes the objective temperature to decrease, as can be seen in Figure 4.

Figure 5: Graph showing speed values of data from Figure 2 after plotting against the absolute time they were observed. Figure 6: Graph showing speed values after temperature stabilization.

Re-plotting the data taken in Figure 2 against absolute time, i.e. from the seconds measured since 1904, shows a different story about microtubule speed measurements and casein passivation than is shown. Thankfully I took all the data in Figure 2 on the same day and when plotted with their time stamps appropriately zeroed from the first image taken, Figure 5, one can clearly see that there is an overall increase in speed as time goes on. One can also see that over the time the slide is on the objective, the microtubule speeds increase. This was due to the fact that the slides were at room temperature and they heated up when on the objective. A plot showing the effect of temperature on the objective for turning the heating element on and off, and adding oil and removing and replacing a slide on the objective can be seen in Figure 4.

This finding I felt was unfortunate because it basically said that the large differences in gliding speeds was solely due to temperature effects and not due to the chemistry of passivation. Nonetheless, I took this opportunity to build a similar system to what Dr. Schaeffer uses in his lab to stabilize the temperature of my microscope objective (Mahamdeh 2009). As can be seen in Figure 4, with a stable temperature, speed measurements can be recorded with as little as ±4 nm/s errors. This is a feat all to itself since average speeds in the literature can quote errors as large as 50 --- 100 nm/s (Bohm 1997). Figure 4 also shows the large increase in speed observed in my earlier experiments for early times, except now, the data levels off. Figure 4 shows quite nicely that without temperature stabilization, speed measurements would not be stable. Figure 7 shows a movie when there was no temperature stabilization on the objective. The movie shows how the focus would drift which required constant adjustments. The movie loses focus when the overall image gets brighter. This is due to the objective collecting more light from the fluorescent microtubules in solution and not at the surface of the slide where the kinesin is adhered to.

<html><object width="300" height="300"><param name="movie" value="http://www.youtube.com/v/vq3z-TaDcuI?fs=1&amp;hl=en_US"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="http://www.youtube.com/v/vq3z-TaDcuI?fs=1&amp;hl=en_US" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="300" height="300"></embed></object></html>
Figure 7: Click here to view the movie via YouTube. Movie showing the focus drift due to temperature instabilities. When the overall image becomes brighter, the focus is drifting.

A detailed description of the objective heater build can be found in a post done on the website Instructables. Briefly, the objective heater is a PID control circuit using a software interface from TeTech. The control circuitry is connected to two 15 kΩ thermistors. One thermistor controls the heating element and the other is used to measure the objective temperature which is recorded by the software. The heating element used was a Kapton flexible heating element. This design can maintain a temperature to ±0.1°C. There are very few studies that indicate whether or not observation of the gliding motility assay was done with temperature stabilization. It has been shown that temperature does play a crucial role in obtaining stable data (Bohm 2000a, Bohm 2000b) in a few studies, as well as, the ones I have done.

Materials

I like to think of the preparation for all the solutions used in an assay as my mise en place. And, just like no one would ever touch a fellow cook's mise en place in a restaurant, no one but me was allowed to use my solutions. These rules were set in place partly due to how finicky these assays are and how I've learned that keeping a tight control on my solutions allows me to quickly replace chemicals when an assay has gone awry.

I have already spoken about several of the necessary tools used for this assay in Chapter 2. Below, I will link to the tools that do not change and go into greater detail about those that do. The items in the list that do not have links, will be described below.


Passivation solutions

This experiment used the different bovine casein constituents to investigate speed variations of microtubules in the gliding motility assay. In the temperature stabilization section of this chapter, my initial experiments saw huge differences in speeds using different caseins. As was already mentioned above, the large speed variations were due to temperature effects and not due to the passivation chemicals. Once I stabilized the temperature of my objective, I continued to investigate if there were any variations in speed due to surface passivation. It turns out that there was a difference in speed measurements due to surface passivation, albeit a more subtle difference than what I saw initially without temperature stabilization. To begin this experiment, I purchased the following caseins all from bovine milk.

Each casein component was reconstituted in PEM under constant stirring. I will outline below the different solutions that were prepared for this experiment giving the naming convention for each solution in the subheading.

W-PEM

For a detailed description of how to make W-PEM, please see Chapter 2.

