User:Allison K. Alix/Notebook/Thesis Research/2013/06/26

From OpenWetWare

(Difference between revisions)
Jump to: navigation, search
(13.7nm AuNP synthesis)
(13.7nm AuNP synthesis)
Line 16: Line 16:
* The nanoparticles produced from this reaction will be used in the silica coating procedure in the future. We are interested in finding a procedure for synthesizing AuNP that has a low diameter variation. The current procedure has a wide range (5-40nm) that greatly affects the amount of PVP/TES that need to be added for the silica coating procedure. Minimizing changes in variables will help simplify the procedure.
* The nanoparticles produced from this reaction will be used in the silica coating procedure in the future. We are interested in finding a procedure for synthesizing AuNP that has a low diameter variation. The current procedure has a wide range (5-40nm) that greatly affects the amount of PVP/TES that need to be added for the silica coating procedure. Minimizing changes in variables will help simplify the procedure.
-
1) Add 1mL 0.25mM HAuCl<sub>4</sub> to 100mL water
+
1) Add 1mL 0.25mM HAuCl<sub>4</sub> to 100mL water. Stir and heat to boiling.
 +
 
 +
Current [HAuCl<sub>4</sub>] = 1mM
 +
 
 +
1mM(x) = (0.25mM)(1mL)
 +
 
 +
x = 250μL 1mM HAuCl<sub>4</sub> in 750μL H<sub>2</sub>O
 +
 
 +
 
 +
 
 +
 
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->

Revision as of 21:55, 26 June 2013

Project name Main project page
Previous entry      Next entry

Preparation of DNA/MB Samples for FCS

Prepare the following samples:

1) 100pM DNA

13.7nm AuNP synthesis

  • The nanoparticles produced from this reaction will be used in the silica coating procedure in the future. We are interested in finding a procedure for synthesizing AuNP that has a low diameter variation. The current procedure has a wide range (5-40nm) that greatly affects the amount of PVP/TES that need to be added for the silica coating procedure. Minimizing changes in variables will help simplify the procedure.

1) Add 1mL 0.25mM HAuCl4 to 100mL water. Stir and heat to boiling.

Current [HAuCl4] = 1mM

1mM(x) = (0.25mM)(1mL)

x = 250μL 1mM HAuCl4 in 750μL H2O