| '''NOTE: IN PROGRESS!!'''
| | [[Sauer:ClpX purification/Protocol 1|Non-His<sub>6</sub>-tagged purification, Protocol 1]] |
| ==Protocol 1==
| |
| *This protocol has worked successfully for Jon and [[user:kathmc|Kathleen]]
| |
| | |
| ===Cell growth===
| |
| ClpX can be expressed in a variety of cell types, but greater success usually results from strains that do not have "leaky" expression. Tight control of expression can usually be obtained with a BL21 pLysS system, but others work as well. | |
| | |
| 1. Grow cells to a high density (~A<sub>600</sub>=1.0) at 37 ˚C in either LB or TB media. Then, shift temperature to 25 ˚C. Shortly thereafter, induce ClpX with 0.5–1 mM IPTG for 3 hr.
| |
| | |
| 2. Harvest cells by centrifugation. Resuspend in 1 mL lysis buffer (see buffer recipes below) per gram of wet cell pellet. The paste can be stored at -80 ˚C until you are ready to purify ClpX.
| |
| | |
| ===Lysis/ammonium sulfate((NH<sub>4</sub>)<sub>2</sub>SO<sub>4</sub>) precipitation===
| |
| 1. Thaw cells and add 10 mL lysis buffer per gram of cell pellet. Disrupt cells by either French press or gentle sonication.
| |
| | |
| 2. Spin at 13–15K rpm in Sorvall RC5B centrifuge with SA600 rotor for 1 hr to pellet large cell debris.
| |
| | |
| 3. Transfer supernatent to appropriate tubes and spin in ultracentrafuge (Baker lab) in Beckman Ti45 rotor for 1 hr at 40K rpm.
| |
| | |
| 4. Remove the supernatent to new tubes. Add (NH<sub>4</sub>)<sub>2</sub>SO<sub>4</sub> to 35% and stir at 4 ˚C for 1 hr–overnight.
| |
| | |
| 5. Spin at slow speed (4K in Beckman J6-HC swinging bucket rotor) to pellet (NH<sub>4</sub>)<sub>2</sub>SO<sub>4</sub> precipitate. If you spin too fast here, resuspension is more difficult.
| |
| | |
| 6. Just in case, take supernatent and add NH<sub>4</sub>SO<sub>4</sub> to 45% and stir at 4 ˚C. Spin as in step 5.
| |
| | |
| 7. Resuspend the (NH<sub>4</sub>)<sub>2</sub>SO<sub>4</sub> pellet in lysis buffer (use minimal volume so you have a reasonable load volume for the phenyl sepharose column). After allowing as much of the precipitate as possible to resolubilize (some material typically remains insoluble), spin the sample for 1 hr at 12K in Sorvall RC5B centrifuge with the SA600 rotor. Keep the supernatent.
| |
| | |
| 8. Run samples of lysis supernatent and pellet, and (NH<sub>4</sub>)<sub>2</sub>SO<sub>4</sub> supernatents and pellets on an SDS-polyacrylamide gel to make sure you haven't left all the ClpX behind.
| |
| | |
| ===Phenyl sepharose column===
| |
| 1. Add (NH<sub>4</sub>)<sub>2</sub>SO<sub>4</sub> to the ClpX sample until the conductivity matches the conductivity of the phenyl sepharose equilibration buffer (buffer PS-A). Obviously, too much (NH<sub>4</sub>)<sub>2</sub>SO<sub>4</sub> at this step will precipitate the ClpX. | |
| | |
| 2. Equilibrate a HiLoad 16/10 phenyl sepharose high performance column (Amersham) with buffer PS-A, load sample, and wash column with buffer PS-A.
| |
| | |
| 3. Run gradient from 0–100% buffer PS-B. ClpX generally elutes half way through the gradient.
| |
| | |
| 4. Run a gel of the fractions and combine those that contain ClpX.
| |
| | |
| ===Q sepharose column===
| |
| 1. Buffer exchange combined phenyl sepharose fractions containing ClpX into buffer QS-A (dialyze, do '''not''' use a PD-10 column; ClpX sticks to PD-10s). Alternatively, dilute the ClpX sample to a conductivity equivalent to that of buffer QS-A.
| |
| *I took the dilution route and ended up with ~500 mL of sample, which I loaded onto the column using the peristaltic pump. This may or may not save you time versus an overnight dialysis step. [[User:Kathmc|Kathleen]]
| |
| | |
| 2. Equilibrate a HiLoad 16/10 Q sepharose high performance column (Amersham) with buffer QS-A, load sample, and wash column with buffer QS-A.
| |
| | |
| 3. Run gradient from 0–100% buffer QS-B. ClpX generally elutes around 300 mM KCl.
| |
| | |
| 4. Run gel and pool fractions that contain ClpX. Determine the concentration by UV absorbance (extinction coefficient @280 nm=84480 cm<sup>-1</sup>M<sup>-1</sup> for ClpX<sub>6</sub>). Aliquot and keep samples frozen at -80 ˚C. Some recommend only thawing a tube once, as multiple freeze/thaw cycles results in loss of activity.
| |
| | |
| ===Source 15Q column===
| |
| To concentrate the ClpX sample, run a smaller volume Source 15Q column (Amersham) with a steep gradient using the same buffers you used for the Q sepharose column. ClpX typically sticks to spin columns used for concentration, so you will lose protein if you try to concentrate your sample this way.
| |
| | |
| ===More columns...===
| |
| If you are unhappy with the purification at this point, you can try running a gel filtration column (S200, Amersham) and/or a hydroxylapatite column.
| |
| | |
| ===Buffers===
| |
| '''Lysis buffer'''
| |
| | |
| 50 mM Tris-HCl, pH 8.0
| |
| | |
| 100 mM KCl
| |
| | |
| 5 mM MgCl<sub>2</sub>
| |
| | |
| 5 mM DTT
| |
| | |
| 10% glycerol
| |
| | |
| 1 mM PMSF (make fresh!)
| |
| | |
| '''Bufer PS-A'''
| |
| | |
| 50 mM Na-phosphate buffer, pH 7.5
| |
| | |
| 2 mM DTT
| |
| | |
| 10% glycerol
| |
| | |
| 0.5 M (NH<sub>4</sub>)<sub>2</sub>SO<sub>4</sub>
| |
| | |
| '''Buffer PS-B'''
| |
| | |
| Same as PS-A, but with no (NH<sub>4</sub>)<sub>2</sub>SO<sub>4</sub>.
| |
| | |
| '''Buffer QS-A'''
| |
| | |
| Same as lysis buffer, but with no PMSF.
| |
| | |
| '''Buffer QS-B'''
| |
| | |
| Same as QS-A, but with 1 M KCl (or you could use NaCl here).
| |
| | |
| | |
| ==Who to ask about this protocol==
| |
| Greg, Andreas, [[user:kathmc|Kathleen]]
| |