α-PEM

The subscript s attached to the alpha casein means sensitive since the alpha caseins are the first caseins to be removed from solution by adding over 4 mM calcium. αs1-casein comprises approximately 37% of whole bovine casein while αs2-casein comprises only 10% (Fox 1998a). A mixture of the αs1- and αs2-caseins was purchased from Sigma.

Alpha PEM has 1.0 mg/mL α-casein in PEM. Dissolving α-casein in PEM required approximately 60-80 minutes of constant stirring at room temperature. The procedure I followed to make α-PEM is as follows.

  1. Weigh out 25 mg of α-casein.
  2. Add the 25 mg of α-casein to 25 mL of PEM.
  3. Stir for approximately 60-80 minutes or until there are no longer visible precipitates in solution.
  4. Allow the foam to settle if any.
  5. Aliquot into convenient screw top vials.

α-PEM will last for 6 months stored at 4°C. No additional filtering was done on the α-PEM solution.

β-PEM

β-casein comprises approximately 35% of the protein in whole bovine casein. It takes approximately 400 mM calcium to remove it from a solution of skim milk (Fox 1998a).

β-PEM has 1.0 mg/mL β-casein in PEM. The procedure for making β-PEM is very similar to how I made α-PEM except for the length of time required to mix.

  1. Weigh out 25 mg of β-casein.
  2. Add the 25 mg of β-casein to 25 mL of PEM.
  3. Stir for approximately 30-40 minutes or until there are no longer visible precipitates in solution.
  4. Allow the foam to settle if any.
  5. Aliquot into convenient screw top vials.

β-PEM will last for 6 months stored at 4°C. No additional filtering was done on the β-PEM solution.

κ-PEM

κ-casein is structurally very different from α and β casein. Kappa casein is a glycoprotein and was depicted in Chapter 2's figure of a casein micelle as the hairs. Kappa casein is thought to stabilize the casein micelle and it is unaffected by calcium concentration. It can even help to stabilize alpha and beta caseins from calcium precipitation (Fox 1998a).

κ-PEM has 1.0 mg/mL κ-casein in PEM. The procedure for making κ-PEM is very similar to how α-PEM is made, except for the length of time required to mix.

  1. Weigh out 25 mg of κ-casein.
  2. Add the 25 mg of κ-casein to 25 mL of PEM.
  3. Stir for approximately 15-20 minutes or until there are no longer visible precipitates in solution.
  4. Allow the foam to settle if any.
  5. Aliquot into convenient screw top vials.

κ-PEM will last for 6 months stored at 4°C. No additional filtering was done on the κ-PEM solution.

M-PEM

From the stated amounts of the individual casein components, I mixed a whole casein type solution using α-PEM, β-PEM, and κ-PEM which I called M-PEM. I decided to do this because I wanted to see if I could artificially reproduce the results obtained from W-PEM which used the purchased whole bovine casein.

Since all the components of casein were already in solutions of PEM, I just mixed them in a vial to obtain M-PEM.

  • 49% α-casein or 980 μL of α-PEM.
  • 37% β-casein or 740 μL of β-PEM.
  • 14% κ-casein or 280 μL of κ-PEM.

M-PEM will last for 6 months stored at 4°C. No additional filtering was done on the M-PEM solution.

I did not investigate the solubility of the caseins in a solution of PEM. Casein solubility is a complicated function of other casein constituents in solution (Zittle 1961, Zittle 1963), temperature (Payens 1963, O'Connell 2003, Leclerc 1997), genetic variants (Thompson 1969), ionic strength and types of salts in solution (Thompson 1969), calcium ion concentration (Zittle 1961, Zittle 1963, Thompson 1969), and pH (Bingham 1971).

Experiment and data analysis

The speed at which microtubules glide at in the motility assay depends on a number of factors. One of those factors is the pH of the solution. In my PEM solution, the amount of NaOH is approximate since each solution of PEM is pH-ed to 6.89. Bohm (Bohm 2000b) shows that gliding speed is affected by both the pH and the ionic strength of the solution the motors are in. In an effort to reduce as many variables as possible for speed measurements, I chose to maintain the pH of the PEM buffers at exactly 6.89 and vary the amount of NaOH necessary to achieve this pH.

For a complete description of the gliding motility assay, please see Chapter 2. Briefly, polymerization was carried out in a Thermo PCR Sprint thermocycler held constant at 37°C and incubated for 30 minutes using 1 μL of the 29% rhodamine-labeled and 71% unlabeled tubulin. After 30 minutes, the microtubules were fixed and diluted by 200x by adding 199 μL of PEM-T. Polymerized microtubules were stored at room temperature and protected from ambient light until used in a motility assay. Storing polymerized microtubules at 4°C will cause rapid depolymerization (Shelanski 1973).

Gliding motility assay

Experiments followed the same recipe outlined in Chapter 2. The steps taken for this experiment were as follows.

  1. Prepared a flow cell.
  2. Incubated the flow cell with 1.0 mg/mL of the various caseins in PEM for 10 minutes.
  3. During the 10 minute incubation, kinesin was diluted in 0.5 mg/mL of the same casein in PEM used in Step 2, plus 1 mM ATP. The final concentration of kinesin used in these experiments was 27.5 μg/mL.
  4. After 10 minutes, kinesin was flowed into the flow cell by fluid exchange. This was then allowed to sit for 5 minutes.
  5. During the various incubation steps, a new motility solution was prepared for each assay. The motility assays consisted of:
  6. After the 5 minute incubation with kinesin, the motility solution was introduced to the flow cell by fluid exchange.
  7. The flow cell was then sealed with nail polish.

In order to not dilute the Taxol used to stabilize microtubules, it is added in the motility solution at the same concentration used in PEM-T. Preventing dilution of chemicals is why 1 mM ATP is added to the motility solution as well. The kinesin home page and Verma et al. (Kinesin home page, Verma 2008), suggest that adding casein to the motility solution enhances the chances of a gliding motility assay to work properly. I observed that adding casein to the motility solution causes microtubules to undergo non ideal motility, i.e. they move in tight circles and end up wrapping around themselves such that the microtubules look like squiggles and are untrackable. In order to prevent such behavior, I did not include casein in the motility solution.

After sealing the flow cell, the slide was immediately placed on the microscope for observation. Data was taken at 5 frames per second with a single exposure time for each frame of 100 ms. The camera software (KochLab) was set to take a total of 600 images for one region of interest (ROI) and had an EMCCD gain of 150. The time to capture 600 frames was approximately 2 minutes of total exposure for one ROI. After the camera had captured 600 frames, I moved the sample on the microscope. I did this because I wanted to get a broad sample of speed measurements from the flow cell. Kinesin may not be distributed uniformly on the surface of the flow cel and may give different speed measurements dependent on where the observation took place. Hunt et al. (Hunt 1994) showed that microtubules would slow down against viscous loads if the kinesin concentration was low. My assays never used small concentrations of kinesin but, to ensure that I had a sampling of speed that did not have to take into account kinesin coverage, I moved the sample around. Each slide was repositioned on the microscope for a total of 15 times giving me 15 ROIs to analyze data from.

Data analysis

Microtubules were then tracked using a custom LabVIEW tracking application written by Larry Herskowitz (KochLab). The tracking software (KochLab) used image segmentation algorithms to identify microtubule ends via pattern matching. Microtubules successfully tracked for fewer than 100 consective images were discarded. This lower bound of images was found through experiment to give reliable data. Microtubules that could be tracked with fewer images did not consistently give high fidelity data and thus a lower bound for images was set. The software was unable to track microtubules that had a segmented area less than 55 pixels due to the pattern matching algorithms used. This put a lower bound on the length of trackable microtubules to be around 2 μm. Finally, tracking of microtubules stopped if the microtubule crossed other microtubules or if it came too close to the edges of the field of view.

Once tracking was complete, the X and Y pixel values for the ends of microtubules were analyzed with another custom LabVIEW analysis program written by Larry Herskowitz and Steve Koch (KochLab). This program calculated the speeds at which microtubules were moving at by subtracting the pixel values of consecutive tracked microtubule images and dividing by the time between frames.

[math]\displaystyle{ s=166.7\left(\frac{nm}{s}\right)\times\frac{\sqrt{(x_{n+1}-x_n)^2+(y_{n+1}-y_n)^2}}{t_{n+1}-t_n} }[/math]

These values are plotted in Figure 8 as the blue markers. As one can see, there is a lot of noise in these raw measurements. I believe that the cause is because microtubule ends are never permanently attached to the kinesin surface and thus undergo Brownian motion transverse to the motility direction. To alleviate this noise, a sliding Gaussian window of 2 seconds was used to smooth the data. This newly smoothed data is depicted as the black curve in Figure 8. Boundary effects due to the finite sample size are quite evident in the graph. There are a lot of techniques that try to compensate for these edge effects, however, we as a group decided to not take them into consideration. Instead, we decided to remove 5 seconds worth of points from the beginning and end of the data set. This completely removed all the edge effects due to smoothing.

Figure 8: Data analysis. Blue markers are the speed values from unsmoothed X and Y positions of the microtubule end. The black curve shows the speed values calculated after smoothing the position data using a Gaussian window with a width of 2 seconds. The red curve shows the speed data after removing the first and last 5 second time periods and is the data that is then analyzed by the KDE algorithm.
Figure 9: KDE of a single microtubule gliding speed using alpha casein passivation.

Kernel density estimation (KDE) (Silverman 1986) was then done on all the individual microtubules. Making a KDE is very similar to making a histogram of the speed data. Except that the KDE method applies a Gaussian kernel around every point instead of placing a data point in a bin. The Gaussians are then summed together to give a smooth representation of what the most likely microtubule speed is. Figure 9 shows the KDE of the microtubule data in Figure 8. The bandwidth used in this kernel was 20 nm/s. As you can see in Figure 8, The smoothed red line data is not completely flat. This is because the microtubule does not travel at the same speed all the time. It can pause, stop completely, or even slow down. Using the KDE method allows one to see these subtle differences in speeds and is quite evident in Figure 9.

Speed versus time data for all the microtubules in an individual region of interest (ROI) were then concatenated together (all the smoothed data similar to Figure 8) and the most likely speed for a ROI was extracted using the KDE method with a Gaussian kernel of width 50 nm/s. Using the KDE method instead of a simple mean reduces the sensitivity to microtubule pausing or stalling, which was evident in many assays. We used a large kernel width to reduce sensitivity to possible speed changes due to number of kinesin motors or other causes (Gagliano 2010). The most likely speeds for individual regions were then plotted versus time to determine when the slide had reached thermal equilibrium with the objective, see Figure 6. The initial 5 data points were removed for all data sets indicating that it took about 10 minutes for the slide to reach a stable temperature. Each assay; alpha, beta, kappa, whole, and mixed casein was repeated 3 separate times on different days and with different kinesin aliquots. When possible, the mean and standard error of the mean was computed for the three data points for a given assay time.

Results and discussion

Results

Data was taken at 33.1 ± 0.1°C as measured from the top thermistor on the objective. This temperature is well above the temperature the objective would reach due to long-term heating, see Figure 3, from the Hg lamp and was found to give consistent data, Figure 6. I observed that the closer the ROI was to the boundaries of the flow cell, the slower the microtubule gliding speed was. I also observed that the propensity for depolymerization increased near the boundaries of the flow cell. In order to obtain consistent data and prevent depolymerization of the microtubules, gliding assays were observed in the center of the flow cell channel, except where otherwise noted. All images have had dead pixels removed by an interpolation function and have been false colored using ImageJ's green fire blue LUT using a custom LabVIEW 7.1 application written by Larry Herskowitz (KochLab).

Bovine alpha casein (a mixture of αs1, 37% and αs1, 10%) constitutes approximately 47% of whole bovine casein (Fox 1998a). This passivation was capable of supporting small microtubules and longer ones as can be seen in Figure 10 & 11. When using alpha casein, the gliding motility assay worked every time except when the kinesin or antifade system lost its effectiveness for maintaining a gliding assay.

<html><object width="300" height="300"><param name="movie" value="http://www.youtube.com/v/UnRTr1FUdtY?fs=1&amp;hl=en_US"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="http://www.youtube.com/v/UnRTr1FUdtY?fs=1&amp;hl=en_US" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="300" height="300"></embed></object></html>
Figure 10: Typical image from a gliding motility assay using alpha casein as the surface passivator. Figure 11: Typical movie from a gliding motility assay using alpha casein as the surface passivator.

Bovine beta casein comprises approximately 35% of whole casein and visible precipitates took less time to dissolve in PEM as compared to alpha casein. Figure 12 & 13 shows that beta casein as a surface passivator was not ideal. It did not support smaller microtubules and did not in general have very many motile microtubules in any assay. The microtubules that were motile, were typically quite long. Beta casein also caused the microtubule's minus and positive ends to detach from the kinesin surface while undergoing motility more often than the other passivation schemes. This caused errors in the tracking and thus did not give consistent data. This is unfortunate as it can be purified to better than 98% making this component of whole casein the purest commercially available. Another interesting phenomenon observed when using beta casein was that motile microtubules were not found in the center of the channel for the flow cell. Motile microtubules were observed, but they were always found off center to the flow cell channel. I am not sure of the reason for this but, it may depend on kinesin or casein concentration. I did not vary the input kinesin or casein concentration for these studies.

<html><object width="300" height="300"><param name="movie" value="http://www.youtube.com/v/6IXpaC_mqZk?fs=1&amp;hl=en_US"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="http://www.youtube.com/v/6IXpaC_mqZk?fs=1&amp;hl=en_US" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="300" height="300"></embed></object></html>
Figure 12: Typical image from a gliding motility assay using beta casein as the surface passivator. Figure 13: Typical movie from a gliding motility assay using beta casein as the surface passivator.

Kappa casein, compared to alpha and beta, is structurally very different. It is a glycoprotein and is thought to stabilize the casein micelle (Fox 1998a, Walstra 1999, Phadungath 2005) by sterically hindering the aggregation of too many casein sub-micelles. It did not support motility in a very consistent manner as can be seen from Figure 14 & 15. As was the case for beta casein, kappa casein did not support motility in the center of the channel of the flow cell. Stuck microtubules were found near the center of the flow cell and near the tape. However, between the boundaries of the flow cells and away from the center of it, there was motility. In the areas that motility existed, kappa casein was able to support motility of long and short microtubules with the exception of extremely short microtubules found to move only in the alpha or whole casein assays. The very short microtubules either remained stuck to the surface or exhibited motility for a very short period of time before going into solution. Kappa casein did a remarkable job of adhering microtubules to the slide much like how poly-L-lysine is used to fix microtubules on a slide (Vater 1995).

<html><object width="300" height="300"><param name="movie" value="http://www.youtube.com/v/s6cATn48z3Y?fs=1&amp;hl=en_US"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="http://www.youtube.com/v/s6cATn48z3Y?fs=1&amp;hl=en_US" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="300" height="300"></embed></object></html>
Figure 14: Typical image from a gliding motility assay using kappa casein as the surface passivator. Figure 15: Typical movie from a gliding motility assay using kappa casein as the surface passivator.

Whole bovine casein is the passivator of choice when doing gliding motility experiments. Whole bovine casein worked remarkably well for sustaining motility, Figure 15 & 17. Similar to the alpha casein passivation, whole casein worked every single time and gave consistent data. It was only when we deemed either the kinesin or the antifade system to have lost its effectiveness at maintaining microtubule gliding that the assay did not work. Of the 5 types of bovine casein solutions tested, whole casein required heat in order for visible precipitate to completely dissolve into a solution of PEM. I did not observe any adverse affects to motility by heating whole casein.

<html><object width="300" height="300"><param name="movie" value="http://www.youtube.com/v/LV9ELcgZT6I?fs=1&amp;hl=en_US"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="http://www.youtube.com/v/LV9ELcgZT6I?fs=1&amp;hl=en_US" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="300" height="300"></embed></object></html>
Figure 16: Typical image from a gliding motility assay using whole casein as the surface passivator. Figure 17: Typical movie from a gliding motility assay using whole casein as the surface passivator.

Mixing whole casein from the individual constituents of alpha, beta, and kappa was also used as a surface passivator. The mixed whole casein consisted of 49% alpha casein, 37% beta casein and, 14% kappa casein which is very similar to what Fox and McSweeney state as the casein components of bovine milk (Fox 1998a). Mixing it was easy since each component was already in a PEM solution. The behavior of the mixed bovine whole casein was indistinguishable from the purchased whole casein or the alpha casein passivation, Figure 18 & 19.

<html><object width="300" height="300"><param name="movie" value="http://www.youtube.com/v/C6CjWUu1E0k?fs=1&amp;hl=en_US"></param><param name="allowFullScreen" value="true"></param><param name="allowscriptaccess" value="always"></param><embed src="http://www.youtube.com/v/C6CjWUu1E0k?fs=1&amp;hl=en_US" type="application/x-shockwave-flash" allowscriptaccess="always" allowfullscreen="true" width="300" height="300"></embed></object></html>
Figure 18: Typical image from a gliding motility assay using mixed casein as the surface passivator. Figure 19: Typical movie from a gliding motility assay using mixed casein as the surface passivator.

Figure 20 shows the mean speed measurements for 15 different regions of interest for the alpha, beta, whole and mixed casein assays. Each region of interest is the mean and SEM from three separate samples. The passivator that gave the most consistent speed was alpha casein. The mean speed and SEM from our alpha casein measurement was 949 ± 4 nm/s. Purchased whole casein and mixed casein performed remarkably similarly and displayed average speed values of 966 ± 7 nm/s and 966 ± 6 nm/s respectively. Bovine beta casein performed poorly in comparison to alpha, whole, or mixed caseins and we measured the mean speed to be 870 ± 30 nm/s.

Figure 21 shows the observed speeds for kappa casein passivation. Since there were so many areas where no motility was observed in this assay, it was difficult to determine a mean speed measurement for each ROI as was done in Figure 20. However, it does appear that when motile, the speeds were around 870-880 nm/s with kappa casein as the surface passivator. This was similar to how beta casein performed.

Figure 20: Black circles are alpha casein passivation, red squares are beta casein passivation, green right side up triangles are whole casein passivation, and blue down pointing triangles are mixed casein passivation. Each data point is the mean for three ROIs from separate samples at the corresponding assay time point. Error bars are the SEM of those three measurements. Alpha casein had the most consistent average speed measurements at 949 ± 4 nm/s. Whole casein and mixed casein averaged to 966 ± 7 nm/s and 966 ± 6 nm/s respectively. Beta casein averaged to ± 30 nm/s. Figure 21: Green squares, red circles, and blue triangles represent 3 different assays. As the figure shows, kappa casein is not an ideal surface passivator. There are many regions in the flow cell where no motility exists at all and other areas where motility can give quasi consistent results. Albeit at much slower speeds than is reported from alpha, whole or mixed casein passivations. The open black circles show a characteristic alpha casein assay for comparison. Note that the initial increase in speed is due to the slide coming to thermal equilibrium with the objective.
Figure 22: Filled blue bars are length calculations for the alpha casein passivation, filled green bars are for the beta casein passivation, filled red bars are for the kappa casein passivation, unfilled black bars are for the mixed casein passivation, and unfilled purple bars are for the whole casein passivation. Length measurements were performed only on tracked microtubules and are estimations from computing the Convex Hull perimeter on eroded images of microtubules.

Figure 22 shows a histogram of microtubule lengths. To obtain lengths, an erosion algorithm was used on binary images of only the microtubules that were tracked. The erosion algorithm comes as a standard function in LabVIEW 7.1. The skeleton algorithm, as it is called in LabVIEW, is not optimized for measuring microtubule lengths and tended to overestimate them. Because of this, another algorithm was used on the skeletonized microtubules, namely a Convex Hull perimeter calculation, also found in the LabVIEW library of functions. Dividing the Convex Hull perimeter by 2 gave lengths that consistently fell in between manual measurements done by myself and Koch. As can be seen in the figure, alpha casein (filled blue bars), whole casein (empty purple line bars) and mixed casein (empty black line bars) all were able to sustain motility with smaller microtubules 2 --- 6 μm range. Beta casein (filled green bars) had significantly fewer microtubules that were tracked, however, those that were tended to be longer than the ones tracked in the alpha casein assay. Kappa casein (filled red bars) had many more trackable microtubules than beta casein but significantly fewer than alpha casein. The smallest trackable microtubules using our image segmentation algorithm are around 2 μm. Figure 22 shows that there are relatively few 2 μm microtubules in any of the assays. Kappa casein, however, had no microtubules that fell in the 2 --- 3 μm range but it had a large number of microtubules that were in the 20 --- 21 μm range. Length measurements using this method are not optimized for precision. This method does give a way to see the relative size distribution differences in the assays.

Discussion

It would appear that the more difficult it was to dissolve casein, the better it worked as a surface passivator. This may be a coincidence, or it may relate to the manner in which casein adsorbs to the glass. Whole casein was by far the most difficult to dissolve visible precipitate into PEM without heating. Alpha casein came in second, beta third and kappa fourth in terms of the time to dissolve completely in PEM at room temperature. Whole casein is approximately 50% alpha casein and seeing how well alpha casein performed as a surface passivator, it was not surprising to find that whole casein also performed well. The differences in measured speeds between alpha and whole casein could be a result of how kinesin is supported by the different caseins, or it could be due to differences in surface-coverage for passivation by the casein. It has been shown that using substrates of differing hydrophilicity with whole casein passivation affects the activity of kinesin (Huang 2005).

Purchased whole and mixed casein were practically indistinguishable. They performed almost identically and had the same measured speeds. Mixed whole casein has an upper bound of 20% impurities in it. This amount is very similar to the amount of impurities alpha casein has in it yet, mixed whole casein performed exactly how purchased whole casein did. This similarity between mixed and purchased whole casein suggests that the speed difference between alpha and whole casein is not due to impurities but rather that it is due to how kinesin is supported by the casein micelles or, how casein interacts with the glass. To elucidate this effect, it would be prudent to measure the speeds for the various caseins as a function of casein and kinesin concentrations during incubation. I have not performed these experiments.

Beta casein would have been the most ideal protein to use as the surface passivator since it can be purified to greater than 98% purity. Higher protein purity is advantageous for systematically producing devices that use kinesin and microtubules as sensors. However, beta casein did not perform very well. It had the least number of motile microtubules to track, it was not very reliable, and had a large distribution in speeds. It is possible, though, that varying other parameters such as kinesin concentration, or beta casein concentration could restore reliable motility. Again, these are future experiments.

Kappa casein would be an attractive surface passivator just for its ease in dissolving in PEM. However, where motility exists in the flow cell is not consistent and it never occurs in the center of the channel where I have observed the most consistent speed measurements from other assays. With kappa casein, many long and stable microtubules permanently stuck to the surface. I am not sure if the sticking is caused from kinesin attaching to microtubules and then somehow being impeded from moving or, if there is actually no kinesin on the kappa casein surface and the microtubules are just attracted to the kappa casein or glass.

Of the five types of bovine caseins used to observe the gliding motility assay, alpha casein performed very well. It is the easiest of the three commercially available bovine casein constituents to dissolve in PEM and can be purchased at 70% purity. Most likely, the 30% contaminants are from other casein components. It performed well every time an assay was prepared and worked just as well as mixed and purchased whole casein.

Conclusion

There are a wide variety of surface passivation strategies in the literature. This study showed that there are differences in how the gliding motility assay is observed dependent on the type of passivaiton used. Bovine alpha casein was the most reliable passivator when following the most typical gliding assay protocol found in [http://www.openwetware.org/wiki/User:Andy_Maloney/Kinesin_%26_Microtubule_Page Chapter 2. This is why I have chosen to use it for my following studies using isotopes of water in the gliding motility assay.

Future work

There are a great number of experiments that could be done to further this line of research. For instance, varying the amount of kinesin used in each assay could illuminate more characteristics of how kinesin interacts with the surface passivation. Also, varying the casein constituent concentration used to passivate the surface could bring to light the possibility that either beta or kappa casein is a better surface passivator than alpha casein. And finally, since the individual constituents of bovine casein can be purchased separately, one can devise experiments that uses engineered whole casein as the surface passivation. One could even use dephosphorylated alpha or beta casein as components to the engineered surface passivation.

Return to the table of contents.

Forward to Chapter 3.

References

  • Fox, P., & McSweeney, P. (1998). Chapter 9: Heat-induced changes in milk. Dairy Chemistry and Biochemistry (1st ed., pp. 347-378). London: Blackie Academic & Professional.
  • O'Connell, J. E., Grinberg, V. Y., & de Kruif, C. G. (2003). Association behavior of β-casein. Journal of Colloid and Interface Science, 258(1), 33-39. doi: 10.1016/S0021-9797(02)00066-8.
  • Vale, R. D., & Fletterick, R. J. (1997). The design plan of kinesin motors. Annual review of cell and developmental biology, 13, 745-77. doi: 10.1146/annurev.cellbio.13.1.745.
  • Yildiz, A., Tomishige, M., Vale, R. D., & Selvin, P. R. (2004). Kinesin walks hand-over-hand. Science (New York, N.Y.), 303(5658), 676-8. doi: 10.1126/science.1093753.


Notebook entries

All of my raw observations, raw data taking, and silly ramblings are contained in my notebook entries. They are the unedited versions of this page.